52-0402-000 | Schneider Electric Modicon Quantum Tap Terminator 24V DC
HMI
- Brand: Schneider Electric
- Part Number:
52-0402-000 - Availability: Ask for quote
The Schneider Electric 52-0402-000 is a Modicon Quantum tap terminator that ensures reliable RS-485/Modbus communication by terminating unused drop locations. Operates on 24V DC with surge protection.
Product Details
When an Unused Drop Causes Network Failure
An automotive assembly line recently experienced intermittent communication faults on its Modicon Quantum control network. The root cause was traced to an unused tap on the RS-485 trunk—a classic source of signal reflections that corrupt data. The fix was simple yet critical: installing the Schneider Electric 52-0402-000 tap terminator. This compact device eliminates such issues by properly terminating unused drop locations, ensuring reliable Modbus communication.
In industrial automation, network integrity is paramount. The 52-0402-000 is a genuine Schneider Electric accessory designed specifically for the Modicon Quantum platform. It provides a reliable, value-for-money solution to maintain signal quality without costly downtime.

Key Features and Technical Specifications
- Operates on 24V DC input voltage with a current draw of only 40 mA.
- Supports digital RS-485/Modbus communication protocols.
- Wide operating temperature range: -20°C to 70°C.
- Storage temperature range: -40°C to 85°C.
- Handles cable lengths from 0 to 100 meters.
- Features surge protection to guard against voltage spikes.
- LED indicators provide clear status monitoring.
- DIN rail or panel mounting for easy installation.
- Reliable screw terminal or plug-in terminal blocks for wiring.
- Compact and lightweight: 5.0 g, dimensions 0.47 x 1.97 x 3.54 in.
The 52-0402-000 stands out for its robust surge protection and wide temperature tolerance, ensuring stable performance even in harsh industrial environments. Its low power consumption (40 mA) makes it energy-efficient and suitable for continuous operation.
Applications and Use Cases
The 52-0402-000 is essential in any Modicon Quantum network with unused drop locations. It is commonly used in manufacturing plants, process control systems, and infrastructure projects where reliable RS-485 communication is critical. For instance, in a water treatment facility, the tap terminator ensures that spare taps on the network do not introduce noise, maintaining uninterrupted data flow to SCADA systems. Similarly, in a packaging line, it prevents communication errors that could halt production. Its wide temperature range makes it suitable for both indoor control cabinets and outdoor enclosures.

Installation and Setup
Installing the 52-0402-000 is straightforward. Mount it on a DIN rail or panel using the provided hardware. Connect the device to the unused drop location using the screw terminal or plug-in terminal blocks, ensuring proper polarity. The LED indicators will confirm power and status. For detailed wiring diagrams, refer to the official Schneider Electric documentation.
Maintenance and Reliability
The 52-0402-000 requires minimal maintenance. Periodically inspect connections for tightness and check the LED indicators for any fault signals. The surge protection feature enhances longevity by safeguarding against voltage spikes. With its wide operating temperature range, it performs reliably in diverse environmental conditions, reducing the need for frequent replacements and lowering total cost of ownership.
Compatibility and Integration
Designed for the Modicon Quantum series, the 52-0402-000 integrates seamlessly with existing RS-485/Modbus networks. It is compatible with standard 24V DC power supplies and DIN rail mounting systems. When integrating into a fieldbus network, ensure proper termination and follow Modbus guidelines. For complex installations, consult the supplier for cable and gateway recommendations.
Troubleshooting Common Issues
If communication errors occur, first verify that the tap terminator is correctly installed on the unused drop. Check LED indicators for power and status. Ensure the input voltage is within 24V DC and connections are secure. If issues persist, test the network with a known good terminator or refer to the official datasheet.
Frequently Asked Questions
Q: What is the purpose of the 52-0402-000 tap terminator?
A: The 52-0402-000 terminates unused drop locations on a Modicon Quantum RS-485/Modbus network, preventing signal reflections and ensuring reliable communication.
Q: What are the operating temperature limits of the 52-0402-000?
A: It operates from -20°C to 70°C and can be stored from -40°C to 85°C, suitable for most industrial environments.
Q: Does the 52-0402-000 support long cable runs?
A: Yes, it supports cable lengths from 0 to 100 meters, making it versatile for various network layouts.
Q: What input voltage does the 52-0402-000 require?
A: The tap terminator operates on 24V DC and draws 40 mA, compatible with standard Modicon Quantum power supplies.
Product Support and Availability
The Schneider Electric 52-0402-000 is in stock and ready to ship from Mronexus. As your one-stop sourcing base for industrial automation parts, we offer genuine parts at competitive prices with worldwide fast delivery. Contact Mronexus for genuine industrial automation parts.
Unmatched Customer Service
- After Hours Shipping
- Real Time Order Tracking
- Flexible Delivery Options