IC755CSS06RDA | GE QuickPanel+ 6″ HMI, 24VDC, Ethernet
PLC
- Brand: GE
- Part Number:
IC755CSS06RDA - Availability: Ask for quote
The IC755CSS06RDA is a GE QuickPanel+ 6-inch HMI operator terminal with 24VDC input, Ethernet and RS232 communication, designed for reliable industrial visualization.
Product Details
Product Introduction
In industrial automation, the human-machine interface (HMI) is the operator’s primary window into process status and control. When an HMI fails, visibility is lost, and production risks increase. The IC755CSS06RDA from GE (now under Emerson Automation) is a QuickPanel+ operator terminal built to deliver dependable visualization in demanding environments. With a 6-inch TFT display, 24 VDC input, and both Ethernet and RS232 ports, this HMI balances performance with ease of service—making it a practical choice for maintenance engineers who value uptime and straightforward replacement.

Key Features & Technical Specs
- Display: 6-inch TFT LCD, 320 x 240 pixels, LED backlight, 310 cd/m² brightness.
- Touchscreen: Analog resistive touch cells for direct operator input.
- Processor: Intel Freescale i.MX535 1 GHz ARM Cortex A8.
- Memory: 512 MB DDR2 SDRAM, 256 MB SLC NAND Flash, 512 KB SRAM (battery backup).
- Operating Temperature: 0 to 55 °C (32 to 131 °F).
- Input Voltage: 24 VDC; power consumption 15 W max.
- Communication: One 10/100BaseT Ethernet (RJ-45) and one RS232 UART (5-pin).
- USB Ports: Two USB 2.0 Type-A host, one USB 2.0 Mini Type-B device.
- Storage: SD/SDHC card slot for data logging and project transfer.
- Operating System: Windows Compact Embedded 7.
- Mounting: Panel mount or VESA 75.
- Weight: 0.62 kg (1.38 lbs).
The combination of a 1 GHz processor and 512 MB RAM ensures responsive screen updates and quick project downloads, reducing commissioning time. The 24 VDC input is standard in industrial cabinets, simplifying integration with existing power supplies.
Applications & Use Cases
The IC755CSS06RDA excels in applications where reliable operator interaction is critical. On a packaging line, it provides real-time status of sensors and actuators, allowing operators to quickly adjust parameters. In water treatment plants, the HMI displays process variables and alarms, helping staff respond to deviations before they escalate. For maintenance engineers, the Ethernet port enables remote diagnostics, reducing the need for physical presence at the machine. The RS232 port can connect to legacy controllers or barcode scanners, extending the HMI’s utility. In all these scenarios, the robust design and wide operating temperature range ensure consistent performance.

Installation & Setup
Mounting the IC755CSS06RDA is straightforward with panel mount or VESA 75 options. Ensure the 24 VDC power supply is stable and within specifications; use a dedicated circuit to avoid voltage fluctuations. For communication, connect the Ethernet cable to the RJ-45 port (max 100 m per segment) and the RS232 cable to the 5-pin connector (max 15 m). The USB ports allow connection of a keyboard, mouse, or USB drive for project updates. The SD card slot simplifies project transfer and data logging. During commissioning, verify that the operating temperature remains within 0–55 °C; avoid mounting near heat sources.
Maintenance & Reliability
From a maintenance perspective, the IC755CSS06RDA is designed for ease of service. The resistive touchscreen is durable but should be cleaned regularly with a soft, damp cloth to prevent dust buildup that can affect responsiveness. Inspect the SD card slot and USB ports for contamination; use covers when not in use. The SRAM battery backup (512 KB) should be checked periodically—if the battery fails, SRAM data may be lost during power cycles. The LED backlight has a long life, but brightness degradation over time is normal; schedule replacement if visibility becomes poor. Operating within the specified temperature range and humidity (up to 85%) maximizes reliability. By following these practices, engineers can extend the HMI’s service life and minimize unplanned downtime.
Compatibility & Integration
The IC755CSS06RDA integrates seamlessly with GE Fanuc and Emerson PLCs via Ethernet/IP and RS232. The Windows Compact Embedded 7 OS supports standard networking protocols such as FTP and SNTP, enabling easy project updates and time synchronization. For integration with other fieldbus networks (e.g., PROFINET, EtherNet/IP), an external gateway may be required; confirm cable and gateway compatibility with the supplier. The two USB host ports allow connection of peripherals like barcode scanners or USB drives, while the Mini Type-B device port facilitates direct PC connection for programming.
Product Support & Availability
Mronexus stocks the IC755CSS06RDA and other genuine industrial automation parts, offering fast delivery from stock. As your one-stop sourcing base for PLC, HMI, servo, sensor, and circuit breaker needs, we ensure reliable supply and competitive pricing. Contact Mronexus for genuine industrial automation parts and experience value-for-money service.
FAQ
Q: What is the operating temperature range of the IC755CSS06RDA?
A: The HMI operates reliably from 0 to 55 °C (32 to 131 °F), suitable for most industrial environments.
Q: Can the IC755CSS06RDA communicate over Ethernet/IP?
A: Yes, it has a 10/100BaseT Ethernet port that supports Ethernet/IP for communication with PLCs and other devices.
Q: What is the input voltage and power consumption?
A: It requires 24 VDC input and consumes a maximum of 15 W.
Q: How do I transfer projects to the HMI?
A: Projects can be transferred via the SD card slot, USB ports, or Ethernet using FTP.
Q: Is the touchscreen resistive or capacitive?
A: The IC755CSS06RDA features an analog resistive touchscreen, which allows operation with gloves and is highly durable in industrial settings.
Unmatched Customer Service
- After Hours Shipping
- Real Time Order Tracking
- Flexible Delivery Options
- Intact Technical Supports