140DAO84000 | Schneider Electric Modicon Quantum 16-Point AC Triac Output Module
PLC
- Brand: Schneider Electric
- Part Number:
140DAO84000 - Availability: Ask for quote
Schneider Electric 140DAO84000 is a 16-point AC Triac discrete output module for Modicon Quantum PLCs, featuring individual channel isolation and blown fuse diagnostics.
Product Details
Problem-Solution: Overcoming AC Load Switching Challenges in Legacy Quantum Systems
Engineers maintaining Modicon Quantum control systems often face a common pain point: sourcing reliable AC output modules that can handle diverse inductive and resistive loads without frequent failures. The Schneider Electric 140DAO84000 addresses this directly. As a 16-point AC Triac discrete output module, it provides a robust, non-relay solution for switching 20–253 V AC field devices. While the module is now discontinued (End of Sale, last verified 2026-09), genuine units remain available through specialist suppliers like Mronexus, ensuring your legacy Quantum platform stays operational.

Key Features & Technical Specifications
The 140DAO84000 is engineered for high-density, reliable AC output control. Each of the 16 channels is individually isolated, reducing cross-talk and simplifying fault isolation. Key parameters include:
- Channels: 16 points, individually isolated (16-channel isolation).
- Signal Type: AC output via Triac (bidirectional thyristor), non-relay design for long life.
- Voltage Range: 20 to 253 V AC, supporting a wide variety of AC loads.
- Output Current: 3 A rms per output at 200–230 V; 4 A rms per output at 24–115 V; 16 A rms per module; 4 A rms per 4-point group continuous.
- Response Time: 0.75–4.9 ms off-on, 7.3–12.3 ms on-off.
- Diagnostics: Blown fuse and loss of field power indicated via LEDs.
- Power Supply: 5 V DC backplane; bus current 350 mA; power consumption 1.85 W + (1.1 V × total load current).
- Operating Temperature: Refer to official datasheet for operating temperature.
- Protection Rating: IP20.
- Dimensions (H×W×D): 250 × 40.34 × 103.85 mm; weight 0.485 kg.
- Slots Required: 1.
The Triac output design eliminates mechanical wear, offering a distinct advantage over relay-based modules in high-cycle applications. The individual channel isolation is particularly valuable in panels where mixed signal types coexist, preventing fault propagation.
Installation & Setup Best Practices
Installing the 140DAO84000 into a Modicon Quantum rack is straightforward, but attention to wiring and grounding ensures reliable operation. Use the single slot required and secure the module firmly. Because the outputs are AC Triac types, ensure that load wiring is separated from low-level signal cables to minimize induced noise. The backplane supply of 5 V DC is derived from the rack power supply; verify that the total bus current (350 mA) and power consumption are within the rack’s capacity. For field wiring, observe the 4 A rms per 4-point group limit and use appropriate fusing. The built-in blown fuse diagnostics will illuminate an LED if a fuse opens, simplifying troubleshooting.

Compatibility & Integration with Quantum Systems
The 140DAO84000 is designed exclusively for the Modicon Quantum platform, communicating via the backplane bus. It does not include a fieldbus interface; integration into networks such as Modbus Plus, PROFINET, or EtherNet/IP requires the appropriate Quantum communication modules or an external gateway. When planning a replacement or spare-parts strategy, confirm that your rack firmware and CPU support the module. Mronexus offers genuine industrial automation parts at below-market prices, including one-stop sourcing for PLC, HMI, servo, sensor, and circuit breakers, so you can consolidate your spares procurement.
Reliability & Maintenance for Discontinued Modules
Although the 140DAO84000 is discontinued, its solid-state Triac design minimizes wear and extends service life. Regular maintenance should focus on environmental factors: ensure the enclosure maintains IP20 protection and that ambient temperature remains within the original specifications (refer to datasheet). Inspect terminal connections for tightness and check diagnostic LEDs periodically. Because the module is no longer in production, stocking genuine spare units is a prudent risk-mitigation step. Mronexus maintains stock of genuine parts at competitive prices, enabling fast delivery and reducing downtime risk.
Frequently Asked Questions
Q: What is the operating temperature range of the 140DAO84000?
A: The operating temperature is not available in the provided data. Refer to the official Schneider Electric datasheet or contact Mronexus for assistance.
Q: Can the 140DAO84000 drive inductive AC loads?
A: Yes, the Triac output is suitable for AC loads within the specified current and voltage range. However, for highly inductive loads, ensure proper snubber circuits or consult the datasheet for derating.
Q: What communication protocol does this module use?
A: The 140DAO84000 communicates via the Modicon Quantum backplane; it does not have a direct fieldbus port. Network integration requires a separate communication module or gateway.
Q: Is the 140DAO84000 still available?
A: The module is discontinued (End of Sale). Mronexus supplies genuine units from stock; contact us for current availability and pricing.
Product Support & Availability
Mronexus is your one-stop sourcing base for genuine industrial automation parts, including the 140DAO84000. We maintain stock of legacy Schneider Electric modules and offer worldwide shipping with fast delivery. Contact Mronexus for genuine industrial automation parts and to discuss your Quantum system requirements.
Unmatched Customer Service
- After Hours Shipping
- Real Time Order Tracking
- Flexible Delivery Options
- Intact Technical Supports