2198-C4030-ERS | Allen-Bradley Kinetix 5300 6.25kW Servo Drive
PLC
- Brand: Allen-Bradley
- Part Number:
2198-C4030-ERS - Availability: Ask for quote
Allen-Bradley 2198-C4030-ERS Kinetix 5300 single-axis servo drive: 6.25kW, 380-480V AC, EtherNet/IP, hardwired STO. Genuine parts, fast delivery from stock.
Product Details
Product Introduction
When a packaging line loses its main axis drive, every minute of downtime erodes throughput and margin. The Allen-Bradley 2198-C4030-ERS from the Kinetix 5300 series is a single-axis servo drive engineered to keep integrated motion systems running on EtherNet/IP. As a Frame 2 drive rated 6.25 kW at 400V AC three-phase, it delivers 11.7 A continuous output current with 34.1 A peak for up to 1.0 s — enough headroom for demanding acceleration profiles without oversizing the cabinet.
This catalog number carries the -ERS suffix, meaning EtherNet/IP servo drive with hardwired Safe Torque Off. It is an active catalog number in Rockwell Automation product data, so you can standardize on it with confidence. At Mronexus, we supply genuine industrial automation parts at below-market prices, backed by worldwide shipping and fast delivery from stock.

Key Features & Technical Specifications
- Input voltage: 342…528V rms three-phase (380…480V AC nominal), 47…63 Hz.
- Control power: 21.6…26.4V DC (24V DC nominal), 0.9 A DC for non-brake motors.
- Continuous output: 6.25 kW at 400V AC, 11.7 A rms (16.5 A 0-pk).
- Peak output: 34.1 A rms (48.3 A 0-pk) for up to 1.0 s.
- Communication: Dual-port EtherNet/IP (PORT1/PORT2 RJ45), integrated motion.
- Operating temperature: 0…50 °C (32…122 °F); storage -35…+70 °C.
- Efficiency: 97 %, with 20 ms line-loss ride-through.
- Safety: Hardwired Safe Torque Off, up to PL d / Cat 3 and SIL CL2.
- Enclosure: IP20, pollution degree 2, for mounting inside a grounded enclosure.
- Dimensions: 225.0 H × 55.0 W × 265.0 D mm; 2.05 kg.
The standout specification is the embedded three-port cut-through Ethernet switch. It supports device-level ring (DLR) and star topologies with a 1.0 ms minimum cyclic update period and 100 ns maximum port-to-port time synchronization variation — a real-world advantage when multiple axes must stay tightly coordinated.
Comparison with Alternative Drive Categories
- vs. analog-command servo drives: the 2198-C4030-ERS integrates motion directly on EtherNet/IP, eliminating separate analog wiring and reducing commissioning time.
- vs. drives without built-in safety: hardwired STO is standard here, so a functional safety circuit can be implemented without an external contactor solution.
- vs. larger frame drives: Frame 2 at 6.25 kW balances power density against cabinet space; higher-power Kinetix 5300 models occupy larger frames.
- vs. separate communication modules: network, I/O and STO connections are built into the housing — no option-card slot is required.

Applications & Use Cases
The 2198-C4030-ERS suits packaging, material handling, converting and assembly machinery where a single axis needs precise, network-integrated control. In a typical converting line, the drive’s 34.1 A peak current supports rapid acceleration during roll changes, while the 20 ms line-loss ride-through helps the axis ride through brief power dips instead of faulting. Because Safe Torque Off is hardwired, maintenance access can be granted with the axis safely disabled while the rest of the machine remains powered.
Compatibility & Integration
The drive is configured with Studio 5000 Logix Designer and operates with Logix 5000 controllers over EtherNet/IP. Feedback options include a dedicated 15-pin MFB connector plus auxiliary feedback for incremental encoders. For CE compliance, the recommended AC line filter is 2198-DBR20-F.
Integration Note: Wiring into an EtherNet/IP network may require an external gateway or connection module depending on your existing architecture. Confirm cables and gateways with the supplier before ordering — CAT5e shielded cable is specified up to 100 m.
Maintenance & Reliability
Frame 2 drives include a cooling fan that runs during control-power startup, when the inverter is enabled, and when inverter temperature exceeds a preset threshold. Inspect the fan and heatsink at scheduled intervals, keep ambient temperature within 0…50 °C, and respect the one-power-cycle-per-minute limitation. These practices protect the 97 % efficiency figure and extend service life — a direct contribution to lower total cost of ownership.
FAQ
Q: What input voltage does the 2198-C4030-ERS require?
A: It accepts 342…528V rms three-phase (380…480V AC nominal) at 47…63 Hz, with 24V DC control power at 21.6…26.4V DC.
Q: Does this drive support Safe Torque Off?
A: Yes. The -ERS suffix denotes hardwired Safe Torque Off, certified up to PL d, Category 3 (ISO 13849) and SIL CL2 (IEC 61508).
Q: Which communication protocol is built in?
A: Dual-port EtherNet/IP with integrated motion, supporting linear, DLR and star topologies. No Modbus or serial port is published for this series.
Q: What is the operating temperature range?
A: 0…50 °C (32…122 °F) operational, with storage from -35…+70 °C. The drive is IP20 and must be mounted inside a grounded enclosure.
Product Support & Availability
The 2198-C4030-ERS is in stock and ready to ship from Mronexus. As your one-stop sourcing base for PLC, HMI, servo, sensor and circuit breaker products, we help you consolidate orders and reduce procurement overhead. Contact Mronexus for genuine industrial automation parts at competitive prices.
Unmatched Customer Service
- After Hours Shipping
- Real Time Order Tracking
- Flexible Delivery Options
- Intact Technical Supports