Skip to content
sales@mronexus.com Reply within 24 hours Worldwide shipping

5466-355 | Woodward Remote Chassis Transceiver for VME Systems

PLC

  • Brand: Woodward
  • Part Number: 5466-355
  • Availability: Ask for quote

The Woodward 5466-355 Remote Chassis Transceiver enables reliable data transfer between Main and Remote I/O Chassis in CPU 68040 systems via high-speed differential VME bus interface.

Product Details

Reliable VME Bus Extension for CPU 68040 Systems

In industrial automation, signal integrity across distributed I/O chassis is a persistent challenge. The Woodward 5466-355 Remote Chassis Transceiver addresses this by providing a robust parallel interface that operates seamlessly at VME transmission rates. Designed exclusively for CPU 68040 systems, this module ensures that control, data, and address information is exchanged between the Main and Remote I/O Chassis without degradation. Whether you are expanding an existing system or replacing a faulty transceiver, the 5466-355 delivers the reliability and performance expected from genuine Woodward components.

Figure 1: Front view of the Woodward 5466-355 industrial automation component showing its physical design and enclosure.

Key Features & Technical Specifications

  • Part Number: 5466-355
  • Manufacturer: Woodward
  • Product Type: Remote Chassis Transceiver
  • Compatibility: CPU 68040 systems only
  • Interface: High-speed differential line drivers at VME transmission rate
  • Connector: 100-pin metal shell Micro-D (two per module)
  • Mounting: Slot 1 in Remote I/O Chassis
  • Termination: Available with or without termination resistors (for last vs. intermediate chassis)
  • Availability: In Stock
  • Country of Manufacture: United States (USA)

The use of high-speed differential line drivers is a standout feature, minimizing signal degradation and electromagnetic interference even over cable lengths of up to 3 meters. This ensures that your VME bus communication remains stable in electrically noisy industrial environments.

Installation & Configuration Best Practices

Proper installation is critical to avoid communication failures. The 5466-355 must be installed in Slot 1 of each Remote I/O Chassis. For all expansion chassis except the last in the chain, use the module without termination resistors. The final expansion chassis must use the module with termination resistors to prevent signal reflection and distortion. Additionally, each expansion chassis (except the last) requires a T-Module connected via 0.9 m cables, while connections from the Main Chassis and between T-Modules should use 3 m cables. The Main Transceiver module can be installed in any available slot in the Main Chassis, offering flexibility.

Figure 2: Technical layout and connection details for the Woodward 5466-355 industrial automation component.

Applications & Use Cases

The 5466-355 is essential in any CPU 68040-based system requiring remote I/O expansion. Typical applications include power generation control systems, where distributed I/O racks must communicate reliably with the main controller. In such setups, the transceiver ensures that real-time data from sensors and actuators is transmitted without latency or errors. Another common use is in older turbine control systems where maintaining original Woodward components is critical for compatibility and performance. By using the genuine 5466-355, engineers avoid the risks associated with aftermarket substitutes, such as signal mismatches and premature failures.

Maintenance & Troubleshooting

If the Remote XCVR module is not functioning, first check all cable connections. If the problem persists, replace the cables; if it still fails, replace the module. There are no LEDs or switches on the module, so diagnostics rely on system-level checks. Regular inspection of connectors for bent pins or corrosion is recommended, especially in harsh environments. Because the module operates at high speeds, any degradation in cable quality can lead to intermittent errors. Keeping spare cables and modules on hand minimizes downtime.

Compatibility & Integration

The 5466-355 is designed exclusively for Woodward CPU 68040 systems. It connects directly to the VME bus and uses 100-pin Micro-D connectors. No external gateways are required for VME communication, but ensure that cables are properly shielded to maintain signal integrity. For systems with multiple expansion chassis, correct termination is mandatory for reliable operation.

Frequently Asked Questions

Q: Can the 5466-355 be used with CPU 68040 systems from other manufacturers?

A: No, this module is specifically designed for Woodward CPU 68040 systems. Using it with other systems may cause compatibility issues.

Q: What is the difference between the module with and without termination resistors?

A: The module with termination resistors is used in the last expansion chassis to prevent signal reflection. Intermediate chassis use the version without termination resistors.

Q: How do I know if my Remote XCVR module is faulty?

A: Symptoms include communication errors or failure to recognize the remote chassis. First check cable connections, then replace cables, and finally replace the module if issues persist.

Q: Is the 5466-355 available for immediate shipping?

A: Yes, the 5466-355 is in stock and ready to ship. Contact Mronexus for genuine industrial automation parts and fast delivery.

Ordering Information

For genuine Woodward 5466-355 Remote Chassis Transceivers and other industrial automation components, trust Mronexus as your one-stop sourcing base. We offer reliable parts at competitive prices with worldwide shipping from stock. Contact Mronexus today to ensure your systems stay operational.

Unmatched Customer Service

  • After Hours Shipping
  • Real Time Order Tracking
  • Flexible Delivery Options
  • Intact Technical Supports

Need a quote or technical support?

Send us your part numbers and we will get back within 24 hours.