BMEH586040 | Schneider Electric Redundant Processor Module 64MB
PLC
- Brand: Schneider Electric
- Part Number:
BMEH586040 - Availability: Ask for quote
Schneider Electric BMEH586040 redundant processor for Modicon M580 offers 64MB memory, 61 Ethernet devices, and 31 remote I/O racks. Ideal for high-availability process control.
Product Details
Redundant Processing Power for Critical Applications
In process control and manufacturing, unplanned downtime can cost thousands per hour. The Schneider Electric BMEH586040 redundant processor module for the Modicon M580 platform delivers high availability through hot standby redundancy, ensuring continuous operation even if one processor fails. With 64 MB of program and data memory, support for 61 Ethernet devices, and 31 remote I/O racks, this module is engineered for large-scale, mission-critical systems. As a genuine Schneider part, it offers reliable performance and long-term value, available from Mronexus at competitive prices.

Key Features & Technical Specifications
- Redundant processor module with hot standby link for automatic failover, minimizing downtime costs.
- 64 MB integrated RAM for program and data, plus 4 GB expandable flash storage for extensive logging.
- Supports 61 Ethernet devices and 31 remote I/O racks (X80 and Quantum), reducing hardware footprint.
- Operating temperature: 0…60 °C (32…140 °F), suitable for standard industrial cabinets.
- Input voltage: 24 V DC, current consumption 365 mA, powered via rack backplane.
- Communication: 1 Ethernet TCP/IP service port, 2 Ethernet TCP/IP device networks, 1 Ethernet HSBY port, USB mini B.
- Cybersecurity features: Achilles certified, embedded firewall, IPSec, TLS, audit trail, and password protection.
- MTBF of 650,000 hours, ensuring long service life and low maintenance costs.
- IP20 protection, CE, UL, CSA, RCM, EAC certifications for global deployment.
Each specification contributes to lower total cost of ownership: the high MTBF reduces spares consumption, the integrated Ethernet ports eliminate extra switches, and the cybersecurity suite avoids costly network breaches.
Applications & Use Cases
The BMEH586040 excels in process control applications where uptime is paramount, such as chemical plants, water treatment facilities, and power generation. In a redundant configuration, two processors operate in parallel; if the primary fails, the standby takes over seamlessly, preventing production losses. The module’s support for 31 remote I/O racks allows centralized control of large, distributed processes, reducing cabling and installation costs. Additionally, its cybersecurity features protect against unauthorized access, safeguarding intellectual property and operational data.

Installation and Setup
Install the BMEH586040 in a Modicon M580 rack with a compatible power supply and backplane. Ensure the rack is properly grounded and that the operating temperature remains within 0…60 °C. For redundant operation, configure two processors with identical firmware and connect them via the HSBY port using a dedicated cable. The module draws 365 mA at 24 V DC; verify the power supply has sufficient capacity for all modules. Use the Ethernet service port for programming and the device networks for I/O and distributed equipment. Refer to Schneider Electric’s installation manual for detailed wiring and configuration.
Compatibility and Integration
The BMEH586040 integrates seamlessly with Modicon M580 racks and supports X80 and Quantum I/O. It communicates over Ethernet TCP/IP, Modbus TCP, and EtherNet/IP, and can be extended with communication modules for AS-Interface, serial, and HART. Integration Note: When connecting to fieldbus networks such as PROFINET or DeviceNet, an external gateway or connection module may be required. Confirm cable and gateway compatibility with your supplier to avoid integration delays and extra costs.
Maintenance and Reliability
With a MTBF of 650,000 hours, the BMEH586040 is designed for long-term reliability. Perform regular visual inspections of status LEDs and ensure cabinet filters are clean to maintain airflow. In redundant setups, periodically test failover functionality to confirm the standby processor is ready. The module’s cybersecurity features require firmware updates; schedule these during planned downtime to avoid production impact. By preventing unexpected failures, the BMEH586040 reduces costly downtime and extends the lifecycle of your control system.
FAQ
Q: What is the operating temperature range of the BMEH586040?
A: The module operates from 0…60 °C (32…140 °F), suitable for standard industrial environments. Ensure proper cabinet ventilation to avoid overheating, which can reduce MTBF and increase failure risk.
Q: How many Ethernet devices can the BMEH586040 support?
A: It supports up to 61 Ethernet devices (64 distributed equipment) via two Ethernet TCP/IP device networks, enabling extensive I/O and drive integration without additional communication modules.
Q: What communication protocols are available on this processor?
A: The BMEH586040 provides Ethernet TCP/IP, HSBY (hot standby) for redundancy, USB mini B, and supports Modbus TCP, EtherNet/IP, and other protocols via communication modules. Refer to official Schneider documentation for detailed protocol support.
Q: What is the power consumption of the BMEH586040?
A: It draws 365 mA at 24 V DC from the rack power supply. Ensure the power supply can handle the total load of all modules in the rack, especially in redundant configurations.
Product Support & Availability
The Schneider Electric BMEH586040 is in stock and ready to ship from Mronexus. As your one-stop sourcing base for industrial automation parts, we offer genuine products at competitive prices with worldwide fast delivery. Contact Mronexus for genuine industrial automation parts and ensure your critical systems stay operational.
Unmatched Customer Service
- After Hours Shipping
- Real Time Order Tracking
- Flexible Delivery Options
- Intact Technical Supports