1746-OW8/A | Allen-Bradley SLC 500 Relay Output Module
PLC
- Brand: Allen-Bradley
- Part Number:
1746-OW8/A - Availability: Ask for quote
The Allen-Bradley 1746-OW8/A is an 8-channel relay output module for SLC 500 PLCs, switching 5-265 VAC or 5-125 VDC loads with 1500 VAC isolation. Ideal for motor starters, solenoids, and pilot devices.
Product Details
Part Number: 1746-OW8/A
Manufacturer: Allen-Bradley (Rockwell Automation)
Series: SLC 500 / Bulletin 1746
Base Catalog: 1746-OW8

Series Suffix: A
Product Type: Relay Output Module
Series / Family Common Specifications:
- Modular systems mount modules in a 1746 chassis (1746-A4/-A7/-A10/-A13) with 4/7/10/13 slots; all chassis are panel-mount.
- The 1746 chassis backplane supplies 5.1V DC @ 10A and 24V DC @ 2.88A power bus to all modules.
- Family operating temperature 0 to 60 C; storage -40 to 85 C; 5-95% RH non-condensing.
- I/O modules draw 5V DC logic via backplane; field-side load power needs an external supply.
- Removable terminal blocks for field wiring; Bulletin 1492 pre-wired interface available.
- Not hot-swappable: do not install/remove/wire with power applied. Slot 0 reserved for processor or 1747-ASB adapter.
Model-Specific Specifications:

- 8 normally-open relay outputs (2 groups of 4)
- operating voltage 5-265 VAC or 5-125 VDC
- 1.5 A per output at 120 VAC, 1.2 A per output at 24 VDC
- 8 A continuous per common, 16 A continuous per module
- backplane current 85 mA @ 5V DC and 90 mA @ 24V DC
- signal delay 10 ms ON / 10 ms OFF
- relay isolation (1500 VAC contacts to backplane)
- chassis mount (1746 I/O chassis)
- open-style
- operating temp 0 to 60 C.
Description: The Allen-Bradley 1746-OW8 is an eight-channel electromechanical relay output module for the SLC 500 programmable controller platform, providing isolated normally-open contacts that switch both AC and DC loads. Its eight outputs are divided into two commons of four points each, supporting mixed-voltage control environments such as motor starters, solenoids, pilot devices, alarms, and interposing relays. The module mounts in any SLC 500 chassis or remote I/O rack and is widely used in factory automation, packaging equipment, material handling, and process control panels requiring relay-based output control.
Lifecycle:
Status: Discontinued
Discontinuation Date: 2022-12-31
Replacement: Engineering Replacement
Note: SLC 500 (Bulletin 1746) platform; Rockwell has discontinued many 1746 I/O modules and recommends migration to Compact 5000 I/O with the Logix platform.
Confidence: Official (Rockwell per-model product page)
Last verified: 2026-09
Unmatched Customer Service
- After Hours Shipping
- Real Time Order Tracking
- Flexible Delivery Options
- Intact Technical Supports