22A-B4P5N104 | Allen-Bradley PowerFlex 4 AC Drive 0.75 kW
PLC
- Brand: Allen-Bradley
- Part Number:
22A-B4P5N104 - Availability: Ask for quote
Genuine Allen-Bradley 22A-B4P5N104 PowerFlex 4 AC drive: 0.75 kW, 200…240V 3-phase, RS-485 Modbus RTU, IP20. In stock at Mronexus for fast delivery.
Product Details
Problem-Solution: Why the 22A-B4P5N104 Remains a Practical Choice for 0.75 kW Applications
When a compact 0.75 kW AC drive fails, engineers face a familiar pain point: finding a genuine replacement that matches the original panel footprint, wiring scheme and control interface without redesigning the enclosure. The Allen-Bradley 22A-B4P5N104, part of the PowerFlex 4 series, addresses this challenge directly. Although official product data lists this catalog number as discontinued (effective 2025-06-30), a substantial installed base remains in service, and sourcing genuine units or the published replacement 25A-B5P0N104 is critical to minimizing downtime. Mronexus supplies genuine industrial automation parts at competitive prices, with worldwide shipping and fast delivery from stock.

Key Technical Specifications: What Matters on the Panel
Each specification below is drawn from the manufacturer’s user manual (22A-UM001L-EN-E) and reflects the parameters most relevant to panel builders and maintenance teams.
- Input voltage: 200…240V AC, 3-phase, ±10% tolerance; input range 180…265V AC.
- Output rating: 0.75 kW (1 HP) at 4.5 A continuous, 0…230V three-phase output.
- Operating temperature: -10…+50 °C for IP20/Open Type; -10…+40 °C with IP30/NEMA 1 kit.
- Power supply: 50/60 Hz input; 2.25 kVA at 5.2 A input current; 10 A branch fuse recommended.
- Communication protocol: Built-in RS-485 DSI port supporting Modbus RTU (function codes 03, 06, 16).
- Control method: PWM output with programmable carrier frequency (2…16 kHz, default 4 kHz).
- Overload capacity: 150% for 60 s, 200% for 3 s; 200% hardware limit, 300% instantaneous fault.
- Efficiency: 97.5% typical; 100 ms faultless power ride-through.
- Enclosure: Panel mount, IP20 / NEMA/UL Type Open; frame size A.
- Dimensions: 152.0 H × 80.0 W × 136.0 D mm; shipping weight 1.4 kg.
The integral brake IGBT is a distinctive feature for this power class, enabling controlled stops when paired with an external resistor (minimum 60 Ω). The built-in RS-485 port eliminates the need for an add-on communication card, simplifying integration into existing Modbus networks.
Installation and Setup: Avoiding Common Pitfalls
Panel builders often encounter two pain points during installation: inadequate thermal clearance and incorrect DIP-switch configuration for analog inputs. The 22A-B4P5N104 is convection cooled at 0.2 kW ratings but fan cooled at 0.75 kW, so ensure unobstructed airflow around the heatsink. Mount the drive vertically on a flat panel, respecting the published dimensions (152 × 80 × 136 mm). For IP30/NEMA 1 protection, field-install kit 22-JBAA; note that this reduces the maximum ambient temperature to +40 °C. The analog input is DIP-selectable for 0…10V DC or 4…20 mA; verify the switch position before power-up to avoid signal scaling errors. Digital inputs accept 18…24V DC in SRC mode or 0…6V DC in SNK mode, with 6 mA input current.

Communication and Integration: Modbus RTU Without Extra Hardware
A frequent integration challenge is connecting a compact drive to a plant network without adding costly option cards. The 22A-B4P5N104 solves this with its built-in RS-485 DSI port, which supports Modbus RTU natively. Parameters A103 (baud rate, 1200…38400 bit/s), A104 (node address, 1…247) and A107 (RTU 8-N-1 format) configure the network. For networks exceeding 32 nodes, RS-485 repeaters may be required. No communication option-card slot is published for the PowerFlex 4; however, the External DSI Communications Kit 22-XCOMM-DC-BASE allows mounting of 22-COMM adapters for other protocols. When wiring into fieldbus networks such as PROFINET or EtherNet/IP, an external gateway or connection module may be required; confirm cable and gateway compatibility with the supplier before ordering. For local control, the fixed LED keypad provides start/stop and parameter access without additional hardware.
Maintenance and Reliability: Extending Service Life
Downtime costs accumulate quickly in continuous processes. To maximize reliability, inspect the drive every 6–12 months: check fan operation (fan-cooled at 0.75 kW), clean heatsink fins, and verify terminal torque. The operating environment must be free of volatile or corrosive gases, vapors and dust; relative humidity should remain 0…95% non-condensing. The drive withstands 15 g shock and 1 g vibration (5…2000 Hz) during operation. The 100 ms power ride-through and 0.5 s logic control ride-through (2 s typical) reduce nuisance trips during brief supply disturbances. For dynamic braking, inspect the external brake resistor periodically; the published minimum is 60 Ω with a 5% duty cycle (AK-R2-091P500).
Replacement and Upgrade Path: Planning for Obsolescence
With the 22A-B4P5N104 officially discontinued, maintenance teams should plan a migration strategy. Rockwell Automation publishes the 25A-B5P0N104 as the engineering replacement. Before swapping, document existing parameter settings, verify the replacement’s terminal layout and confirm that the enclosure dimensions and mounting holes align. The 25A series may offer different communication options and I/O configuration; consult the respective datasheet. For urgent repairs, genuine 22A-B4P5N104 units may still be available through specialized distributors. Mronexus maintains a one-stop sourcing base for PLC, HMI, servo, sensor and circuit breaker needs, helping engineers secure genuine parts at competitive prices with fast delivery from stock.
Frequently Asked Questions
Q: What is the operating temperature range of the 22A-B4P5N104?
A: The drive operates from -10 to +50 °C in IP20/Open Type configuration. With the optional IP30/NEMA 1 kit (22-JBAA), the upper limit is +40 °C. Storage temperature is -40 to +85 °C.
Q: Can the 22A-B4P5N104 communicate over Modbus RTU?
A: Yes. The built-in RS-485 DSI port supports Modbus RTU with function codes 03, 06 and 16. Node addresses range from 1 to 247, and baud rates are selectable from 1200 to 38400 bit/s (default 9600).
Q: What replacement drive is recommended for the discontinued 22A-B4P5N104?
A: Rockwell Automation publishes the 25A-B5P0N104 as the engineering replacement. Verify wiring, parameter migration and mechanical fit before commissioning. Contact Mronexus for genuine replacement parts and migration support.
Q: Does the 22A-B4P5N104 include an EMC filter or brake resistor?
A: No integral EMC filter is fitted; external filters 22-RF9P5-AS or 22-RF9P5-AL are required for CE compliance. An integral brake IGBT is included, but dynamic braking requires an external resistor (minimum 60 Ω, e.g. AK-R2-091P500).
For genuine industrial automation parts, contact Mronexus today. We ship worldwide from stock, ensuring reliable, value-for-money components for your critical applications.
Unmatched Customer Service
- After Hours Shipping
- Real Time Order Tracking
- Flexible Delivery Options