CIMR-V7AM42P2 | Yaskawa Varispeed 3HP 460V AC Drive
VFD
- Brand: Yaskawa
- Part Number:
CIMR-V7AM42P2 - Availability: Ask for quote
The Yaskawa CIMR-V7AM42P2 Varispeed AC drive delivers reliable 3HP motor control at 460V. Engineered for durability and easy maintenance, it’s ideal for demanding industrial applications.
Product Details
Product Introduction
In industrial automation, the reliability of a variable frequency drive (VFD) can make or break your production line. The Yaskawa CIMR-V7AM42P2, part of the renowned Varispeed series, is a 3HP AC drive designed to provide precise motor control while withstanding the rigors of continuous operation. With a 460V three-phase input and 8.1A current rating, this drive is a workhorse for applications requiring dependable performance. As a maintenance engineer, you’ll appreciate its robust construction and straightforward serviceability, ensuring minimal downtime and maximum productivity.

Key Features & Technical Specifications
- Power Rating: 2.2 kW (3 HP) – handles medium-duty motor loads with ease.
- Input Voltage: 460 V AC, 3-phase – compatible with standard industrial power systems.
- Current Rating: 8.1 A – delivers ample current for motor starting and running.
- Frequency Range: 50/60 Hz – supports both standard and high-speed operations.
- Operating Temperature: Refer to official datasheet for specific temperature range.
- Communication Protocol: Refer to official datasheet for supported networks.
- Operating Humidity: Up to 80% (non-condensing) – suitable for most plant environments.
- Maximum Altitude: 1000 m above sea level – without derating.
- Weight: 3.69 lbs (1.67 kg) – compact and easy to install.
The CIMR-V7AM42P2 stands out for its robust design and ease of maintenance. The 8.1A current rating provides a 20% overload capability for short durations, ensuring reliable operation even under transient loads. This makes it an excellent choice for applications where motor starting torque is critical.
Failure Mode Analysis: Preventing Downtime
From a maintenance engineer’s perspective, understanding common failure modes is key to maximizing uptime. The CIMR-V7AM42P2 is engineered to mitigate typical VFD issues:
- Overheating: Ensure proper ventilation and clean heatsinks regularly. The drive’s operating humidity limit of 80% non-condensing means it can handle humid environments, but condensation must be avoided.
- Voltage Spikes: Use appropriate line reactors and surge suppressors to protect the drive from transient overvoltages, especially in facilities with heavy inductive loads.
- Bearing Wear: Cooling fans are a common wear point. Inspect fan operation every 6 months and replace if noisy or slow.
- Capacitor Degradation: Electrolytic capacitors age over time. Schedule periodic checks of DC bus capacitors after 5 years of service.
By addressing these factors proactively, you can extend the drive’s service life and avoid unplanned stoppages.

Installation & Setup
Installing the CIMR-V7AM42P2 is straightforward, thanks to its compact footprint and clear terminal layout. Mount the drive vertically on a sturdy surface, allowing at least 100 mm clearance above and below for airflow. Connect the three-phase input to terminals R/L1, S/L2, T/L3, and the motor to U/T1, V/T2, W/T3. Use shielded cables for motor wiring to minimize electromagnetic interference. Ground the drive properly to a low-impedance earth ground. Before power-up, verify all connections and set the motor parameters (voltage, current, frequency) via the digital operator or configuration software. For detailed wiring diagrams and parameter lists, refer to the official Yaskawa documentation.
Maintenance & Reliability
Regular maintenance is the cornerstone of reliable VFD operation. The CIMR-V7AM42P2 is designed for easy serviceability, with accessible components and clear diagnostic indicators. Establish a preventive maintenance schedule:
- Monthly: Inspect for dust accumulation, loose connections, and unusual noises. Clean or replace air filters if used in the enclosure.
- Every 6 months: Check cooling fan operation and clean heatsink fins. Verify terminal tightness.
- Annually: Measure insulation resistance of motor cables and check DC bus capacitor capacitance.
By following these steps, you can maximize the drive’s lifespan and maintain peak efficiency, contributing to lower total cost of ownership.
Compatibility & Integration
The CIMR-V7AM42P2 integrates seamlessly with Yaskawa’s Varispeed series and is compatible with a wide range of AC motors. It supports standard industrial communication protocols (refer to datasheet for specifics). Integration Note: When connecting to fieldbus networks such as PROFINET or EtherNet/IP, an external gateway or communication module may be required. Confirm cable and gateway compatibility with your supplier before installation.
FAQ
Q: What is the operating temperature range for the CIMR-V7AM42P2?
A: The operating temperature range is not specified in the provided data. Please refer to the official Yaskawa datasheet or contact Mronexus for detailed specifications.
Q: Can this drive be used with single-phase power?
A: No, the CIMR-V7AM42P2 requires a three-phase 460V AC input. It is not designed for single-phase operation.
Q: What communication protocols are supported?
A: The communication protocol is not specified in the provided data. Refer to the official Yaskawa documentation for supported networks and options.
Q: How often should I replace the cooling fan?
A: Cooling fan life depends on operating conditions. Inspect every 6 months and replace if any abnormal noise or reduced airflow is detected. Typical replacement interval is 2-3 years in clean environments.
Product Support & Availability
The Yaskawa CIMR-V7AM42P2 is in stock and ready to ship from Mronexus. As your one-stop sourcing base for genuine industrial automation parts, we offer fast delivery and competitive prices. Contact Mronexus for genuine industrial automation parts and experience reliable, value-for-money service.
Unmatched Customer Service
- After Hours Shipping
- Real Time Order Tracking
- Flexible Delivery Options
- Intact Technical Supports