10302/2/1 | Honeywell Watchdog Repeater 24Vdc/5Vdc
PLC
- Brand: Honeywell
- Part Number:
10302/2/1 - Availability: Ask for quote
Honeywell 10302/2/1 watchdog repeater ensures reliable power monitoring in redundant configurations. 24Vdc/5Vdc, 0.1mA input, CE/TÜV/UL approved.
Product Details
Reliable Power Monitoring with the Honeywell 10302/2/1 Watchdog Repeater
In industrial automation, redundant power supply configurations are critical for maintaining system uptime. However, without proper monitoring, a silent failure in one power supply can lead to unexpected downtime. The Honeywell 10302/2/1 watchdog repeater (WDR) is engineered to address this challenge by providing a reliable watchdog signal in complex power architectures. Whether you’re upgrading an existing system or building a new one, this genuine Honeywell part ensures that your 5 Vdc and 24 Vdc rails are continuously monitored, preventing costly interruptions.

Key Features and Technical Specifications
- Manufacturer: Honeywell, a trusted name in industrial automation.
- Product type: Watchdog repeater (WDR) for redundant power configurations.
- Power requirements: 5 Vdc at 35 mA (without WDROUT output current) and 24 Vdc at 25 mA.
- WDG1 + WDG2 input current: 0.1 mA, ensuring minimal load on monitoring circuits.
- Space requirements: 4 TE, 3 HE (4 HP, 3U), optimizing rack space.
- Module code: holes A5, A9; Rack code: large pins A5, A9 for secure mounting.
- Software version: ≥ 3.00, compatible with modern control systems.
- Approvals: CE, TÜV, UL, meeting international safety standards.
- Weight: 0.12 kg, lightweight yet robust.
The 10302/2/1 stands out for its low input current of 0.1 mA, which minimizes power consumption while maintaining accurate monitoring. This is particularly beneficial in systems where energy efficiency is a priority.
When to Use the Watchdog Repeater
The watchdog repeater is essential in several configurations to ensure reliable operation:
- Multiple-PSU configurations: For each subsequent 24 Vdc to 5 Vdc power supply unit (e.g., PSU 2, 3, 4).
- When the 24 Vdc is supplied via an M24-20 HE or M24-12 HE power supply.
- If the 24 Vdc supply can provide voltages exceeding 31.0 Vdc (maximum output must be less than 37 Vdc under fault conditions).
- When the required watchdog current exceeds 900 mA.
- In configurations combining redundant and non-redundant I/O, to create the watchdog output for non-redundant I/O modules.
- With redundant Central Parts and non-redundant I/O, to monitor the 5 Vdc supply when no other monitoring is present.
By incorporating the 10302/2/1, engineers can avoid the pitfalls of unmonitored power supplies, such as undetected failures that could lead to production losses.

Comparison with Similar Products
When selecting a watchdog repeater, it’s important to consider key parameters. Below is a comparison of the Honeywell 10302/2/1 with typical alternatives:
- Operating temperature: The 10302/2/1 is designed for industrial environments; refer to the official datasheet for the exact range. Many competitors offer similar ranges, but Honeywell’s robust design ensures reliability.
- Input voltage: The module accepts 5 Vdc and 24 Vdc, a common requirement in redundant systems. Some alternatives may only support one voltage, requiring additional components.
- Power supply: Low power consumption (35 mA at 5 Vdc, 25 mA at 24 Vdc) makes it energy-efficient compared to some higher-draw repeaters.
- Communication protocol: The 10302/2/1 provides hardwired watchdog signals; for integration into fieldbus networks, an external gateway may be needed. Competitors with built-in protocols might offer easier integration but at a higher cost.
- Approvals: CE, TÜV, UL certifications ensure global acceptance, whereas some alternatives may lack one or more.
Overall, the Honeywell 10302/2/1 offers a balanced combination of reliability, low power consumption, and broad certification, making it a value-for-money choice for system integrators.
Installation and Setup
Installing the 10302/2/1 is straightforward thanks to its standard 4 TE, 3 HE form factor. Mount the module in a compatible rack using the large pins at positions A5 and A9. Ensure that the 5 Vdc and 24 Vdc power connections are secure and that the watchdog input lines (WDG1 and WDG2) are correctly wired. The module requires software version 3.00 or higher for full functionality. For detailed wiring diagrams, refer to the official Honeywell documentation.
Maintenance and Reliability
The 10302/2/1 is designed for long-term reliability with minimal maintenance. Regular inspections should include checking for secure mounting, verifying power supply voltages, and ensuring that the watchdog outputs are functioning. Since the module operates in industrial environments, it is advisable to keep it free from dust and moisture. With its low power consumption and robust construction, the 10302/2/1 contributes to reduced downtime and extended service life, aligning with cost-benefit goals.
Compatibility and Integration
The 10302/2/1 integrates seamlessly with Honeywell’s automation systems and is compatible with a wide range of power supplies and I/O modules. When integrating into fieldbus networks such as PROFINET or EtherNet/IP, note that the watchdog repeater provides hardwired signals; an external gateway or connection module may be required. Always confirm cable and gateway compatibility with your supplier to ensure smooth integration.
Frequently Asked Questions
Q: What is the primary function of the Honeywell 10302/2/1 watchdog repeater?
A: The 10302/2/1 is a watchdog repeater designed for use in redundant power supply configurations. It monitors the 5 Vdc output and provides a watchdog signal to ensure proper operation of downstream modules, particularly in systems with multiple PSUs or mixed redundant/non-redundant I/O.
Q: What are the power requirements for the 10302/2/1?
A: The module requires 5 Vdc at 35 mA (excluding WDROUT output current) and 24 Vdc at 25 mA. The WDG1 and WDG2 input current is 0.1 mA.
Q: In which configurations is the watchdog repeater required?
A: It is required in multiple-PSU setups (for each subsequent 24 Vdc to 5 Vdc PSU), when using M24-20 HE or M24-12 HE power supplies, when supply voltage can exceed 31.0 Vdc, when watchdog current exceeds 900 mA, and in configurations combining redundant and non-redundant I/O or redundant central parts with non-redundant I/O.
Q: What approvals does the 10302/2/1 hold?
A: The module is CE, TÜV, and UL approved, ensuring compliance with international safety and quality standards.
Product Support & Availability
The Honeywell 10302/2/1 is in stock and ready to ship from Mronexus. As your one-stop sourcing base for genuine industrial automation parts, we offer fast delivery and competitive prices. Contact Mronexus for genuine industrial automation parts and ensure your systems run reliably.
Unmatched Customer Service
- After Hours Shipping
- Real Time Order Tracking
- Flexible Delivery Options
- Intact Technical Supports