AP-34KP | Keyence Compound Pressure Sensor 12-24 VDC
PLC
- Brand: Keyence
- Part Number:
AP-34KP - Availability: Ask for quote
Keyence AP-34KP compound pressure sensor offers 12-24 VDC operation, PNP output, and a clear 2-color LED display for reliable pressure monitoring in industrial applications.
Product Details
Solving Pressure Monitoring Challenges with the Keyence AP-34KP
Engineers often face the challenge of monitoring both positive and negative pressure in pneumatic systems without installing multiple sensors. The Keyence AP-34KP compound pressure sensor addresses this by covering a rated range of 29.9 to -29.9 inchHg, making it ideal for vacuum and positive pressure applications. As part of the AP-30 series, this digital pressure sensor combines a 3½-digit, 2-color LED display with PNP open collector outputs, ensuring clear readings and reliable switching. Whether you’re upgrading an existing system or designing a new one, the AP-34KP provides a genuine, value-for-money solution for precise pressure control.

Key Features and Technical Specifications
- Operating temperature: 0 to +50 °C (no freezing), suitable for standard industrial environments.
- Input voltage: 12 to 24 VDC ±10%, with current consumption of 50 mA max at 24 V and 90 mA max at 12 V.
- Power supply: 12-24 VDC, compatible with common control panel supplies.
- Communication protocol: None built-in; no communication ports or expansion, ensuring simple standalone operation.
- Output type: PNP open collector, 2-output (N.O./N.C. selectable), rated 100 mA max at 30 V max, residual voltage 1 V max.
- Analog output: 1 to 5 V (load impedance 47 kΩ minimum) for continuous pressure monitoring.
- Display: 3½-digit, 2-color, 7-segment LED with 11 mm character height for easy reading.
- Pressure range: Rated 29.9 to -29.9 inchHg; detectable -15 to +110% of F.S.
- Fluid type: Air or non-corrosive gases; gauge pressure measurement.
- Pressure resistance: 72.5 PSI proof pressure.
- Vibration resistance: 10 to 55 Hz, double amplitude 1.5 mm, 2 hours in each X, Y, Z direction.
- Materials: Polyamide front housing, PET front panel sheet, polysulfone rear housing, die-cast zinc pressure port, oil-proof cabtyre cable.
- Weight: Approx. 120 g.
The 2-color LED display is a standout feature, allowing operators to quickly identify normal vs. alarm conditions. With a display resolution of 0.1 inchHg (or 0.2 kPa, 2 mmHg, 0.002 bar), even small pressure changes are visible. The selectable response time (2.5/5/100/500 ms) helps prevent chattering in fluctuating systems.
Applications and Use Cases
The AP-34KP excels in vacuum clamping systems, where maintaining negative pressure is critical for workpiece holding. Its compound range allows the same sensor to monitor both vacuum and positive pressure during clamping and release phases. In leak testing equipment, the fast response time and analog output enable precise detection of pressure decay. For pneumatic conveyors, the sensor ensures air pressure stays within optimal limits, preventing blockages. Additionally, in packaging machinery, it verifies vacuum levels for pick-and-place operations, reducing product loss. These applications benefit from the sensor’s reliable performance and the genuine Keyence quality that Mronexus supplies at competitive prices.

Installation and Setup
Mount the AP-34KP using the provided mounting threads on the pressure port. Connect the 12-24 VDC power supply, ensuring polarity is correct. The PNP output can be wired to PLC inputs or relays; select N.O. or N.C. via the front panel buttons. For analog output, use shielded cable to minimize noise, and ensure load impedance is at least 47 kΩ. The oil-proof cable is suitable for environments with oil mist. Avoid installing in locations with excessive vibration or temperature fluctuations beyond the specified range.
Maintenance and Reliability
Regular inspection of the pressure port for debris and checking cable integrity every 6 months is recommended. The sensor’s polyamide and polysulfone housing resist many industrial chemicals, but avoid exposure to corrosive gases. Operating within 0-50 °C and 35-85% RH ensures long-term reliability. The 2-color display aids in quick diagnostics, reducing downtime. With proper care, the AP-34KP provides dependable service, supporting cost-effective operations.
Compatibility and Integration
The AP-34KP integrates easily with PLCs and control systems via its PNP outputs and analog voltage. No communication protocol is built-in, so no network configuration is needed. For systems requiring digital communication, consider adding a separate gateway. The sensor is compatible with standard pneumatic fittings. When integrating into existing panels, verify that the 12-24 VDC supply can provide the required current.
Frequently Asked Questions
Q: What is the operating temperature range of the AP-34KP?
A: The sensor operates from 0 to +50 °C (no freezing). Ensure the environment stays within this range for reliable performance.
Q: Can the AP-34KP communicate over a network?
A: No, it has no built-in communication ports or protocols. It provides PNP outputs and analog voltage for integration with PLCs or controllers.
Q: What is the power supply requirement?
A: It requires 12 to 24 VDC ±10%, with current consumption of 50 mA max at 24 V or 90 mA max at 12 V.
Q: Is the AP-34KP suitable for vacuum applications?
A: Yes, it measures compound pressure from 29.9 to -29.9 inchHg, making it ideal for vacuum and positive pressure systems.
Product Support and Availability
The Keyence AP-34KP is in stock and ready to ship from Mronexus. As your one-stop sourcing base for industrial automation parts, we offer genuine products at competitive prices with fast delivery. Contact Mronexus for genuine industrial automation parts and experience reliable service.
Unmatched Customer Service
- After Hours Shipping
- Real Time Order Tracking
- Flexible Delivery Options
- Intact Technical Supports