Skip to content
sales@mronexus.com +86 180 3000 5825 Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China Reply within 24 hours Worldwide shipping

25C-B8P0N104 | Allen-Bradley PowerFlex 527 2HP EtherNet/IP Drive

PLC

  • Brand: Allen-Bradley
  • Part Number: 25C-B8P0N104
  • Availability: Ask for quote

Allen-Bradley 25C-B8P0N104 PowerFlex 527 AC drive: 2 HP, 200-240V 3-phase, dual EtherNet/IP, integrated STO safety. Reliable performance for demanding industrial motion control.

Product Details

Model: 25C-B8P0N104

Brand: Allen-Bradley (Rockwell Automation)

Series: PowerFlex 527 AC Drive (PowerFlex 520 Series)

PowerFlex 527 AC drive, member of the PowerFlex 520-series platform, 200…240V AC, 3-phase input, 1.5 kW (2 HP) normal duty and 1.5 kW (2 HP) heavy duty at 8.0 A, Frame A, IP20 NEMA/Open Type, no integral EMC filter, embedded dual-port EtherNet/IP and integrated safety.

── Hardware ──

Product type: AC adjustable-frequency drive — PowerFlex 527, a member of the PowerFlex 520-series platform (catalog prefix 25C) (per 520-UM002F-EN-E p. 1 (title page: PowerFlex 527 Adjustable Frequency AC Drive, Bulletin Number 25C) and p. 10, Catalog Number Explanation)

Drive family: PowerFlex 520 Series; PowerFlex 527 is one of the three members (523, 525, 527) — there is no standalone “PowerFlex 520” catalog prefix (per 520-UM002F-EN-E p. 8, Preface — “The PowerFlex 527 AC drive belongs to the new generation of PowerFlex 520-series drives, which also consist of PowerFlex 523 and PowerFlex 525 drives”)

Catalog number structure: 25C-B8P0N104: drive 25C, voltage code B (200…240V AC), rating code 8P0, enclosure N = IP20 NEMA/Open, interface module 1 = Standard, EMC filter 0 = No Filter, braking 4 = Standard (brake IGBT) (per 520-UM002F-EN-E p. 10, Catalog Number Explanation)

Drive voltage class: 200…240V AC, 3-phase (per 520-UM002F-EN-E pp. 127…128, Table 2 — PowerFlex 527 Drive Ratings, row 25C-B8P0N104)

Enclosure / mounting: IP20 NEMA/Open Type, panel mount; IP30 / NEMA 1 / UL Type 1 requires the 25-JBAx option kit. Frames A…C accept DIN-rail or screw mounting; frames D and E are screw mounted only (per 520-UM002F-EN-E p. 118, Environmental Specifications (mounting and DIN rail notes))

Frame size: A (per 520-UM002F-EN-E p. 8, Preface — Drive Frame Sizes; the catalog-number to frame-size cross-reference is published in Appendix B, p. 127)

Control method: sinusoidal PWM; control methods: Basic Volts/Hertz, Fan/Pump Volts/Hertz, sensorless vector control, SVC Economizer, and closed-loop position or velocity control with the 25-ENC-2 encoder option (per 520-UM002F-EN-E p. 120, Control Specifications — Method)

Carrier frequency: 2…8 kHz; published drive rating is based on 4 kHz (per 520-UM002F-EN-E p. 120, Control Specifications)

Human interface: standard interface module with integral keypad, potentiometer and LED display (per 520-UM002F-EN-E p. 10 (interface module code 1 = Standard))

Integral EMC filter: no integral EMC filter (catalog EMC-filter digit 0); external filters provide EN 61800-3 Category C1/C2/C3 compliance (per 520-UM002F-EN-E p. 10 (EMC filter / emission class code) and 520-TD001I-EN-E p. 25, RF Emission Compliance)

Braking: integral brake IGBT fitted (catalog braking digit 4); dynamic braking requires an external brake resistor (per 520-UM002F-EN-E p. 10 (Braking code 4 = Standard))

Internal DC bus choke: “Only for Frame E drive ratings” for the 200…240V AC input class, and this catalog number is Frame A (so it falls outside that entry) (per 520-UM002F-EN-E p. 119, Technical Specifications)

Cooling: fan cooled; optional Control Module Fan Kit 25-FANx-70C raises the maximum surrounding air temperature to 70 °C (per 520-UM002F-EN-E p. 118, Control Module Fan kit note and 520-TD001I-EN-E p. 17 (Ambient Operating Temperatures))

Encoder feedback: 25-ENC-2 incremental encoder option board, 5V/12V, 250 mA supply (per 520-UM002F-EN-E p. 120, Encoder Specifications (25-ENC-2 incremental encoder option))

── Drive Ratings ──

Rated output power — Normal Duty: 1.5 kW (2 HP) (per 520-UM002F-EN-E pp. 127…128, Table 2 — PowerFlex 527 Drive Ratings, row 25C-B8P0N104)

Rated output power — Heavy Duty: 1.5 kW (2 HP) (per 520-UM002F-EN-E pp. 127…128, Table 2 — PowerFlex 527 Drive Ratings, row 25C-B8P0N104)

Continuous output current: 8.0 A maximum at rated output voltage (per 520-UM002F-EN-E pp. 127…128, Table 2 — PowerFlex 527 Drive Ratings, row 25C-B8P0N104)

Output voltage: 0 V to rated motor voltage (three-phase output at terminals T1, T2 and T3) (per 520-UM002F-EN-E p. 120, Control Specifications — Output Voltage Range)

Output frequency: 0…590 Hz (programmable) (per 520-UM002F-EN-E p. 120, Control Specifications)

Intermittent overload — Normal Duty: 110 % of rated output current for up to 60 s, 150 % for up to 3 s (per 520-UM002F-EN-E p. 121, Control Specifications (continued)) — this catalog number is not named in the published Normal Duty list (520-UM002F-EN-E p. 121)

Intermittent overload — Heavy Duty: 150 % of rated output current for up to 60 s, 180 % for up to 3 s (per 520-UM002F-EN-E p. 121, Control Specifications (continued)) — the published p. 121 list names this catalog number under the Heavy Duty values

Efficiency: 97.5 % (typical) (per 520-UM002F-EN-E p. 120, Control Specifications)

Speed regulation — no encoder: V/Hz ±1 % of base speed across a 60:1 range; SVC and SVC Economizer ±0.5 % across a 100:1 range; with encoder: ±0.1 % of base speed across a 100:1 range (per 520-UM002F-EN-E p. 120, Control Specifications)

Frequency accuracy: within ±0.05 % of set output frequency — the PowerFlex 527 table publishes a single figure, without the separate digital-input, analog-input and analog-output accuracies given for the PowerFlex 523 (per 520-UM002F-EN-E p. 120, Control Specifications)

Figure 1: Front view of the Allen-Bradley 25C-B8P0N104 industrial automation component showing its physical design and enclosure.

Accel/decel: programmed as a “REAL” tag through the Studio 5000 motion instructions; the manual refers the user to the Logix 5000 Controllers Motion Instructions Reference Manual, publication MOTION-RM002, and does not publish a time range or increment for the PowerFlex 527 (per 520-UM002F-EN-E p. 121, Control Specifications (continued))

Stop modes: multiple programmable stop modes including Disable and Coast, Current Decel and Disable, and Ramped Decel and Disable (per 520-UM002F-EN-E p. 120, Control Specifications)

── Control I/O ──

Digital inputs: 4 programmable; 24V DC; SRC mode 18…24V DC = ON / 0…6V DC = OFF; SNK mode 0…6V DC = ON / 18…24V DC = OFF (per 520-UM002F-EN-E pp. 121…122)

Analog inputs: 2 isolated, –10…+10V DC or 4…20 mA; 10-bit resolution; 100 kΩ voltage / 250 Ω current input impedance (per 520-UM002F-EN-E pp. 121…122)

Relay outputs: 2 — 1 Form A + 1 Form B, programmable; 3.0 A resistive / 0.5 A inductive at 30V DC, 125V AC and 240V AC (per 520-UM002F-EN-E pp. 121…122)

Opto outputs: 2 programmable, 30V DC / 50 mA non-inductive (per 520-UM002F-EN-E pp. 121…122)

Analog output: 1 non-isolated, 0…10V or 0…20 mA; 10-bit resolution (per 520-UM002F-EN-E pp. 121…122)

Encoder input: 25-ENC-2 option board; incremental, dual-channel; 5V or 12V, 250 mA supply (per 520-UM002F-EN-E pp. 121…122)

Safe Torque Off: hardwired STO input, TÜV Rheinland approved up to Performance Level e (PLe), Category 3 according to EN ISO 13849 and SIL CL 3 according to IEC 61508, EN 61800-5-2 and EN 62061; STO function response time is less than 12 ms (per 520-UM002F-EN-E pp. 77…78)

── Communication ──

Built-in ports: dual embedded EtherNet/IP ports connect the drive to the network (per 520-UM002F-EN-E p. 45)

Built-in communication: two embedded EtherNet/IP ports and no RS-485 DSI port — the PowerFlex 527 manual publishes no Modbus RTU interface for this family member (520-UM002F-EN-E contains no Modbus or RS-485 provision; the 523 and 525 DSI/Modbus appendix is 520-UM001O-EN-E pp. 205…207), and 520-UM002F-EN-E does not publish a communication option-card slot for the PowerFlex 527

Network topologies: linear, star and Device Level Ring (DLR) are supported; the CIP Safety protocol allows safety data and standard control data and diagnostics to be transmitted simultaneously over the same network (per 520-UM002F-EN-E p. 45)

Integrated motion: the embedded EtherNet/IP ports enable communication with a Logix-based control system for drive control using CIP Motion commands; a safety or non-safety ControlLogix controller must also use a 1756-EN2T, 1756-EN2TR or 1756-EN3TR EtherNet/IP module, while a CompactLogix 5370 controller has dual embedded EtherNet/IP ports (per 520-UM002F-EN-E pp. 45, 48)

Communication option cards: 520-TD001I-EN-E p. 38 lists the 520-series communication adapters 25-COMM-D DeviceNet, 25-COMM-E2P dual-port EtherNet/IP, 25-COMM-P PROFIBUS DP-V1 and 25-COMM-PNET2P PROFINET; accessory cards are supported without affecting the drive footprint and the published card counts are one for PowerFlex 523 and two for PowerFlex 525 (520-TD001I-EN-E p. 3)

Accessories: 1203-USB converter module is listed for the 520 series; the 22-SCM-232 serial converter module, 22-RJ45CBL-C20 DSI cable and AK-U0-RJ45-TR1 terminating resistors are listed for the RS-485 DSI network, which the PowerFlex 527 does not provide (per 520-TD001I-EN-E pp. 38…39)

── Electrical ──

Supply voltage: 200…240V AC, 3-phase (per 520-UM002F-EN-E pp. 127…128, Table 2 — PowerFlex 527 Drive Ratings, row 25C-B8P0N104)

Input voltage tolerance: -15 % / +10 % (per 520-UM002F-EN-E p. 119, Technical Specifications — Protection and Electrical, Voltage Tolerance)

Input frequency: 47…63 Hz (per 520-UM002F-EN-E p. 119, Technical Specifications — Electrical, Frequency Tolerance)

Input phases: three-phase input provides the full rating; single-phase input on a three-phase drive provides 35 % of the rating (per 520-UM002F-EN-E p. 119, Electrical Specifications — Input Phases)

Displacement power factor: 0.98 across the entire speed range (per 520-UM002F-EN-E p. 119, Electrical Specifications — Displacement Power Factor)

Maximum short-circuit rating: 100,000 A symmetrical (the actual short-circuit rating is determined by the AIC rating of the installed fuse or circuit breaker) (per 520-UM002F-EN-E p. 119, Electrical Specifications — Short Circuit Rating)

DC bus overvoltage trip: 405 V DC bus, published as equivalent to 290 V AC incoming line under the 200…240V AC AC Input row (per 520-UM002F-EN-E p. 119, Technical Specifications — Bus Overvoltage Trip)

DC bus undervoltage trip: 190 V DC bus, published as equivalent to 150 V AC incoming line under the 200…240V AC AC Input row (per 520-UM002F-EN-E p. 119, Technical Specifications — Bus Undervoltage Trip)

Power ride-through: 100 ms (per 520-UM002F-EN-E p. 119, Technical Specifications — Protection, Power Ride-through)

Logic control ride-through: 0.5 s minimum, 2 s typical (per 520-UM002F-EN-E p. 119, Technical Specifications — Protection, Logic Control Ride-through)

Overcurrent: 200 % hardware limit, 300 % instantaneous fault (per 520-UM002F-EN-E p. 119, Technical Specifications — Protection, Overcurrent)

Transistor type: insulated gate bipolar transistor (IGBT) (per 520-UM002F-EN-E p. 119, Electrical Specifications — Transistor Type)

Figure 2: Technical layout and connection details for the Allen-Bradley 25C-B8P0N104 industrial automation component.

Electronic motor overload protection: provides class 10 motor overload protection according to NEC article 430 and motor over-temperature protection according to NEC article 430.126(A)(2); UL 508C File 29572 (per 520-UM002F-EN-E p. 119, Technical Specifications — Protection, Electronic Motor Overload Protection (class 10, NEC article 430, UL 508C File 29572))

Ground fault trip: phase-to-ground on the drive output; short-circuit trip: phase-to-phase on the drive output (per 520-UM002F-EN-E p. 119, Technical Specifications — Protection, Ground Fault Trip and Short Circuit Trip)

Power dissipation: 79 W total at rated load, rated speed and the PWM setting (per 520-UM002F-EN-E pp. 122…123, Power Specifications — Watts Loss (PowerFlex 527 Estimated Watts Loss), 8.0 A row of the 200…240V block)

Electrical specification source: the entries above are taken from the Technical Specifications table in 520-UM002F-EN-E p. 119, Technical Specifications

── Environmental ──

Operating temperature (ambient minimum -20 °C for every mounting method): vertical, IP20/Open Type -20…+50 °C without derating, up to +60 °C derated and up to +70 °C derated with the 25-FANx-70C control module fan kit — the derated maximum is taken from the Environmental Specifications table on p. 118 because the Ambient Operating Temperatures table on p. 12 prints an em-dash in its Maximum (Derate) column for every IP20 mounting method, so p. 118 is the only published figure for that cell; vertical with zero stacking, IP20/Open Type 45 °C without derating and 65 °C with the fan kit; IP30/NEMA 1/UL Type 1 (requires the 25-JBAx kit) 45 °C without derating and 55 °C derated, no fan-kit value published; horizontal with the fan kit 50 °C without derating and 70 °C with the kit; horizontal with zero stacking and the fan kit 45 °C and 65 °C respectively; the manual publishes no IP30 zero-stacking row for the PowerFlex 527 (per 520-UM002F-EN-E p. 12, Ambient Operating Temperatures and p. 118, Environmental Specifications)

Storage temperature: -40…+85 °C (-40…+185 °F) — the table publishes -40…+70 °C for Frame E (per 520-UM002F-EN-E p. 118, Environmental Specifications)

Relative humidity: 0…95 % non-condensing (per 520-UM002F-EN-E pp. 118…119)

Pollution degree: installation in a pollution degree 1 or 2 environment is required for compliance with the CE Low Voltage Directive and UK LV Regulations; all enclosures are acceptable (per 520-UM002F-EN-E pp. 118…119 and 520-UM002F-EN-E p. 33)

Shock: 15 g (operating) and 30 g (non-operating, transportation) peak force for Frame A; complies with IEC 60068-2-27 (per 520-UM002F-EN-E pp. 118…119). No pulse duration is published for this series.

Vibration: 2 g (operating) and 2.5 g (non-operating, transportation) for Frame A; complies with IEC 60068-2-6:2007 (per 520-UM002F-EN-E pp. 118…119)

Sound pressure level: 53 dBA (Frames A and B), 57 dBA (Frame C), 64 dBA (Frame D), 68 dBA (Frame E), measured 1 m (3.3 ft) from the drive (per 520-UM002F-EN-E pp. 118…119)

Altitude: 1000 m (3300 ft) maximum without derating; up to 4000 m (13 200 ft) with derating, except 600V drives limited to 2000 m (6600 ft); 600V drives may only be used on a center-grounded supply system up to and including 2000 m (per 520-UM002F-EN-E pp. 118…119 and 520-UM002F-EN-E p. 35)

Conformal coating: complies with IEC 60721-3-3 level 3C2 (chemical and gases only) (per 520-UM002F-EN-E pp. 118…119); the ambient atmosphere must not contain volatile or corrosive gases, vapors or dust

── Physical ──

Dimensions (H×W×D): 152.0 H × 72.0 W × 172.0 D mm (Frame A, per 520-UM002F-EN-E (Sep 2025) p. 135 (Table 15); the same frame values are published in 520-TD001I-EN-E)

Weight: 1.1 kg (Frame A, drive weight per 520-UM002F-EN-E (Sep 2025) p. 135 (Table 15) — the official column is headed “Weight (kg/lb)” under the Drive Weight table; net vs shipping basis is not specified by the manufacturer)

── Certifications ──

Agency certification: c-UL-us Listed to UL 508C and CSA C22.2 No. 274, and Listed to UL 61800-5-1 and CSA C22.2 No. 274-17 (520-UM002F-EN-E p. 117)

RCM: Australian Communications and Media Authority, in conformity with the Radiocommunications Act 1992 (including amendments up to 2018), the Radiocommunications (Electromagnetic Compatibility) Standard 2017 and the Radiocommunications Labeling (Electromagnetic Compatibility) Notice 2017, applying EN 61800-3 (520-UM002F-EN-E pp. 117…118)

CE: declared to Low Voltage Directive 2014/35/EU, EMC Directive 2014/30/EU, Machinery Directive 2006/42/EC, RoHS Directive 2011/65/EU and Ecodesign Directive 2009/125/EC, to standards EN 61800-3 and EN 61800-5-1 (520-UM002F-EN-E p. 117)

UKCA: in conformity with Electrical Equipment (Safety) Regulations 2016 No. 1101, Electromagnetic Compatibility Regulations 2016 No. 1091, Equipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres Regulations 2016 No. 1107, Supply of Machinery (Safety) Regulations 2008 No. 1597, Restriction of the Use of Certain Hazardous Substances Regulations 2012 No. 3032 and Ecodesign for Energy-Related Products and Energy Information Regulations 2021 No. 745, applying EN 61800-3 and EN 61800-5-1 (520-UM002F-EN-E pp. 117…118)

KC: KCC — Korean Registration of Broadcasting and Communications Equipment, compliant with Article 58-2 of the Radio Waves Act, Clause 3 (520-UM002F-EN-E pp. 117…118)

Ecodesign: the PowerFlex 527 is listed on p. 2 of PFLEX-TD003H-EN-P among the PowerFlex families that are within the scope of Ecodesign Regulation (EU) 2019/1781 and UK SI 2021 No. 745 and meet or exceed the IE2 efficiency class those regulations require; the CDM loss table on p. 76 publishes for the 240V class 1.5 kW rating (a row printed under the “Frame A” heading, rated output current 8 A, rated apparent power 3.2 kVA) an overall complete-drive-module loss of 104.4 W at the (90 % speed, 100 % torque) operating point = 55.6 % of the IEC reference drive loss at that point, the IE2 test requiring the CDM loss to be at least 25 % below that reference, which is 3.3 % of the rated apparent power, with standby losses of 1.6 % of rated apparent power (PFLEX-TD003H-EN-P pp. 76…83). SUG-14: the “Frame A” heading in PFLEX-TD003H is a CDM-loss table column label and must not be read as the drive’s mechanical frame size

Seismic: tested by Trentec to be compliant with AC156 Acceptance Criteria for Seismic Qualification Testing of Nonstructural Components and the 2003 International Building Code worst-case seismic level for the USA excluding site class F (520-UM002F-EN-E pp. 117…118)

Surge immunity: certified compliant with SEMI F47 and IEC 61000-4-34 by the Electric Power Research Institute (520-UM002F-EN-E p. 118)

RoHS: compliant with the European Restriction of Hazardous Substances Directive 2011/65/EU; the drive is also designed to meet the appropriate portions of NFPA 70 (US National Electrical Code) and NEMA ICS 7.1 (per 520-UM002F-EN-E p. 117, Certifications — 2011/65/EU RoHS Directive)

Leakage current and earthing: the drive produces leakage current in the protective earthing conductor exceeding 3.5 mA AC and/or 10 mA DC, so the earthing conductor must comply with local regulations for high protective-earthing-current equipment (520-UM002F-EN-E p. 35)

Input current harmonics: the drive generates harmonic current emissions on the AC supply system and, when operated on a public low-voltage network, it is the responsibility of the installer or user to verify that the applicable requirements of the distribution network operator are met; consultation with the network operator and Rockwell Automation may be necessary. No per-catalog-number total harmonic distortion (THD) figure or harmonic spectrum is published for the PowerFlex 520 series, and no EN 61000-3-2 or IEC 61000-3-12 compliance statement is made in the manual (per 520-UM002F-EN-E p. 35, Chapter 1 Installation/Wiring, General Considerations — harmonic current emissions on the AC supply system)

ATEX: TÜV 15 ATEX 7696 X and TUV 21 UKEX 7033 X — certified to ATEX Directive 2014/34/EU and to the UK Equipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres Regulations 2016 No. 1107 for Group II Category (2) GD applications with ATEX approved motors (520-UM002F-EN-E p. 117)

ODVA: conformance tested to EtherNet/IP specifications (520-UM002F-EN-E p. 118)

Lloyd’s Register: Type Approval Certificate 15/80016(E1) (520-UM002F-EN-E p. 118)

IEEE P1668: the product meets the requirements of IEEE P1668 (520-UM002F-EN-E p. 118)

Functional safety: TÜV Rheinland certified with the embedded Safe Torque Off function to ISO 13849-1 SIL 3 / PLe, and to EN 61800-5-2 and EN 62061 SIL 3 / PLe with the Network Torque Off function; standards applied also cover EN ISO 13849-1, EN 60204-1 and IEC 61508 Parts 1-7. The drive is approved for use up to Performance Level e (PLe), Category 3 per EN ISO 13849 and SIL CL 3 per IEC 61508, EN 61800-5-2 and EN 62061; STO response time is less than 12 ms (520-UM002F-EN-E pp. 77…78, 117)

Additional EMC installation conditions: not intended for public low-voltage networks supply domestic premises — without additional mitigation radio frequency interference is expected; the installer is responsible for supplementary line filtering and enclosure measures, and for verifying that the distribution network operator requirements are met (520-UM002F-EN-E p. 35)

Cybersecurity: no Achilles Field Coupled Test Method certification level, no IEC 62443 security provision or capability level and no CIP Security, encrypted-session or authentication feature is published for the PowerFlex 527 in 520-TD001I-EN-E, 520-UM001O-EN-E or 520-UM002F-EN-E — the names “Achilles”, “62443” and “CIP Security” do not occur anywhere in the three publications, and their certification tables (520-TD001I-EN-E p. 13, 520-UM001O-EN-E p. 167 and 520-UM002F-EN-E pp. 117…118) carry no security row; the embedded and adapter EtherNet/IP ports are documented for wiring and network configuration only, and no security document is referenced by the reference-materials tables of the three publications

── Source Provenance ──

Source tier: Primary — manufacturer-published technical documentation only (Allen-Bradley / Rockwell Automation publications)

Publications cited by this record: 3 — 520-UM002F-EN-E (Sep 2025, 160 pages); 520-TD001I-EN-E (Sep 2025, 54 pages); 520-UM001O-EN-E (Sep 2025, 274 pages)

Document types: Technical Data publications, User Manuals

Cross-check: two or more independent official publications agree on this record

Specification lines: 85 (counted over the specification sections only; the 6 Data Notes lines and the lifecycle keys are excluded). Lines carrying both a publication code and a printed page, table or figure anchor: 84 of 85 (99 %); publication code without a page anchor: 0 (0 %); no publication code at all: 1 (1 %). Counting rule: a line is anchored when it matches a publication code and one of “p. “, “pp. …“, “Table “, “Figure ” or “Appendix “.

Published-but-absent items recorded as explicit negative findings: 6 (each names the publication and the pages searched)

Field-level attribution — vendor catalogue data: Rockwell Automation product data (official vendor product catalogue) supplies the catalog-number attributes and the lifecycle status. Fields that carry it: none. Every other field is attributed inside the line itself, in the form “(per p. …)”, so the source of each individual value is readable from the value, not only from this section.

Non-official sources: none. No distributor listing, no reseller dataset, no encyclopaedic or community source and no vendor marketing copy is used.

Derivation policy: values are transcribed from published tables only; frame-level values are disclosed as frame-level rather than per-catalog; where two official publications state different values the record adopts one, states the adopted value, and gives the reason (page role, majority of sources, or rating-code agreement); typographical errors in the source are reproduced and flagged rather than corrected silently.

Cross-document conventions: PFLEX-TD003H-EN-P CDM tables label the 0.5 HP / 5 HP ratings as 0.37 kW / 3.7 kW vs 0.4 kW / 4.0 kW in the drive-ratings tables; the record always carries the drive-ratings value, while the Ecodesign line quotes the CDM-loss row under the label that publication prints

Reference date: verified 2026-10 against the current revision of every cited publication

── Data Notes ──

“PowerFlex 520 Series” is the platform name for the 523, 525 and 527 drives; each catalog number belongs to one concrete member (25A = 523, 25B = 525, 25C = 527). No catalog prefix “25x” without a member letter exists.

Dimensions and weight are frame-level values; all catalog numbers in a frame share the same envelope. Ratings are from 520-UM002F-EN-E (Sep 2025) pp. 127…130 (Table 2); the dimension drawing for Frame A is published in 520-UM002F-EN-E (Sep 2025) p. 135 (Table 15) and the frame weight table in 520-UM002F-EN-E (Sep 2025) p. 135 (Table 15).

The 520-TD001I-EN-E p.25 RF-emission table prints the Category C1 external-filter motor cable limit as “30 m (16 ft)”; 30 m is approximately 98 ft, so the imperial figure appears to be a typographical error. Only the metric value is used here.

Certification applicability: the PowerFlex 527 certification table is published in 520-UM002F-EN-E pp. 117…118 and is separate from the 520-TD001I-EN-E p. 13 table for the 523 and 525. It lists both c-UL-us listings and its own ATEX certificate (TÜV 15 ATEX 7696 X) and Lloyd’s Register certificate 15/80016(E1), which differ from the PowerFlex 525 certificates (TÜV 12 ATEX 7199 X and 12/10068(E1)); the 523 column carries neither.

Sources: 520-UM002F-EN-E (Sep 2025) for drive ratings, dimensions, weights and model-specific functions; 520-TD001I-EN-E (Sep 2025) for family-level specifications, accessories and certifications; Rockwell Automation product data (2026-10) for catalog-number attributes and lifecycle status.

Page-level locations: certification table 520-UM002F-EN-E pp. 117…118; control specifications 520-UM002F-EN-E p. 120, Control Specifications; harmonic and EMC installation conditions 520-UM002F-EN-E p. 35; integrated Safe Torque Off chapter pp. 77…78 and embedded EtherNet/IP description p. 45.

Commercial data (price, stock, lead time, distributor, MOQ, HS code, country of origin) is outside the scope of this technical record and is intentionally absent.

── Lifecycle ──

Current: active catalog number in the official Rockwell Automation product data; no discontinuation date published (Last verified: 2026-10)

Replacement: No replacement classification (active product; no discontinuation published)

Discontinuation Date: N/A (active product)

Unmatched Customer Service

  • After Hours Shipping
  • Real Time Order Tracking
  • Flexible Delivery Options
  • Intact Technical Supports