The SICK DL100-12AA2102 is a long-range laser distance sensor with 130 m measuring range, PROFIBUS DP interface, and ±2 mm accuracy for demanding industrial positioning tasks.
Product Details
Long-Range Laser Positioning for Demanding Automation
When automated storage and retrieval systems (ASRS) or overhead monorails need reliable position feedback over distances exceeding 100 metres, conventional sensors often fall short. The SICK DL100-12AA2102 laser distance sensor, part of the Dx100 series, addresses this challenge with a phase-shift optical time-of-flight measurement principle that delivers accurate, non-contact distance readings up to 130 metres on Diamond Grade reflective tape. Designed for industrial environments, this sensor combines a visible red laser (Class 2) with a robust aluminium die-cast housing rated IP65, making it suitable for dusty or washdown-prone areas.

Key Features and Technical Specifications
- Measurement range: 0.15 m to 130 m on Diamond Grade reflective tape.
- Light source: visible red laser diode, 658 nm, Class 2 (<1 mW).
- Measurement accuracy: typically ±2 mm to ±3 mm.
- Repeatability: 0.5 mm to 1 mm (typical 0.5 mm at 1 σ).
- Maximum tracking velocity: 15 m/s; acceleration: 15 m/s².
- Output time: ≥1 ms (internal cycle 1 ms, fieldbus dependent).
- Communication: PROFIBUS DP (EN 50170, up to 12 Mbit/s).
- Digital outputs: 2x push-pull (PNP/NPN, configurable), ≤100 mA.
- Supply voltage: DC 18 V to 30 V, reverse-polarity protected.
- Power consumption: typically 8 W to 10 W.
- Operating temperature: -20 °C to +55 °C; storage: -40 °C to +75 °C.
- Enclosure rating: IP65 (EN 60529); housing: aluminium die-cast with PMMA window.
- Weight: approximately 800 g.
The high tracking velocity and acceleration capabilities make this sensor particularly suited for dynamic applications such as automated storage and retrieval systems, where fast movement and precise positioning are critical. The integrated LC display simplifies setup and diagnostics, while continuous condition monitoring tracks signal level attenuation, laser diode aging, and temperature, enabling predictive maintenance.
Applications and Use Cases
In automated warehouses, the DL100-12AA2102 provides reliable position feedback for stacker cranes and shuttle systems, even over long travel distances. Its PROFIBUS DP interface integrates seamlessly with PLC-based control systems, allowing real-time data exchange for precise motion control. The sensor’s ability to handle high acceleration and velocity makes it ideal for high-speed sorting and overhead monorail systems. Additionally, the IP65 rating and wide temperature range ensure dependable operation in harsh industrial environments, from cold storage to dusty production floors.

Installation and Integration
The DL100-12AA2102 features an optical 3-axis alignment bracket (available separately) that simplifies precise alignment with reflective tape. Electrical connection is straightforward: power via a 4-pin M12 male connector, and PROFIBUS In/Out via two 5-pin M12 female connectors (B-coded, SPEEDCON™). When integrating into a PROFIBUS network, ensure proper termination and cable specifications; for other fieldbus systems, an external gateway may be required. The integrated display and menu navigation assist with parameter setting and diagnostics during commissioning.
Maintenance and Reliability
To maintain optimal performance, regularly inspect the optical window for dust or debris and clean with a soft, lint-free cloth. The sensor’s continuous condition monitoring provides early warning of signal degradation, allowing maintenance to be scheduled before failures occur. With no moving parts, the DL100-12AA2102 offers long service life and low maintenance costs, contributing to reduced downtime and total cost of ownership. Store and operate within specified temperature limits to avoid condensation and ensure reliable operation.
Frequently Asked Questions
Q: What is the maximum measuring range of the DL100-12AA2102?
A: The sensor measures up to 130 m when using Diamond Grade reflective tape, with a minimum range of 0.15 m.
Q: Which communication protocol does the DL100-12AA2102 support?
A: It uses PROFIBUS DP (EN 50170) with data rates up to 12 Mbit/s, and provides two additional configurable push-pull digital outputs.
Q: What is the operating temperature range of this sensor?
A: The DL100-12AA2102 operates reliably from -20 °C to +55 °C and can be stored from -40 °C to +75 °C.
Q: How accurate is the DL100-12AA2102?
A: Typical measurement accuracy is ±2 mm to ±3 mm, with repeatability of 0.5 mm to 1 mm, depending on conditions.
Product Support and Availability
The SICK DL100-12AA2102 is in stock and ready to ship from Mronexus. As your one-stop sourcing base for genuine industrial automation parts, we offer competitive prices and fast worldwide delivery. Contact Mronexus for genuine industrial automation parts and expert support.
Unmatched Customer Service
- After Hours Shipping
- Real Time Order Tracking
- Flexible Delivery Options
- Intact Technical Supports