Genuine Vibro Meter 111-402-000-013 Ex i proximity measuring system: eddy-current, API 670, -40 to +180 °C, 10 m total length. Reliable shaft vibration monitoring.
Product Details
Evaluating the Vibro Meter 111-402-000-013 for Reliable Shaft Vibration Monitoring
When a proximity measuring system fails, the consequences ripple through your entire machinery protection chain—false trips, missed alarms, or worse, undetected shaft instability. The Vibro Meter 111-402-000-013 (Meggitt) is engineered to eliminate those failure modes before they start. This Ex i rated eddy-current system delivers non-contact measurement for API 670 applications, with a temperature-compensated design that maintains accuracy from −40 to +180 °C. For engineers sourcing genuine industrial automation parts at competitive prices, this 10 m system offers a reliable, value-for-money solution.

Key Technical Specifications
- Operating temperature: −40 to +180 °C with drift <5%; short-term survival to +220 °C.
- Input voltage: High-frequency power source from IQS900 signal conditioner.
- Power supply: Requires external signal conditioner (IQS900) for transducer excitation.
- Communication protocol: Analog voltage or current output (short-circuit protected).
- Measurement range: 2 or 4 mm (system dependent).
- Frequency response: DC to 20 kHz (−3 dB).
- Environmental rating: Ex i (Explosive atmosphere), IP68 transducer head.
- Body thread: M10 × 1, 30 mm body length.
- Integral cable: 1.0 m ±100 mm, FEP-covered 70 Ω coaxial.
- Total system length: 10 m.
The Ex i certification and wide temperature range are standout features—they allow direct installation in hazardous areas without additional barriers, reducing wiring complexity and cost.
Failure Mode Analysis: Where Proximity Systems Fail and How This Model Mitigates Risk
Eddy-current transducers typically fail due to thermal stress, mechanical damage, or signal degradation. The 111-402-000-013 addresses each:
- Thermal drift: Temperature-compensated design keeps drift under 5% across the full operating range, preventing false alarms during process upsets.
- Cable damage: FEP-covered coaxial cable resists chemicals and moisture; optional stainless steel hose (not included, G000) adds mechanical protection where needed.
- Connector issues: Self-locking miniature coaxial connectors require hand-tightening until locked—avoiding intermittent signals from vibration loosening.
- Environmental ingress: IP68 transducer head survives washdowns and temporary submersion; Ex i certification ensures safe operation in explosive atmospheres.
By selecting the correct cable length (1.0 m integral, 10 m total) and thread (M10 × 1), you eliminate installation mismatches that cause premature failure.

Applications and Use Cases
This system is ideal for shaft relative vibration and gap/position measurement chains on critical machinery—steam turbines, compressors, and large motors. It integrates seamlessly with VM600Mk2, VM600, and VibroSmart® monitoring systems for API 670 compliance. In a typical failure-mode scenario, a refinery uses the 111-402-000-013 to monitor compressor shaft vibration; the Ex i rating allows direct mounting in a Zone 1 area, while the 10 m system length reaches the junction box without extension cables. For condition monitoring, the DC-to-20 kHz response captures both low-frequency runout and high-frequency rubs.
Installation and Setup
Mount the transducer using the M10 × 1 thread, ensuring the 30 mm body length clears the housing. The unthreaded length is 0 mm min, so the tip sits flush with the target. Connect the integral 1.0 m cable to the extension cable (total 10 m) using the self-locking connectors—hand-tighten until locked. Power the transducer from an IQS900 signal conditioner; verify output voltage or current with a multimeter. For Ex i installations, confirm the associated apparatus (barrier or isolator) is correctly rated. Always follow API 670 recommendations for target size and gap voltage.
Compatibility and Integration
The 111-402-000-013 is compatible with Vibro-Meter VM600Mk2, VM600, and VibroSmart® systems. The analog output (voltage or current) interfaces with standard PLC analog inputs; however, for fieldbus networks (PROFINET, EtherNet/IP), an external gateway or connection module may be required. Confirm cable and gateway compatibility with your supplier. The system’s 70 Ω coaxial cable and self-locking connectors are designed for low-noise signal transmission over 10 m.
Maintenance and Reliability
Inspect the transducer tip and cable quarterly for mechanical damage or chemical attack. Check connector tightness annually—vibration can loosen even self-locking types. In high-temperature zones, monitor for drift beyond 5%; if exceeded, replace the transducer. The FEP sheath resists most chemicals, but avoid sharp bends that stress the cable. With proper care, the system delivers long service life, reducing downtime and replacement costs. Keep spare transducers on hand—Mronexus stocks genuine parts for fast delivery.
Frequently Asked Questions
Q: What is the operating temperature range of the 111-402-000-013?
A: The transducer operates from −40 to +180 °C with drift <5%. Short-term survival up to +220 °C is possible but with increased drift. The cable and connector are rated −40 to +200 °C.
Q: Can this system be used in hazardous areas?
A: Yes, the Ex i (Explosive atmosphere) certification allows use in Zone 1 and Zone 2 hazardous areas when connected to a suitable intrinsically safe barrier or isolator. Confirm the entire loop complies with local regulations.
Q: What signal conditioner is required?
A: The transducer requires a high-frequency power source from an IQS900 signal conditioner. This provides excitation and demodulates the eddy-current signal to a voltage or current output.
Q: What is the total system length and cable type?
A: The system includes a 1.0 m integral cable and extension cable for a total length of 10 m. The cable is FEP-covered 70 Ω coaxial, Ø3.6 mm, with self-locking miniature coaxial connectors.
Q: Is this product API 670 compliant?
A: Yes, the 111-402-000-013 conforms to API 670 recommendations for machinery protection systems. It is ideal for use with VM600Mk2, VM600, and VibroSmart® monitoring systems.