Skip to content
sales@mronexus.com Reply within 24 hours Worldwide shipping

150-F108NBRB | Allen-Bradley SMC Flex 108A Soft Starter

PLC

  • Brand: Allen-Bradley
  • Part Number: 150-F108NBRB
  • Availability: Ask for quote

The Allen-Bradley 150-F108NBRB SMC Flex Smart Motor Controller delivers reliable soft starting for 108A, 20-75Hp motors. Genuine parts at competitive prices from Mronexus.

Product Details

Reliable Soft Starting for Demanding Motor Applications

In industrial facilities, across-the-line starting of large induction motors creates mechanical stress, voltage dips, and premature wear on driven equipment. The Allen-Bradley 150-F108NBRB SMC Flex Smart Motor Controller addresses these pain points with a robust soft starter design rated for 108 A and motors from 20 to 75 Hp at 460 V AC. As part of the SMC Flex series, this controller combines proven thyristor power technology with intelligent control features, making it a reliable choice for pump, fan, and compressor applications. Mronexus supplies genuine Allen-Bradley parts at competitive prices, ensuring you receive authentic automation components with fast delivery from stock.

Figure 1: Front view of the Allen-Bradley 150-F108NBRB industrial automation component showing its physical design and enclosure.

Key Features & Technical Specifications

  • Controller rating: 108 A, 20–75 Hp at 460 V AC, 3-phase.
  • Rated operating voltage Ue: 200 V AC; operational range 200–480 V AC (-15%, +10%).
  • Control supply voltage: 24 V AC at 50/60 Hz or 24 V DC; input ON-state min. 85 V AC / 19.2 V DC.
  • Integrated overload protection with trip classes 10, 15, 20, and 30; trip current 117% of motor FLC.
  • Operating temperature (open): -5 to 50 °C (23 to 122 °F); storage down to -20 °C.
  • Communication: no native fieldbus; status indication via LEDs for stopped, starting, stopping, at speed, alarm, and fault.
  • Internal bypass reduces heat dissipation during run mode; steady-state heat dissipation 91 W with control and fan power.
  • Short-circuit protection: standard fuse, circuit breaker, or high-capacity time-delay Class CC/J/L; max fault current 70 kA.
  • DV/DT protection: RC snubber network for power circuit; transient protection via optional 220 J metal oxide varistors.
  • Dimensions: 196.4 mm W x 212.2 mm D x 443.7 mm H; weight 15 kg.

The SMC Flex controller stands out for its integrated bypass and advanced pump control option, which reduces water hammer and extends pump life. The programmable NO/NC auxiliary contacts (rated 5 A AC/DC) provide flexible status feedback to PLCs or control systems. With a repetitive peak inverse voltage rating of 1400 V per UL/CSA/NEMA, the power circuit is well-protected against voltage spikes, enhancing long-term reliability.

Applications & Use Cases

The 150-F108NBRB is ideally suited for starting and stopping three-phase AC motors in applications where mechanical shock and electrical disturbances must be minimized. Common use cases include centrifugal pumps in water treatment plants, where the pump control option smooths acceleration and deceleration to prevent pressure surges. In HVAC systems, the soft starter reduces belt and bearing wear on large fans, extending service intervals. For compressors, the integrated overload protection and trip classes ensure reliable operation under varying load conditions. The controller’s ability to handle 108 A line-connected or 187 A delta-connected motors provides flexibility for retrofit projects. In all these scenarios, the SMC Flex contributes to reduced downtime and lower maintenance costs, aligning with the value-driven expectations of industrial engineers.

Figure 2: Technical layout and connection details for the Allen-Bradley 150-F108NBRB industrial automation component.

Installation & Setup Guidelines

Proper installation is critical to the performance and longevity of the soft starter. Mount the controller vertically on a flat, vibration-resistant surface, allowing adequate clearance for airflow—especially important since the open-type enclosure relies on panel ventilation. Connect power terminals using M10 x 1.5 hardware per pole, and torque to manufacturer specifications. Control wiring should use clamping yoke connections with M3 screws; ensure control voltage matches the 24 V AC/DC requirement. The input OFF-state current is less than 10 mA AC or 3 mA DC, compatible with most PLC outputs. For delta-connected motors, verify that the motor’s six leads are correctly configured and that overload current settings (47 A for delta) are adjusted accordingly. Always follow local electrical codes and verify short-circuit protection device ratings against the 70 kA maximum fault current.

Compatibility & Integration

The 150-F108NBRB integrates seamlessly with Allen-Bradley control systems and third-party PLCs via its hardwired I/O. The four programmable auxiliary contacts (Aux #1–#4) can be configured as NO or NC, providing status signals for run, fault, or alarm conditions. For network connectivity, the controller does not include an embedded communication protocol such as PROFINET or EtherNet/IP. Integration Note: Wiring into such fieldbus networks may require an external gateway or connection module. Confirm cable and gateway compatibility with Mronexus before commissioning. The controller also supports PTC thermistor inputs (up to 6 sensors) for direct motor winding protection, and a tachometer input (0–5 V DC) for speed feedback in advanced control schemes.

Maintenance & Reliability

Designed for industrial environments, the SMC Flex controller requires minimal maintenance but benefits from regular inspection. Check heatsink fins for dust accumulation every 6–12 months, especially in high-particulate environments; the optional heatsink fan (20 VA) can be tested for operation during scheduled downtime. Verify terminal tightness annually to prevent loose connections that can cause arcing. The RC snubber network and metal oxide varistors (if installed) should be inspected for signs of degradation after severe voltage events. Operating within the -5 to 50 °C range and maintaining humidity below 95% non-condensing will maximize service life. The internal bypass reduces thermal stress during continuous running, contributing to energy savings and extended component life—a key cost-benefit for high-cycle applications.

Product Support & Availability

Mronexus stocks the Allen-Bradley 150-F108NBRB and is ready to ship worldwide. As your one-stop sourcing base for PLC, HMI, servo, sensor, and circuit breaker needs, we ensure fast delivery and genuine parts at competitive prices. Contact Mronexus for genuine industrial automation parts and technical support.

Frequently Asked Questions

Q: What is the operating temperature range for the 150-F108NBRB?

A: The open-type enclosure is rated for -5 to 50 °C (23 to 122 °F). Ensure adequate panel ventilation and respect altitude derating above 2000 m.

Q: What control voltage does the 150-F108NBRB require?

A: The control circuit accepts 24 V AC at 50/60 Hz or 24 V DC, with an input ON-state voltage minimum of 85 V AC or 19.2 V DC. Use a regulated 24 V DC power supply such as the 1606-XLP50E for reliable operation.

Q: Can the 150-F108NBRB be integrated into a PROFINET or EtherNet/IP network?

A: The standard controller does not include a native fieldbus port. For network integration, an external communication gateway or module is required. Confirm compatible gateways and cabling with Mronexus before ordering.

Q: What overload protection does the 150-F108NBRB provide?

A: It features integrated electronic motor overload protection with trip classes 10, 15, 20, and 30, and a trip current rating of 117% of motor FLC. PTC thermistor inputs are also supported for enhanced motor protection.

Unmatched Customer Service

  • After Hours Shipping
  • Real Time Order Tracking
  • Flexible Delivery Options
  • Intact Technical Supports

Need a quote or technical support?

Send us your part numbers and we will get back within 24 hours.

Contact Us