Skip to content
sales@mronexus.com +86 180 3000 5825 Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China Reply within 24 hours Worldwide shipping

IC670GBI002 | GE Field Control Bus Interface Unit 24VDC

PLC

  • Brand: GE
  • Part Number: IC670GBI002
  • Availability: Ask for quote

The GE IC670GBI002 is a Field Control Bus Interface Unit that connects up to eight I/O modules to a host PLC via Genius Bus. It supports hot insertion and removal, operates from 0 to 55°C, and offers 183,000 hours MTBF for reliable industrial service.

Product Details

IC670GBI002: The Reliable Backbone of GE Field Control I/O

For maintenance engineers, the bus interface unit is the single point of failure that can bring an entire I/O segment down. The GE Fanuc IC670GBI002 is engineered to eliminate that risk. As the header module of a Field Control system, it manages data exchange between up to eight I/O modules and a host PLC or computer over Genius Bus. With a mean time before failure (MTBF) exceeding 183,000 hours, it delivers the reliability that keeps production lines running.

This module is part of the GE Fanuc Field Control series and is designed for hot insertion and removal, allowing you to replace it without disconnecting field wiring. That means less downtime and faster service—critical for maintenance teams. At Mronexus, we supply genuine industrial automation parts like the IC670GBI002 at competitive prices, with worldwide shipping from stock.

Figure 1: Front view of the GE IC670GBI002 industrial automation component showing its physical design and enclosure.

Key Technical Specifications

  • Input voltage: 18–30 VDC (nominal 24 VDC); also accepts 90–135 VAC or 105–150 VDC via terminal block.
  • Power consumption: 16.8 W at full load; 48 VA at 115 VAC; 24 W at 125 VDC.
  • Operating temperature: 0°C to 55°C (32°F to 131°F); storage -40°C to 85°C.
  • Communication protocol: Genius Bus; exchanges up to 128 bytes input and 128 bytes output per scan.
  • I/O capacity: Supports up to eight Field Control I/O modules.
  • Holdup time: 10 ms (20 ms maximum) for ride-through of short power interruptions.
  • Inrush current: 15–50 A peak for 3 ms maximum.
  • Power supply output: 6.5 VDC ±5% at 1.4 A to backplane modules.
  • MTBF: 183,000 hours (module); 600,000 hours (terminal block).
  • Humidity: 5–95% non-condensing.

The 10 ms holdup time is a standout feature: it allows the BUI to ride through brief power dips without dropping communication, preventing unnecessary fault trips and production interruptions.

Installation and Setup

The IC670GBI002 mounts on a standard DIN rail (at least 108 mm wide) that is connected to a reliable grounding system. Use a DIN rail material with good conductivity and resistance to oxidation. Wiring for power and Genius Bus communication terminates on the compatible terminal block (TBUI). The module accepts wire gauge AWG #14. Ensure the terminal block is securely fastened and that communication cables are routed away from high-noise sources. The unit is designed for non-hazardous locations; if used in hazardous areas, additional protection is required.

Figure 2: Technical layout and connection details for the GE IC670GBI002 industrial automation component.

Maintenance and Reliability

From a maintenance perspective, the IC670GBI002 is built for serviceability. Because it supports hot insertion and removal, you can replace a faulty unit without powering down the I/O segment—provided the appropriate Field I/O module versions are installed. The module performs diagnostic tests on itself and connected I/O modules, relaying results to a host device or handheld monitor (version 4.6 or later). Use these diagnostics for predictive maintenance: schedule inspections at least annually, checking for dust buildup, secure terminal connections, and proper grounding. The wide operating temperature range (0–55°C) and robust noise immunity make it suitable for typical industrial cabinets, but ensure ambient stays within limits to achieve the full 183,000-hour MTBF.

Compatibility and Integration

The IC670GBI002 is compatible with GE Fanuc Series 90-30, 90-70, Series Six, and Series Five PLCs, as well as Genius hand-held monitors. It supports hot standby CPU redundancy for critical applications. When integrating into a Genius Bus network, note that wiring may require an external gateway or connection module; confirm cable and gateway requirements with your supplier. The module also supports Genius datagram communications for advanced diagnostics.

Why Choose the IC670GBI002 from Mronexus

As a discontinued/obsolete part, the IC670GBI002 can be difficult to source. Mronexus specializes in genuine industrial automation parts at below-market prices, offering one-stop sourcing for PLC, HMI, servo, sensors, and circuit breakers. We ship worldwide with fast delivery from stock, so you can get the parts you need without long lead times. Contact Mronexus for genuine industrial automation parts and keep your Field Control system running reliably.

Unmatched Customer Service

  • After Hours Shipping
  • Real Time Order Tracking
  • Flexible Delivery Options
  • Intact Technical Supports

Latest News

Insights, product guides and industry updates from our team.

Need a quote or technical support?

Send us your part numbers and we will get back within 24 hours.

Contact Us