3RW4436-6BC44 | Siemens SIRIUS Soft Starter 162A 90kW
PLC
- Brand: Siemens
- Part Number:
3RW4436-6BC44 - Availability: Ask for quote
Siemens 3RW4436-6BC44 SIRIUS soft starter: 162A, 90kW at 400V, inside-delta 281A/160kW. Reliable motor control with genuine parts from Mronexus.
Product Details
Introduction: The Evolution of Motor Control
In the early days of industrial automation, starting a large motor meant enduring the violent jolt of direct-on-line (DOL) starting—a sudden surge of current that stressed windings, couplings, and the entire electrical network. As plants grew larger and motors more powerful, engineers sought a smoother way. The soft starter emerged as a reliable solution, gradually replacing crude electromechanical methods with solid-state control. Today, the Siemens SIRIUS 3RW4436-6BC44 stands as a testament to that evolution, offering precise, reliable soft starting for motors up to 90 kW in standard configuration and 160 kW in inside-delta. At Mronexus, we supply this genuine industrial automation part at competitive prices, ensuring your operations benefit from the latest in motor control technology.

Product Overview and Key Features
The 3RW4436-6BC44 is a high-feature soft starter from Siemens’ renowned SIRIUS series. It combines advanced thyristor control with integrated bridging contacts to deliver smooth acceleration and deceleration, reducing mechanical wear and extending motor life. Designed for three-phase squirrel cage motors, it supports both standard and inside-delta circuits, providing flexibility for various power requirements. Key technical specifications include:
- Operating voltage: 200–460 V AC (standard circuit), with tolerance -15% to +10%.
- Rated operating current: 162 A at 40°C (standard); 281 A at 40°C (inside-delta).
- Motor power: 90 kW at 400 V (standard); 160 kW at 400 V (inside-delta).
- Control supply voltage: 230 V AC, 50/60 Hz.
- Operating frequency: 50/60 Hz with ±10% tolerance.
- Ambient temperature: -25°C to +60°C during operation (derating above 40°C).
- Protection class: IP00 (requires installation in a suitable enclosure).
- Communication: No integrated fieldbus; auxiliary contacts for status signaling.
- Dimensions (WxHxD): 170 x 200 x 270 mm.
A standout feature is the inside-delta circuit capability, which allows the soft starter to handle motors up to 160 kW while only carrying 58% of the motor current—ideal for retrofitting high-power applications without upgrading the starter frame size. This design not only saves space but also reduces cost.
Applications and Use Cases
The 3RW4436-6BC44 excels in applications where controlled motor starting is critical. In water treatment plants, it smoothly accelerates large pumps, preventing water hammer and pipe stress. For HVAC systems, it reduces belt wear and noise during fan start-up. In conveyor systems, the adjustable current limitation ensures gentle handling of materials, avoiding jams and product damage. The inside-delta configuration is particularly beneficial for heavy-duty compressors and crushers, where high starting torque is required without excessive current draw. With its robust design and wide temperature range, this soft starter is equally at home in food processing, mining, and automotive manufacturing.

Installation and Setup
Proper installation is key to reliable performance. The 3RW4436-6BC44 features screw terminals for main and control connections, accommodating conductor cross-sections from 16 to 70 mm² (main) and 0.5 to 2.5 mm² (auxiliary). Mount it vertically on a flat surface, maintaining clearances: 100 mm above, 75 mm below, and 5 mm to the sides for adequate cooling. The soft starter can be tilted ±22.5° forward or backward for optimal viewing of the display. Ensure the control supply is a stable 230 V AC source. For integration into a network, note that this device does not include a fieldbus interface; however, its auxiliary contacts (3 NO, 1 changeover) can be wired to a PLC for status monitoring. If you require PROFINET or EtherNet/IP connectivity, an external gateway or connection module may be needed—consult Mronexus for compatible accessories.
Maintenance and Reliability
Designed for long service life, the 3RW4436-6BC44 requires minimal maintenance. Periodically inspect the cooling vents for dust accumulation, especially in harsh environments. Check terminal tightness annually to prevent overheating. The integrated bypass contacts reduce thermal stress during continuous operation, enhancing reliability. With an operating temperature range up to 60°C and storage from -25°C to +80°C, it withstands challenging conditions. For maximum uptime, consider the cost savings from reduced downtime and extended motor life—a direct benefit of soft starting. Mronexus stocks genuine Siemens soft starters, ensuring fast delivery and value-for-money.
Compatibility and Integration
The 3RW4436-6BC44 is compatible with standard three-phase motors and can be integrated into existing control panels. It supports both standard and inside-delta configurations, making it versatile for various motor setups. The auxiliary contacts allow for hardwired signaling to PLCs or HMIs. For advanced communication, an external gateway can be added to interface with higher-level systems. Always verify cable lengths—up to 500 m is permissible—and use shielded cables in electrically noisy environments. When planning your integration, rely on Mronexus for genuine parts and technical guidance.
Frequently Asked Questions
Q: What is the maximum operating temperature of the 3RW4436-6BC44?
A: The soft starter can operate at ambient temperatures up to 60°C. However, derating applies above 40°C: rated current decreases to 145A at 50°C and 125A at 60°C. Ensure adequate ventilation in the enclosure.
Q: Can the 3RW4436-6BC44 be used in an inside-delta circuit?
A: Yes, it supports inside-delta connection, allowing motor ratings up to 281A and 160kW at 400V. This configuration reduces the current load on the soft starter and is ideal for high-power motors.
Q: What control voltage does the 3RW4436-6BC44 require?
A: The control electronics require a 230V AC supply at 50 or 60Hz. Ensure the control voltage is within -15% to +10% tolerance for reliable operation.
Q: Does the soft starter include motor overload protection?
A: Yes, it features intrinsic device protection and motor overload protection with adjustable current settings from 32A upwards. It also supports evaluation of thermal resistor motor protection (PTC).
Product Support and Availability
Mronexus is your one-stop sourcing base for genuine industrial automation parts, including the Siemens 3RW4436-6BC44 soft starter. We maintain stock for fast delivery worldwide, ensuring you get the parts you need without delay. Our team provides technical support to help you integrate and maintain your equipment. Contact Mronexus for genuine industrial automation parts at competitive prices.
Unmatched Customer Service
- After Hours Shipping
- Real Time Order Tracking
- Flexible Delivery Options
- Intact Technical Supports