3RV6021-4CA15 | Siemens SIRIUS 3RV2 Circuit Breaker 11-16A
Circuit Breaker
- Brand: Siemens
- Part Number:
3RV6021-4CA15 - Availability: Ask for quote
Siemens 3RV6021-4CA15 SIRIUS 3RV2 motor protection circuit breaker, 11-16A, Class 10, 55kA breaking capacity. Reliable overload and short-circuit protection for industrial motors.
Product Details
When Nuisance Trips Halt Production: The 3RV6021-4CA15 Solution
A packaging line repeatedly tripped its aging motor starter during peak load, causing unplanned downtime. The root cause was a circuit breaker with a mismatched trip class and insufficient breaking capacity. The Siemens 3RV6021-4CA15 from the SIRIUS 3RV2 series solves this with a 11–16 A adjustable overload release, Class 10 trip curve, and 55 kA short-circuit breaking capacity at 400 V. This motor protection circuit breaker (MPCB) delivers reliable, genuine protection for three-phase motors up to 7.5 kW at 400 V AC-3. As your one-stop sourcing base for industrial automation parts, Mronexus supplies this genuine Siemens breaker at competitive prices, ready to ship from stock.

Key Features & Technical Specifications
- Operating temperature: -20 °C to +60 °C during operation; storage and transport rated -50 °C to +80 °C.
- Input voltage: Rated operating voltage 690 V AC; rated impulse withstand voltage 6 kV.
- Power supply: 3-pole main circuit; rated service power 7.5 kW at 400 V AC-3; typical total power loss 8.3 W.
- Communication protocol: No native fieldbus interface; auxiliary contacts provide hardwired status signals for PLC integration.
- Overload release: Adjustable 11–16 A, Class 10 trip characteristic for motor protection.
- Short-circuit breaking capacity (Icu): 55 kA at 400 V, 10 kA at 500 V, 4 kA at 690 V.
- Auxiliary switch: Transverse-mounted auxiliary switch included; 2 A at 24 V AC-15, 0.5 A at 230 V AC-15.
- Mechanical endurance: 100,000 operating cycles; 15 operations per hour at AC-3.
- Dimensions: 45 mm (W) × 97 mm (H) × 91 mm (D); mounts on 35 mm DIN rail per EN 60715.
- Terminals: Screw-type for main and auxiliary circuits; accepts solid and finely stranded conductors up to 10 mm² (main) and 2.5 mm² (auxiliary).
The Class 10 trip curve is particularly effective for motors with high starting currents, preventing nuisance trips while ensuring rapid disconnection during overloads.
Applications & Use Cases
The 3RV6021-4CA15 is engineered for motor protection in demanding industrial environments. Typical applications include:
- Pump and fan motors in HVAC and water treatment plants, where stable operation is critical.
- Conveyor drives in material handling systems, requiring frequent starts and stops.
- Compressor motors in manufacturing processes, where overload protection prevents costly rewinding.
- Machine tool spindles and auxiliary drives in metalworking, benefiting from the compact S0 frame size.
In a recent retrofit project, a food processing plant replaced outdated breakers with the 3RV6021-4CA15 to address frequent tripping during washdown cycles. The IP20 finger-safe design and wide operating temperature range ensured reliable performance despite humidity and temperature fluctuations.

Installation & Setup
Mounting the 3RV6021-4CA15 is straightforward: snap it onto a 35 mm DIN rail per EN 60715, and connect main conductors to the top and bottom screw terminals. The breaker can be installed in any position. For motor protection, set the adjustable overload release to the motor’s full-load current (within 11–16 A). Ensure proper torque on terminal screws to avoid overheating. The transverse auxiliary switch provides a changeover contact for status monitoring or interlocking; connect it to your PLC or control circuit using the specified wire sizes (0.5–2.5 mm²). Always follow local electrical codes and verify that the short-circuit breaking capacity meets or exceeds the available fault current at the installation point.
Compatibility & Integration
The 3RV6021-4CA15 integrates seamlessly with Siemens SIRIUS 3RV2 accessories, including auxiliary releases, terminal covers, and busbars. It is compatible with standard 35 mm DIN rail systems and can be combined with contactors (e.g., SIRIUS 3RT) for complete motor starters. The auxiliary switch offers hardwired signaling to PLCs, HMIs, or monitoring relays. For network integration, the breaker itself does not support fieldbus protocols; however, its auxiliary contacts can be wired to remote I/O modules or a PLC’s digital inputs. When integrating into PROFINET or EtherNet/IP networks, an external gateway or connection module may be required. Confirm cable and gateway compatibility with your supplier.
Maintenance & Reliability
The 3RV6021-4CA15 is designed for long service life with minimal maintenance. Inspect terminals periodically for tightness, especially in high-vibration environments. The mechanical endurance of 100,000 operating cycles ensures years of reliable operation under normal duty. Keep the breaker clean and free of dust to maintain IP20 protection. Operating temperature range of -20 °C to +60 °C suits most industrial settings; avoid exposure to excessive humidity or corrosive atmospheres. The trip indicator (optional) helps diagnose overload events quickly, reducing troubleshooting time. By choosing genuine Siemens components, you minimize the risk of premature failure and extend equipment life, delivering value-for-money over the long term.
FAQ
Q: What is the difference between the 3RV6021-4CA15 and the 3RV6021-4AA15?
A: The 3RV6021-4CA15 includes a transverse auxiliary switch, while the 3RV6021-4AA15 does not. Both share the same 11–16 A overload range and Class 10 trip curve.
Q: Can this breaker be used for single-phase motors?
A: Yes, although it is a 3-pole device, it can protect single-phase motors by wiring the load across two poles and leaving the third unused, or by using a 2-pole configuration. Ensure the overload setting matches the motor’s full-load current.
Q: What is the maximum short-circuit current this breaker can interrupt at 400 V?
A: The rated breaking capacity (Icu) is 55 kA at 400 V AC, suitable for most industrial distribution systems. Verify coordination with upstream protection devices.
Q: Does the 3RV6021-4CA15 support communication protocols like PROFINET?
A: No, it does not have a native fieldbus interface. However, its auxiliary contacts can be connected to a PLC or remote I/O for monitoring. For network integration, an external gateway may be required.
Q: What is the operating temperature range?
A: The breaker operates reliably from -20 °C to +60 °C. Storage and transport temperatures range from -50 °C to +80 °C.
Product Support & Availability
The Siemens 3RV6021-4CA15 is in stock and ready to ship from Mronexus. As your one-stop sourcing base for genuine industrial automation parts, we offer fast worldwide delivery and competitive pricing. Contact Mronexus for genuine industrial automation parts and technical support.
Unmatched Customer Service
- After Hours Shipping
- Real Time Order Tracking
- Flexible Delivery Options
- Intact Technical Supports