Skip to content
sales@mronexus.com +86 180 3000 5825 Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China Reply within 24 hours Worldwide shipping

22A-A9P6N103 | Allen-Bradley PowerFlex 4 AC Drive 2.2 kW

PLC

  • Brand: Allen-Bradley
  • Part Number: 22A-A9P6N103
  • Availability: Ask for quote

Genuine Allen-Bradley 22A-A9P6N103 PowerFlex 4 AC drive, 2.2 kW, 200-240V 1-phase, RS-485. Reliable performance for industrial motor control. In stock at Mronexus.

Product Details

Product Introduction

The Allen-Bradley 22A-A9P6N103 is a PowerFlex 4 series AC adjustable-frequency drive designed for reliable motor control in industrial automation. As a discontinued model (official discontinuation date: 2025-06-30), it remains a critical component for many existing systems, and sourcing genuine units is essential for maintaining uptime. The 22A-A9P6N103 delivers 2.2 kW (3 HP) output at 9.6 A, operating from a 200…240V AC single-phase supply. Its built-in RS-485 DSI port supports Modbus RTU communication, enabling integration into supervisory control networks. At Mronexus, we understand the challenges of sourcing legacy automation parts. That’s why we offer genuine industrial automation parts at below-market prices, ensuring you get reliable, value-for-money solutions without compromising on quality. Whether you need a direct replacement or a spare for critical inventory, this drive is available from stock for fast delivery worldwide.

Figure 1: Front view of the Allen-Bradley 22A-A9P6N103 industrial automation component showing its physical design and enclosure.

Key Features & Technical Specifications

  • Power Rating: 2.2 kW (3 HP) output, 9.6 A continuous current, 200…240V AC 1-phase input.
  • Operating Temperature: -10…+50 °C for IP20 open type; derate to +40 °C for NEMA 1.
  • Input Voltage: 200…240V AC ±10%, 50/60 Hz, with 100 ms power ride-through.
  • Communication: Built-in RS-485 DSI port supporting Modbus RTU (function codes 03, 06, 16).
  • Control Method: PWM output with 2…16 kHz carrier frequency, 0…240 Hz output frequency.
  • Overload Capacity: 150% for 60 s, 200% for 3 s, providing robust motor protection.
  • Efficiency: 97.5% typical, reducing energy losses and operating costs.
  • Enclosure: IP20 / NEMA/UL Type Open panel mount; IP30 kit 22-JBAB available separately.
  • I/O: 3 dedicated + 2 programmable digital inputs, 1 analog input, 1 Form C relay output.
  • Dimensions: 180 H × 100 W × 136 D mm, 2.2 kg shipping weight.

A standout feature is the integrated RS-485 DSI port, which allows direct Modbus RTU communication without additional hardware. This enables remote monitoring and control, reducing wiring complexity and installation time in multi-drive systems.

Comparison with Similar Product Categories

When evaluating the 22A-A9P6N103 against other drives in its class, several distinctions emerge:

  • vs. PowerFlex 40: The PowerFlex 40 offers sensorless vector control and higher overload capacity, but the PowerFlex 4 provides simpler, cost-effective operation for basic variable-torque applications.
  • vs. PowerFlex 4M: The 4M is a more compact, global version with similar power ratings, but the 22A-A9P6N103’s panel-mount design and established compatibility make it a preferred choice for existing installations.
  • vs. Modern replacements (25A-A011N104): The official replacement offers enhanced features and efficiency, but the 22A-A9P6N103 remains a drop-in solution for legacy systems, avoiding rewiring and reconfiguration costs.
  • vs. Other brands: Allen-Bradley’s reputation for reliability and widespread support network gives the PowerFlex 4 an edge in uptime-critical operations.

For engineers maintaining existing machinery, the 22A-A9P6N103 provides a balance of proven performance and straightforward integration, making it a reliable choice for replacement and spare parts inventory.

Figure 2: Technical layout and connection details for the Allen-Bradley 22A-A9P6N103 industrial automation component.

Applications & Use Cases

The 22A-A9P6N103 is well-suited for a variety of industrial applications requiring precise speed control of AC motors. Common uses include conveyor systems, where controlled acceleration and deceleration reduce mechanical stress and product damage. In fan and pump applications, the drive’s variable frequency operation delivers significant energy savings by matching motor speed to demand. The built-in Modbus RTU communication allows seamless integration into existing control networks, enabling remote monitoring and adjustments. For legacy systems facing obsolescence, this drive serves as a reliable drop-in replacement, minimizing downtime and avoiding costly retrofits. Its robust overload protection and wide operating temperature range ensure dependable performance in harsh environments, from food processing to material handling.

Installation & Setup

Installing the 22A-A9P6N103 requires attention to proper panel mounting and wiring practices. Ensure the enclosure provides adequate clearance for convection cooling; maintain minimum clearances as specified in the user manual. Connect input power to terminals L1 and L2 (single-phase), and motor leads to T1, T2, and T3. The drive’s digital inputs support both SRC and SNK wiring configurations, offering flexibility with various control devices. For analog speed reference, use the DIP-switch to select between 0…10V and 4…20 mA. The built-in RS-485 port should be wired using shielded twisted-pair cable, with terminating resistors (AK-U0-RJ45-TR1) applied at the network ends. Parameter A103 sets the baud rate (default 9600), and A104 assigns the node address (1…247). For CE compliance, an external L-type filter (22-RF025-CL) is required, as the drive lacks an integral EMC filter.

Maintenance & Reliability

Regular maintenance is key to maximizing the service life of the 22A-A9P6N103. Inspect the heatsink and fan (if equipped) every 6 months for dust accumulation; clean with dry compressed air. Verify terminal connections annually for tightness, as vibration can loosen screws. The drive’s operating temperature range of -10…+50 °C (IP20) requires adequate panel ventilation; ensure ambient conditions remain within limits. The convection-cooled design of lower ratings reduces fan wear, but this 2.2 kW model is fan-cooled, so monitor fan operation. The 100 ms power ride-through and logic ride-through of 0.5 s minimum help prevent nuisance trips during brief voltage sags, enhancing reliability. By following these practices, you can avoid unplanned downtime and extend the drive’s operational life, ensuring value-for-money performance.

Compatibility & Integration

The 22A-A9P6N103 integrates seamlessly with Allen-Bradley control systems and third-party Modbus RTU networks. Its RS-485 DSI port supports multi-drop configurations with up to 32 nodes; beyond that, use RS-485 repeaters. For network integration, the drive can be connected to PLCs, HMIs, and SCADA systems using Modbus RTU function codes 03, 06, and 16. When interfacing with fieldbus networks such as PROFINET or EtherNet/IP, an external gateway or communication module is required, as the drive has no option-card slot. The External DSI Communications Kit 22-XCOMM-DC-BASE accommodates adapters like 22-COMM-E (EtherNet/IP) and 22-COMM-P (PROFIBUS). For remote HMI, the LCD keypads 22-HIM-C2 or 22-HIM-A3 can be connected via DSI cables. Always confirm cable and gateway compatibility with the supplier before installation.

FAQ

Q: What is the recommended replacement for the 22A-A9P6N103?

A: The official engineering replacement is the 25A-A011N104 (PowerFlex 40P series). However, if you require a direct drop-in replacement for an existing PowerFlex 4 installation, the 22A-A9P6N103 is still available from stock at Mronexus.

Q: Can the 22A-A9P6N103 be used with a braking resistor?

A: No, this model (type code 3) does not include a brake IGBT, so dynamic braking is not supported. For applications requiring braking, consider a drive with an integral brake IGBT or an external braking unit.

Q: What communication protocols does the built-in RS-485 port support?

A: The RS-485 DSI port supports Modbus RTU with function codes 03 (Read Holding Registers), 06 (Preset Single Register), and 16 (Preset Multiple Registers). Baud rates range from 1200 to 38400 bit/s, with a default of 9600.

Q: Is the 22A-A9P6N103 CE compliant?

A: Yes, when installed with an external L-type EMC filter (22-RF025-CL) and following the wiring guidelines in the user manual, the drive meets EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU. Without the filter, CE compliance is not achieved.

Q: What is the operating temperature range?

A: The drive operates from -10…+50 °C in IP20 open type. If an IP30/NEMA 1 kit is installed, the maximum ambient temperature is +40 °C. Ensure the atmosphere is free of corrosive gases and dust.

Product Support & Availability

Although the 22A-A9P6N103 is officially discontinued, Mronexus maintains a stock of genuine units for immediate shipment. We understand the urgency of keeping legacy systems running, and our worldwide fast-delivery service ensures you get the parts you need without delay. As your one-stop sourcing base for industrial automation components, we also supply PLCs, HMIs, servo systems, sensors, and circuit breakers. Contact Mronexus for genuine industrial automation parts at competitive prices.

Unmatched Customer Service

  • After Hours Shipping
  • Real Time Order Tracking
  • Flexible Delivery Options
  • Intact Technical Supports

Latest News

Insights, product guides and industry updates from our team.

Need a quote or technical support?

Send us your part numbers and we will get back within 24 hours.