ATV610D55N4 | Schneider Electric 55kW Variable Speed Drive
VFD
- Brand: Schneider Electric
- Part Number:
ATV610D55N4 - Availability: Ask for quote
Schneider Electric ATV610D55N4 is a 55 kW variable speed drive with integrated C3 EMC filter, Modbus RTU, and plain text display. Ideal for pump and fan applications.
Product Details
Reliable Pump and Fan Control with the ATV610D55N4
In pump and fan applications, unplanned downtime often traces back to drive failures caused by overheating, electrical stress, or inadequate protection. The Schneider Electric ATV610D55N4 is engineered to address these pain points directly. As part of the Easy Altivar 610 series, this 55 kW (75 HP) normal-duty variable speed drive combines a robust design with integrated features that simplify installation and maintenance. With a 380…460 V three-phase supply, an integrated C3 EMC filter, and a plain text display terminal, it delivers reliable performance for demanding HVAC and water treatment systems.
At Mronexus, we supply genuine industrial automation parts at competitive prices, including this drive, with worldwide shipping and fast delivery from stock. Whether you need a single replacement or a complete bill of materials, our team can help you source the right components quickly.

Key Technical Specifications
- Operating temperature: -15…+45 °C without derating; up to +60 °C with power derating.
- Input voltage: 380…460 V AC, 50/60 Hz, three-phase.
- Power supply: 55 kW (75 HP) normal duty; 45 kW (60 HP) heavy duty.
- Communication protocol: Modbus RTU via two RJ45 ports; optional PROFIBUS DP V1 module.
- Maximum input current: 111.5 A at 380 V, 99.7 A at 460 V (normal duty).
- Maximum continuous output current: 120 A (normal duty); 132 A transient for 60 s.
- Integrated EMC filter: Category C3, reducing harmonic distortion.
- Protection rating: IP20 (IP40 on top).
- Dimensions (H×W×D): 762 × 290 × 323 mm; weight 53 kg.
The integrated DC choke significantly reduces input current harmonics, and an optional passive filter (VW3A460xx) can achieve THDi < 10%. This is particularly valuable in installations where power quality is a concern.
Comparison with Similar Variable Speed Drives
When selecting a drive for pump and fan applications, engineers often compare the ATV610 series with other options such as the ABB ACH580 or Danfoss VLT AQUA. The table below highlights key differentiators based on published data.
- Integrated EMC filter: ATV610D55N4 includes C3 filter as standard; many competitors offer it as an option.
- Communication: Built-in Modbus RTU with two RJ45 ports; PROFIBUS DP optional via slot. Competitors may require additional modules for serial communication.
- Operating temperature: -15…+45 °C without derating; up to 60 °C with derating. Comparable to industry standards.
- Overload capability: Normal duty 110% for 60 s or 120% for 20 s; heavy duty 150% for 60 s. Suitable for variable-torque loads.
- I/O flexibility: 3 analog inputs, 6 digital inputs, 2 analog outputs, 3 relay outputs, plus expansion slot for extended I/O or relay modules.
While exact specifications vary by model, the ATV610D55N4 offers a balanced feature set that reduces external component count and simplifies panel design.

Applications and Use Cases
The ATV610D55N4 excels in variable-torque applications such as centrifugal pumps and fans. Its quadratic U/f control (UFQ) optimizes energy consumption by matching motor output to load demand. In water treatment plants, the drive ensures smooth pressure control and reduces water hammer. For HVAC systems, it provides precise airflow management while minimizing noise and vibration. The conformal-coated electronic cards and 3C3/3S3 environmental class make it suitable for harsh industrial atmospheres. Additionally, the drive supports open-loop synchronous motor control (SYNU) and reluctance motor control (SRVC), offering flexibility for modern motor technologies.
Installation and Setup
Mount the drive vertically ±10° to ensure proper cooling. Maintain clearances of at least 100 mm at the top and bottom, and 10 mm at the front. Power terminal tightening torque is 25 N·m for frame size 5. The integrated plain text display terminal VW3A1113 simplifies parameter setting and diagnostics. For network integration, connect Modbus RTU using the RJ45 ports; for PROFIBUS DP, install the VW3A3607 module in Slot A. Always verify that the relay output supply meets Overvoltage Category II (OVC II); otherwise, use an isolation transformer.
Maintenance and Reliability
Regular maintenance extends drive life and prevents unexpected failures. Inspect the cooling fan periodically; it is field-replaceable in under 5 minutes without special tools. Check for dust accumulation on heatsinks and clean as needed. Verify terminal tightness annually. The conformal coating protects against corrosive gases and humidity, but ensure the enclosure meets the required IP rating. Operating within the specified temperature range avoids thermal stress. By preventing overheating and electrical faults, the ATV610D55N4 helps reduce downtime and maintenance costs, delivering a strong return on investment.
Compatibility and Integration
The drive integrates seamlessly with Schneider Electric PLCs and HMIs via Modbus RTU. For PROFIBUS DP networks, the optional VW3A3607 module provides Profidrive and CiA402 profiles. When connecting to other fieldbuses such as EtherNet/IP or PROFINET, an external gateway may be required. Always confirm cable and gateway compatibility with your supplier. The drive’s I/O can be expanded with the VW3A3203 extended I/O module or VW3A3204 extended relay module, providing additional flexibility for complex control schemes.
Frequently Asked Questions
Q: What is the operating temperature range of the ATV610D55N4?
A: The drive operates from -15 to +45 °C without derating. Above 45 °C up to 60 °C, power derating is required. Storage temperature ranges from -40 to +70 °C.
Q: Can the ATV610D55N4 be integrated into a PROFIBUS network?
A: Yes, by installing the optional PROFIBUS DP V1 module VW3A3607 in Slot A. The drive also has built-in Modbus RTU via two RJ45 ports. For other fieldbuses, an external gateway may be required.
Q: What is the maximum motor cable length without an output filter?
A: Up to 150 m shielded or 200 m unshielded. Above 50 m, an output dv/dt filter is recommended to protect the motor insulation and reduce EMI.
Q: Does the ATV610D55N4 include an EMC filter?
A: Yes, an integrated Category C3 EMC filter is standard. This makes the drive suitable for industrial environments. For more stringent requirements, additional filtering may be needed.
Product Support and Availability
The ATV610D55N4 is in stock and ready to ship from Mronexus. As your one-stop sourcing base for industrial automation parts, we offer genuine Schneider Electric drives at competitive prices. Contact Mronexus for genuine industrial automation parts and fast delivery worldwide.
Unmatched Customer Service
- After Hours Shipping
- Real Time Order Tracking
- Flexible Delivery Options
- Intact Technical Supports