1747-DCM/A | Allen-Bradley SLC 500 RIO Adapter Module
PLC
- Brand: Allen-Bradley
- Part Number:
1747-DCM/A - Availability: Ask for quote
The Allen-Bradley 1747-DCM/A is a Direct Communication Module (RIO adapter) for SLC 500 systems, enabling reliable data exchange between supervisory PLCs and distributed processors via Remote I/O.
Product Details
Product Overview
The Allen-Bradley 1747-DCM/A is a Direct Communication Module (DCM) designed for the SLC 500 family. It functions as a Remote I/O (RIO) adapter, allowing SLC 500 processors to exchange data with supervisory PLCs such as the PLC-5 over an RIO communication link. This module is ideal for distributed control architectures where reliable, deterministic data transfer is critical. As part of the Bulletin 1747 series, the 1747-DCM/A is a single-slot module that mounts in any 1746 chassis (except slot 0, which is reserved for the processor or 1747-ASB adapter). It draws 360 mA at 5V DC from the backplane and supports RIO baud rates of 57.6, 115.2, and 230.4 kbps. Configuration is straightforward via DIP switches, and the module uses a 6-pin Phoenix connector for field wiring with Belden 9463 cable. Although the SLC 500 platform is now obsolete, the 1747-DCM/A remains a vital component for maintaining existing systems. Mronexus offers genuine industrial automation parts at competitive prices, providing a reliable source for this and other legacy modules. Our worldwide shipping and fast delivery from stock ensure minimal downtime for your operations.

Key Technical Specifications
- Operating Temperature: 0 to 60 °C (32 to 140 °F) – suitable for standard industrial environments.
- Backplane Power: 360 mA @ 5V DC – ensures compatibility with 1746 chassis power budgets.
- Communication Protocol: Remote I/O (RIO) – enables deterministic data exchange with supervisory PLCs.
- Baud Rates: 57.6, 115.2, 230.4 kbps – selectable via DIP switches for flexible network design.
- Connector: 6-pin Phoenix – provides secure, removable field wiring termination.
- Cable: Belden 9463 – industry-standard twinaxial cable for RIO networks.
- Maximum Adapters: Up to 32 per RIO link – supports large distributed systems.
- Slot Requirements: Single slot in 1746 chassis (not slot 0) – easy integration into existing racks.
- Hot-Swap: Not supported – ensure power is removed before installation or wiring.
For specifications not listed here, refer to the official Allen-Bradley datasheet.
Applications and Use Cases
The 1747-DCM/A excels in legacy SLC 500 systems that require reliable data transfer between supervisory and distributed processors. Common applications include manufacturing lines where a central PLC-5 coordinates multiple SLC 500 stations, such as in automotive assembly or material handling. In water treatment plants, the module can link remote pump stations to a central control room, ensuring timely updates without scanning local I/O. Another key use case is in retrofit projects where existing SLC 500 infrastructure must be integrated with newer supervisory systems. The module’s ability to handle up to 32 adapters per link makes it suitable for large-scale distributed control. However, note that the SLC 500 platform is discontinued; for new designs, consider migrating to CompactLogix 5370/5380 with EtherNet/IP or ControlNet adapters. For maintenance and spare parts, Mronexus is your one-stop sourcing base for genuine Allen-Bradley components.
Installation and Setup
Installing the 1747-DCM/A requires careful attention to safety and configuration. Always remove power from the chassis before inserting or removing the module. The module can be placed in any slot except slot 0, which is reserved for the processor or 1747-ASB adapter. Use the DIP switches to set the RIO baud rate and other parameters according to your network design. Field wiring should be made to the 6-pin Phoenix connector using Belden 9463 cable, ensuring proper termination and shielding to minimize noise. The RIO link should be daisy-chained from the supervisory PLC to each adapter, with terminators at both ends. After wiring, verify connections and then apply power. Configure the supervisory PLC to recognize the adapter and map the data exchange. For detailed instructions, consult the SLC 500 documentation.
Compatibility and Integration
The 1747-DCM/A is compatible with SLC 500 processors and 1746 chassis, as well as PLC-5 and other supervisory PLCs that support RIO communication. It integrates seamlessly into existing RIO networks, but note that RIO is a legacy protocol; modern systems may require gateways for Ethernet-based networks. When integrating with fieldbus systems like PROFINET or EtherNet/IP, an external gateway or connection module may be necessary. Confirm cable and gateway compatibility with your supplier. Mronexus offers a range of communication modules and can assist with selecting the right components for your application.
Maintenance and Reliability
To ensure long-term reliability, periodic inspections are recommended. Check the module’s seating in the chassis and the integrity of field wiring, especially in high-vibration environments. The operating temperature range of 0 to 60 °C should be maintained; ensure adequate ventilation and avoid mounting near heat sources. Since the module is not hot-swappable, always follow lockout/tagout procedures during maintenance. Common failure modes include communication errors due to cable damage or incorrect termination, which can be mitigated by using quality Belden 9463 cable and proper installation. Spare modules should be kept on hand to minimize downtime, as the SLC 500 platform is obsolete and replacements may become scarce. Mronexus provides fast delivery from stock to support your maintenance needs.
Frequently Asked Questions
Q: What is the primary function of the 1747-DCM/A?
A: The 1747-DCM/A is a Direct Communication Module that acts as a Remote I/O (RIO) adapter for SLC 500 systems. It enables data exchange between a supervisory PLC (e.g., PLC-5) and distributed SLC 500 processors over an RIO link, passing supervisory data without scanning local I/O.
Q: What communication rates does the 1747-DCM/A support?
A: The module supports RIO baud rates of 57.6, 115.2, and 230.4 kbps, configurable via DIP switches. It uses Belden 9463 cable and a 6-pin Phoenix connector for reliable network integration.
Q: Can the 1747-DCM/A be hot-swapped?
A: No, the module is not hot-swappable. Do not install, remove, or wire it while power is applied. Always follow proper lockout/tagout procedures to avoid damage or injury.
Q: Is the 1747-DCM/A still available for purchase?
A: The 1747-DCM/A is discontinued as part of the SLC 500 platform. However, genuine surplus and refurbished units may be available from specialized suppliers like Mronexus. Contact us for current stock and alternatives.
Product Support and Availability
Mronexus maintains a stock of genuine Allen-Bradley 1747-DCM/A modules and other legacy automation parts. We offer worldwide shipping with fast delivery to help you minimize downtime. Contact Mronexus for genuine industrial automation parts and expert support.
Unmatched Customer Service
- After Hours Shipping
- Real Time Order Tracking
- Flexible Delivery Options