Skip to content
sales@mronexus.com +86 180 3000 5825 Room 7A, No. 59 Hubin North Road, Siming District Xiamen City China Reply within 24 hours Worldwide shipping

EMERSON 191736-01 | Emerson Rotary Encoder 5VDC 10-Pin

PLC

  • Brand: Emerson
  • Part Number: EMERSON 191736-01
  • Availability: Ask for quote

The Emerson 191736-01 is a flange-mount rotary encoder for valve position feedback. It operates on 5 VDC, features a 10-pin terminal block, and offers IP66 protection for reliable performance in harsh industrial environments.

Product Details

Ensuring Reliable Valve Position Feedback

In valve-driven processes, inaccurate position feedback can lead to misoperation, safety hazards, and costly downtime. The EMERSON 191736-01 rotary encoder addresses this by providing precise end-of-travel signaling through mechanical or inductive contacts. Designed for flange mounting, this encoder integrates seamlessly with valve signaling boxes, ensuring that open and closed positions are reliably detected. With a 5 VDC input and a 10-pin terminal block, it offers straightforward installation and robust performance in demanding industrial environments.

Figure 1: Front view of the Emerson EMERSON 191736-01 industrial automation component showing its physical design and enclosure.

Key Features & Technical Specifications

  • Operates on 5 VDC for low-power signal generation.
  • Mechanical contacts rated 24 V AC/DC, breaking capacity 0.5 A (max 1 A).
  • Inductive contacts (PNP/NPN) accept 10 to 30 V DC, 100 mA.
  • Ambient temperature: -20°C to +80°C (mechanical), -20°C to +70°C (inductive).
  • IP66 protection for dust and water resistance.
  • 10-pin terminal block accepts 0.14–2.5 mm² stranded wire.
  • SIL2 capable (IEC 61508:2010) for safety-critical applications.
  • Flange mount design with glass-fiber reinforced PA body.

The encoder’s cam-operated contacts provide a distinct electrical signal at end-of-travel, eliminating ambiguity in valve status. The IP66 rating ensures reliable operation even in washdown or outdoor environments.

Applications & Use Cases

The EMERSON 191736-01 is ideal for valve position monitoring in chemical processing, water treatment, and oil & gas industries. In a typical application, the encoder is mounted on a valve actuator to signal open/closed status to a PLC. Its SIL2 capability makes it suitable for safety instrumented systems, while the wide temperature range supports use in extreme climates. The flange mount and 10-pin connector simplify retrofit installations.

Figure 2: Technical layout and connection details for the Emerson EMERSON 191736-01 industrial automation component.

Installation & Setup

Mount the encoder to the valve signaling box using the flange, ensuring the plunger engages the valve stem cams. Connect wiring to the 10-pin terminal block, observing polarity for inductive contacts. Use the M16x1.5 cable gland for cable entry (4–8 mm diameter). Verify contact operation by manually cycling the valve and checking signal continuity. For inductive contacts, ensure supply voltage is within 10–30 V DC.

Maintenance & Reliability

Regular inspection of the cams and contacts is recommended every 6 months or after 100,000 cycles. Check for wear on the plunger and contacts, and clean any debris from the enclosure. The IP66 rating protects against ingress, but ensure cable gland seals are intact. Operating within specified temperature ranges prevents premature failure. With proper maintenance, the encoder delivers long service life, reducing downtime and replacement costs.

Compatibility & Integration

The EMERSON 191736-01 integrates with PLCs and control systems via discrete input cards. When used in fieldbus networks such as PROFINET or EtherNet/IP, an external gateway or connection module may be required to convert the contact signals. Confirm cable and gateway compatibility with the supplier. The encoder is compatible with most valve actuators that accept a flange mount and 10-pin interface.

Frequently Asked Questions

Q: What is the operating temperature range for the EMERSON 191736-01?

A: Mechanical contacts are rated for -20°C to +80°C, while inductive contacts (PNP/NPN) are rated for -20°C to +70°C.

Q: What input voltage does the EMERSON 191736-01 require?

A: Mechanical contacts accept 24 V AC/DC, and inductive contacts require 10 to 30 V DC. The encoder itself operates on 5 VDC.

Q: What communication protocol does this encoder use?

A: The EMERSON 191736-01 provides electrical signals via mechanical or inductive contacts; it does not use a digital communication protocol. For network integration, an external gateway may be required.

Q: Is the EMERSON 191736-01 SIL2 capable?

A: Yes, it is SIL2 capable according to IEC 61508:2010, making it suitable for safety-related applications.

Product Support & Availability

The EMERSON 191736-01 is in stock and ready to ship from Mronexus. As your one-stop sourcing base for genuine industrial automation parts, we offer fast delivery and competitive prices. Contact Mronexus for genuine industrial automation parts and expert support.

Unmatched Customer Service

  • After Hours Shipping
  • Real Time Order Tracking
  • Flexible Delivery Options
  • Intact Technical Supports

Latest News

Insights, product guides and industry updates from our team.

Need a quote or technical support?

Send us your part numbers and we will get back within 24 hours.