Skip to content
sales@mronexus.com +86 180 3000 5825 Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China Reply within 24 hours Worldwide shipping

E82CV552K4C | Lenze 8200 vector 5.5kW Cold-Plate Inverter

PLC

  • Brand: Lenze
  • Part Number: E82CV552K4C
  • Availability: Ask for quote

Lenze E82CV552K4C 8200 vector frequency inverter, 5.5 kW, cold-plate design. Reliable V/f and sensorless vector control for demanding industrial applications.

Product Details

Lenze E82CV552K4C: Cold-Plate Drive Reliability for Cabinet-Cooled Systems

When a standard heatsink inverter cannot fit or when heat must be removed outside the enclosure, the Lenze E82CV552K4C offers a practical answer. Part of the proven 8200 vector series, this 5.5 kW frequency inverter uses cold-plate technology: the conventional heatsink is replaced by a bare metal cooling plate that connects to a customer-supplied cooler. The result is a reliable, compact drive that keeps cabinet temperatures under control while delivering full motor performance. As a genuine Lenze part available from Mronexus, it represents a value-for-money solution for engineers maintaining or upgrading existing 8200 vector installations.

Figure 1: Front view of the Lenze E82CV552K4C industrial automation component showing its physical design and enclosure.

Key Technical Specifications

  • Rated motor power: 5.5 kW typical for 4-pole three-phase asynchronous motors.
  • Supply voltage: 3/PE AC 320 V –0% to 550 V +0%, 45–65 Hz.
  • Rated output current: 13.0 A nominal at 8 kHz switching frequency.
  • Max. output current: 19.5 A for 60 s (1 min overload at Imax / 2 min at 75% Ir).
  • Operating temperature: -10 to +55 °C, derated by 2.5%/°C above +40 °C.
  • Storage temperature: -25 to +60 °C.
  • Relative humidity: average 85% RH, non-condensing (climatic class 3K3 per EN 50178).
  • Protection rating: IP20.
  • Control modes: V/f characteristic (linear/quadratic) and sensorless vector control; output frequency -650 to +650 Hz.
  • Integrated brake transistor: enables dynamic braking without external hardware.
  • Built-in I/O: 1 analog input, 1 analog output, 4 digital inputs, 1 digital output, 1 relay output (changeover, 250 V AC / 3 A).
  • Cold-plate thermal data: dissipated power loss 190 W; thermal resistance Rth ≤ 0.23 K/W; max. permissible cooling-plate temperature 75 °C.

The cold-plate design is the standout feature here: by removing heat directly through the mounting plate, it eliminates the need for a bulky heatsink and allows the drive to operate reliably in sealed or densely packed cabinets. The 190 W power loss figure and low thermal resistance ensure that, with an adequately sized external cooler, the inverter maintains full 5.5 kW output even at elevated ambient temperatures.

Communication and Integration

The E82CV552K4C provides an X3 control terminal strip for analog and digital I/O as standard. It does not include a built-in fieldbus protocol; instead, a FIF slot accepts plug-in function modules from the E82ZAF* family. This modular approach lets you add PROFIBUS, CANopen, or other networks as required. When integrating into a fieldbus network, note that wiring may require an external gateway or connection module; confirm cable and gateway compatibility with your supplier. For most applications, the built-in I/O and relay output are sufficient for standalone control, while the expansion slot future-proofs the drive for networked architectures.

Figure 2: Technical layout and connection details for the Lenze E82CV552K4C industrial automation component.

Reliability and Maintenance

Designed for industrial environments, the E82CV552K4C operates reliably from -10 to +55 °C, with derating above +40 °C. The IP20 rating means it should be installed in a protective enclosure, which is typical for cabinet-mounted drives. Key wear points are the cooling plate interface and the external cooler. We recommend inspecting the thermal contact between the plate and cooler every 6–12 months, ensuring the cooling medium flows correctly and that the plate temperature does not exceed 75 °C. Because the drive relies on an external cooler, maintaining the cooler’s performance directly extends the inverter’s service life. This proactive maintenance, combined with the drive’s robust design, delivers reliable, long-term operation and reduces unplanned downtime.

Applications and Use Cases

The cold-plate design makes this inverter particularly suited to applications where heat removal from the cabinet is critical. Common use cases include machine tools, packaging equipment, and material handling systems installed in compact enclosures. For example, in a retrofitted production line where cabinet space is limited, the E82CV552K4C can be mounted directly onto a liquid-cooled plate, keeping internal temperatures stable and avoiding the need for additional air conditioning. Its 5.5 kW rating and 19.5 A overload capability handle demanding starts and intermittent loads reliably. Engineers upgrading from older 8200 vector drives will appreciate the familiar parameter structure and the availability of a genuine Lenze replacement.

Lifecycle and Sourcing

Lenze lists the 8200 vector series as a previous product, but the cold-plate special design remains available on request. For new designs, Lenze offers a migration path to the i950 series, which can emulate 8200 vector behaviour via the i950 PROFIBUS module and L_ICIP library. However, there is no drop-in same-order-code replacement, so maintaining existing E82CV552K4C units is often the most cost-effective strategy. Mronexus supplies genuine industrial automation parts at competitive prices, including this cold-plate inverter, with worldwide shipping and fast delivery from stock. As your one-stop sourcing base for PLC, HMI, servo, sensor, and circuit breaker needs, we help you keep production running without delays.

Frequently Asked Questions

Q: What is the operating temperature range of the E82CV552K4C?

A: The inverter operates from -10 to +55 °C, with a derating of 2.5% per °C above +40 °C. Ensure the cooling plate temperature does not exceed 75 °C.

Q: Does this model include a built-in fieldbus protocol?

A: No, fieldbus communication requires a plug-in function module from the E82ZAF* family. The standard X3 terminal strip provides analog and digital I/O.

Q: Can I replace an existing 8200 vector standard inverter with this cold-plate version?

A: The E82CV552K4C is a special cold-plate design, not a drop-in replacement for standard heatsink models. Review mounting and cooling requirements; for new designs, Lenze offers migration to the i950 series.

Q: What is the supply voltage range for this drive?

A: It accepts 3/PE AC 320 V –0% to 550 V +0%, 45–65 Hz, making it suitable for a wide range of industrial power systems.

For genuine industrial automation parts and expert support, contact Mronexus today.

Unmatched Customer Service

  • After Hours Shipping
  • Real Time Order Tracking
  • Flexible Delivery Options
  • Intact Technical Supports

Need a quote or technical support?