Skip to content
sales@mronexus.com +86 180 3000 5825 Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China Reply within 24 hours Worldwide shipping

3RW4427-1BC44 | Siemens SIRIUS Soft Starter 93 A / 45 kW

PLC

  • Brand: Siemens
  • Part Number: 3RW4427-1BC44
  • Availability: Ask for quote

Siemens 3RW4427-1BC44 SIRIUS soft starter: 93 A, 45 kW at 400 V, integrated bypass, inside-delta up to 90 kW. Reliable motor control for demanding industrial applications.

Product Details

Product Introduction

When a 45 kW motor trips offline unexpectedly, the cost goes far beyond the repair itself—production halts, schedules slip, and maintenance teams scramble. The Siemens 3RW4427-1BC44 SIRIUS soft starter is engineered to prevent exactly that scenario. As part of the proven SIRIUS family, this soft starter delivers reliable, gradual motor acceleration and deceleration, reducing mechanical stress and electrical spikes that shorten equipment life. With a standard rating of 93 A at 40 °C and 45 kW at 400 V, it handles demanding three-phase motor applications with ease. For higher power needs, the inside-delta circuit configuration raises capacity to 161 A and 90 kW. Whether you’re upgrading an existing installation or specifying new equipment, this soft starter combines robust protection with straightforward integration—a genuine industrial automation component available at competitive prices from Mronexus.

Figure 1: Front view of the Siemens 3RW4427-1BC44 industrial automation component showing its physical design and enclosure.

Key Features & Technical Specs

  • Rated operating current: 93 A at 40 °C (standard circuit); 82 A at 50 °C; 72 A at 60 °C.
  • Inside-delta rated current: 161 A at 40 °C; 142 A at 50 °C; 125 A at 60 °C.
  • Motor power: 45 kW at 400 V standard; 90 kW at 400 V inside-delta.
  • Operating voltage: 200–460 V AC, with -15%/+10% tolerance.
  • Control supply voltage: 230 V AC at 50/60 Hz (tolerance -15%/+10%).
  • Integrated bypass contact system reduces heat dissipation during run.
  • Intrinsic device protection, motor overload protection, and thermistor evaluation.
  • Adjustable current limitation and external reset for flexible commissioning.
  • Screw terminals for main and control circuits; wire length up to 500 m.
  • Operating temperature: up to 60 °C; storage: -25 to +80 °C.

The integrated bypass contact system is a standout feature: once the motor reaches full speed, the thyristors are bypassed, cutting power losses to a typical 55 W at 40 °C. This not only saves energy but also extends the soft starter’s service life by reducing thermal stress on the semiconductors.

Applications & Use Cases

The 3RW4427-1BC44 excels in applications where controlled motor starting is critical. In water treatment plants, it prevents water hammer by gradually ramping pump speed, protecting piping and valves. For conveyor systems, the adjustable current limitation ensures smooth acceleration of heavy loads without belt slippage or mechanical shock. HVAC installations benefit from the soft starter’s ability to reduce starting current, lowering demand charges and extending compressor life. In inside-delta configuration, the higher 90 kW rating makes it suitable for larger compressors, mixers, and crushers where direct-on-line starting would cause unacceptable voltage dips. Across these diverse use cases, the common thread is reliability: the soft starter’s comprehensive protection features—including thermistor evaluation and overload protection—safeguard both the motor and the process, minimizing unplanned downtime.

Figure 2: Technical layout and connection details for the Siemens 3RW4427-1BC44 industrial automation component.

Installation & Setup

Mounting the 3RW4427-1BC44 is straightforward thanks to its screw-fixing design and flexible orientation. The device can be rotated ±90° on a vertical surface and tilted ±22.5° forward or backward, allowing adaptation to tight panel layouts. Maintain the required clearances: 100 mm above, 75 mm below, and 5 mm to the sides for adequate heat dissipation. Wiring is via box terminals for the main circuit and screw terminals for control, accommodating conductor sizes from 2.5 to 70 mm² (stranded). For inside-delta connection, follow the dedicated wiring diagram to ensure correct phase sequencing. The control supply requires 230 V AC at 50/60 Hz; verify voltage tolerance before energizing. With a maximum wire length of 500 m, remote motor connections are feasible without signal degradation. Always consult the official datasheet for detailed torque specifications and terminal assignments.

Maintenance & Reliability

Designed for long-term operation, the 3RW4427-1BC44 requires minimal maintenance. Periodic inspection should focus on terminal tightness, dust accumulation, and ambient temperature. Because the integrated bypass contactor carries current during normal run, wear is limited to the contactor’s mechanical life—typically hundreds of thousands of operations. In dirty or humid environments, ensure the enclosure provides adequate protection (the device itself is IP00, so it must be installed in a suitable cabinet). The soft starter’s thermal management is robust: it operates up to 60 °C ambient, but derating applies above 40 °C. By preventing motor overloads and monitoring thermistor inputs, it actively contributes to reducing downtime and extending the service life of the entire drive train—a key factor in lowering total cost of ownership.

Compatibility & Integration

The 3RW4427-1BC44 integrates seamlessly with standard three-phase motors and control systems. It provides three NO auxiliary contacts and one CO contact for status signaling, allowing direct interfacing with PLCs or control relays. The soft starter does not include a fieldbus interface as standard; for network integration (e.g., PROFINET or EtherNet/IP), an external gateway or connection module may be required. Always confirm cable and gateway compatibility with the supplier before commissioning. The device’s wide operating voltage range (200–460 V AC) and dual frequency (50/60 Hz) make it suitable for global applications. Whether used as a standalone unit or as part of a larger automation architecture, it delivers dependable performance.

FAQ

Q: What is the maximum operating temperature for the 3RW4427-1BC44?

A: The soft starter is rated for operation up to 60 °C ambient temperature, with current derating above 40 °C. At 50 °C, the rated current is 82 A, and at 60 °C it is 72 A.

Q: Can the 3RW4427-1BC44 be used in an inside-delta circuit?

A: Yes, it supports inside-delta connection, allowing a rated current of 161 A at 40 °C and a motor power of up to 90 kW at 400 V.

Q: What control voltage does the 3RW4427-1BC44 require?

A: The control supply voltage is 230 V AC at 50/60 Hz, with a tolerance of -15% to +10%.

Q: Does the 3RW4427-1BC44 include motor overload protection?

A: Yes, it features intrinsic device protection, motor overload protection, and thermistor motor protection evaluation.

Product Support & Availability

The Siemens 3RW4427-1BC44 is in stock and ready to ship from Mronexus. As your one-stop sourcing base for genuine industrial automation parts, we offer fast delivery and competitive pricing. Contact Mronexus for genuine industrial automation parts and experience reliable, value-for-money service.

Unmatched Customer Service

  • After Hours Shipping
  • Real Time Order Tracking
  • Flexible Delivery Options
  • Intact Technical Supports

Need a quote or technical support?

Send us your part numbers and we will get back within 24 hours.