111-912-000-011-A1-B6-E5000-F0-G0-H05 | Vibro Meter Proximity Sensor, 5m Cable
PLC
- Brand: Vibro Meter
- Part Number:
111-912-000-011-A1-B6-E5000-F0-G0-H05 - Availability: Ask for quote
Vibro Meter TQ912 proximity measuring system with 5m integral cable, 3/8″-24UNF thread, IP68 rating, and -40 to 180°C operating range. Ideal for API 670 machinery protection.
Product Details
Reliable Non-Contact Measurement for Critical Machinery
In the world of industrial automation, unplanned downtime is the enemy. For maintenance engineers, the challenge is finding a proximity measuring system that delivers consistent, accurate data without constant babysitting. The 111-912-000-011-A1-B6-E5000-F0-G0-H05 from Vibro Meter (Meggitt) is engineered to meet that challenge head-on. This TQ912 proximity sensor is a non-contact eddy-current system designed for harsh environments, offering a 5-meter integral cable and a robust 3/8″-24UNF threaded body. Whether you’re monitoring shaft vibration on a turbine or position feedback on a reciprocating compressor, this sensor provides the reliability you need to keep operations running smoothly.

Key Features and Technical Specifications
- Operating Temperature (Sensor): -40 to 180°C continuous, with short-term survival up to 220°C for 2 hours.
- Input Voltage: Requires high-frequency power source from an IQS900 signal conditioner.
- Power Supply: Voltage or current output with short-circuit protection; current transmission up to 1 km.
- Communication Protocol: Analog voltage/current output; no digital protocol, but diagnostic circuitry available.
- Measurement Range: Linear range of 2 or 4 mm (system dependent).
- Frequency Response: DC to 20 kHz (-3 dB).
- Protection Rating: Sensor head rated IP68 for dust and water immersion.
- Body Thread: 3/8″-24UNF for secure mounting.
- Integral Cable Length: 5000 mm ±500 mm, FEP-covered coaxial cable.
- Weight: 0.22 kg.
The temperature-compensated design ensures measurement drift of less than 5% across -30 to 150°C, a critical advantage in processes with varying thermal conditions. The sensor’s stainless-steel body (AISI 316L) and PPS thermoplastic tip resist corrosion and mechanical wear, while the IP68 rating guarantees protection against ingress in washdown or outdoor installations.
Applications and Use Cases
This proximity sensor excels in condition monitoring and protection systems across industries. In oil and gas, it’s commonly used for API 670 compliant vibration monitoring on centrifugal compressors and gas turbines. The 5-meter cable length provides flexibility for routing through complex machinery skids, while the 3/8″-24UNF thread ensures compatibility with standard mounting brackets. In power generation, the sensor’s high-temperature tolerance makes it suitable for steam turbine bearing vibration measurement. Additionally, the optional diagnostic circuitry (when paired with an IQS900 signal conditioner) can detect sensor, cabling, or signal conditioner faults, enabling predictive maintenance and reducing unexpected failures. For functional safety applications, the system supports SIL 2 (IEC 61508) and Cat 1 PL c (ISO 13849) when used with appropriate signal conditioners.
Installation and Setup Best Practices
Proper installation is key to reliable performance. The sensor should be mounted using the 3/8″-24UNF thread, ensuring the tip is perpendicular to the target surface. Maintain the recommended gap based on the linear range (2 or 4 mm) and calibrate the system at +23°C ±5°C for optimal accuracy. The self-locking miniature coaxial connectors should be hand-tightened until locked—do not over-torque. When routing the integral cable, avoid sharp bends and secure it to prevent strain. For hazardous areas, ensure the Ex-rated version is used and follow local regulations. The sensor head’s IP68 rating allows for washdown, but the connector interface should still be protected from prolonged immersion.
Maintenance and Reliability
From a maintenance engineer’s perspective, this sensor is designed for low maintenance. The non-contact eddy-current principle means no wear parts, and the stainless-steel construction resists corrosion. Regular inspection should focus on cable integrity (check for cuts or abrasion) and connector tightness. In high-vibration environments, verify mounting torque periodically. The temperature-compensated design reduces drift, so recalibration is rarely needed unless the sensor or target is replaced. Diagnostic circuitry, when used, can provide early warning of degradation, allowing planned interventions. With a frequency response up to 20 kHz, the sensor captures high-frequency events like gear mesh or bearing defects, making it a valuable tool for predictive maintenance programs.
Compatibility and Integration
The 111-912-000-011-A1-B6-E5000-F0-G0-H05 is designed to work seamlessly with Vibro Meter’s IQS900 signal conditioner, which provides the necessary high-frequency power and processes the output. The system supports voltage or current output, with current transmission over distances up to 1 km, ideal for remote monitoring. For integration into PLC or DCS systems, the analog output can be wired to standard input cards. Note that this sensor does not natively support fieldbus protocols like PROFINET or EtherNet/IP; for such networks, an external gateway or connection module may be required. Always confirm cable and gateway compatibility with the supplier. The removable screw-terminal connectors on the IQS900 simplify wiring and maintenance.
Frequently Asked Questions
Q: What is the maximum operating temperature for the sensor?
A: The sensor operates continuously from -40 to 180°C, with short-term survival up to 220°C for a maximum of 2 hours. The cabling and connectors are rated for -40 to 200°C.
Q: Can this sensor be used in hazardous areas?
A: Yes, Ex-certified versions are available. The standard version (Environment A=1) is for non-hazardous areas. For explosive atmospheres, specify the appropriate Ex version and consult the datasheet for temperature ratings.
Q: What is the measurement range and frequency response?
A: The linear measurement range is 2 or 4 mm (depending on system calibration), and the frequency response is DC to 20 kHz (-3 dB), suitable for high-speed machinery monitoring.
Q: How do I connect the sensor to my control system?
A: The sensor requires an IQS900 signal conditioner, which provides power and outputs a voltage or current signal. This can be wired to PLC analog inputs. For fieldbus integration, an external gateway is needed.
Product Support and Availability
Mronexus stocks the 111-912-000-011-A1-B6-E5000-F0-G0-H05 and is ready to ship worldwide. As your one-stop sourcing base for genuine industrial automation parts, we ensure fast delivery and competitive pricing. Contact Mronexus for genuine industrial automation parts and technical support.
Unmatched Customer Service
- After Hours Shipping
- Real Time Order Tracking
- Flexible Delivery Options
- Intact Technical Supports