STBNDN1010 | Schneider Electric DeviceNet NIM for Advantys STB
PLC
- Brand: Schneider Electric
- Part Number:
STBNDN1010 - Availability: Ask for quote
Genuine Schneider Electric STBNDN1010 DeviceNet network interface module for Advantys STB. Supports up to 32 I/O modules, 24V DC supply, IP20. In stock at Mronexus.
Product Details
Is Your Legacy DeviceNet Network Still Reliable?
If you maintain an Advantys STB island with a DeviceNet interface, you know the challenge: keeping proven automation systems running when the original network interface module is discontinued. The Schneider Electric STBNDN1010 is a basic network interface module (NIM) that connects up to 32 I/O modules to a DeviceNet network. While the product has been superseded by the Modicon X80 range, genuine units remain available for existing installations — and that can mean the difference between a quick repair and a costly redesign.

Product Overview: STBNDN1010 DeviceNet NIM
The STBNDN1010 is part of the Advantys STB series, a distributed I/O platform known for its modularity and open network compatibility. This NIM acts as the head of an island, managing communication between the I/O modules and a DeviceNet master. It is a 24V DC powered module with a 5-pin DeviceNet connector, designed for panel mounting. The module measures 128.3 × 70 × 40 mm and weighs 0.145 kg, making it compact enough for dense control cabinets.
Key Technical Specifications
- Protocol: DeviceNet — a widely used fieldbus in automotive, material handling, and process industries.
- Supply voltage: 24V DC, the standard for industrial control systems.
- I/O capacity: Supports up to 32 addressable I/O modules per island, providing scalability for medium to large systems.
- Connector: 5-pin DeviceNet connector for network and power.
- Protection rating: IP20 — suitable for installation inside enclosures.
- Dimensions: 128.3 × 70 × 40 mm (H×W×D).
- Weight: 0.145 kg.
- Hot-swap: Not supported — modules must be replaced with power removed.
- Debug port: No RS232 debug port.
Note: Operating and storage temperature ranges are not specified in the available documentation. Refer to the official Schneider Electric datasheet for environmental limits.
DeviceNet Integration and Compatibility
The STBNDN1010 integrates seamlessly into DeviceNet networks, allowing Advantys STB I/O modules to communicate with a wide range of PLCs and controllers. DeviceNet is known for its robust performance in noisy industrial environments, and the STBNDN1010 leverages this reliability. The module supports up to 32 I/O modules, which can include digital and analog inputs/outputs, relays, and specialty modules.
Integration Note: When wiring into a DeviceNet network, ensure proper termination and use of shielded twisted-pair cable. Depending on your network architecture, an external gateway or connection module may be required. Confirm cable and gateway compatibility with your supplier before commissioning.
Installation and Setup
Installing the STBNDN1010 is straightforward for engineers familiar with Advantys STB systems. The module snaps onto a DIN rail and connects to the backplane. The 5-pin DeviceNet connector provides both communication and power. Because the STBNDN1010 does not support hot-swap, always disconnect power before inserting or removing the NIM or any I/O module. Set the DeviceNet node address and baud rate using the rotary switches on the front panel (refer to the manual for details). Ensure the island is properly grounded and that the 24V DC supply is stable and within tolerance.
Maintenance and Reliability
While the STBNDN1010 is a solid-state device with no moving parts, regular inspection is recommended to maintain reliability. Check the DeviceNet connector for tightness and corrosion, and verify that the IP20 enclosure is free of dust and debris. Since the module is discontinued, stocking spare units is a prudent strategy to minimize downtime. Mronexus offers genuine STBNDN1010 modules at competitive prices, providing a cost-effective alternative to migrating to a new platform.
Common Issues and Troubleshooting
Typical issues with DeviceNet NIMs include communication failures due to incorrect baud rate, faulty cabling, or power supply problems. If the network LED indicates an error, verify the node address and baud rate settings, check cable continuity, and ensure the 24V DC supply is within specification. If the module fails to power up, inspect the backplane connections. For persistent issues, refer to the official Schneider Electric documentation or contact Mronexus for technical guidance.
Frequently Asked Questions
Q: What is the maximum number of I/O modules that can be connected to the STBNDN1010?
A: The STBNDN1010 supports up to 32 addressable I/O modules per island, making it suitable for medium to large distributed I/O systems.
Q: Does the STBNDN1010 support hot-swap replacement of modules?
A: No, the STBNDN1010 does not support hot-swap. The island must be powered down before replacing modules. Plan maintenance windows accordingly.
Q: What is the operating temperature range of the STBNDN1010?
A: The operating temperature range is not specified in the available documentation. Please refer to the official Schneider Electric datasheet or contact Mronexus for assistance.
Q: Is the STBNDN1010 still available for purchase?
A: The STBNDN1010 is discontinued and superseded by the Modicon X80 range. However, Mronexus maintains stock of genuine legacy parts for existing installations. Contact us for availability.
Availability and Support
Mronexus stocks the STBNDN1010 and other Advantys STB components for fast delivery. As your one-stop sourcing base for industrial automation parts, we provide genuine Schneider Electric products at competitive prices. Whether you need a single replacement or a bulk order, our team is ready to assist. Contact Mronexus for genuine industrial automation parts and keep your DeviceNet network running reliably.
Unmatched Customer Service
- After Hours Shipping
- Real Time Order Tracking
- Flexible Delivery Options
- Intact Technical Supports