FX1S-14MT-001 | Mitsubishi PLC 14-Point Relay | Fast Ship
PLC
- Brand: Mitsubishi
- Part Number:
FX1S-14MT-001 - Availability: Ask for quote
Mitsubishi FX1S-14MT-001 PLC: 14 I/O (8 in, 6 relay out), AC100-240V supply, DC24V input, 16K steps, EEPROM. Reliable control for small machines. Genuine parts, fast delivery from Mronexus.
Product Details
Product Introduction
For maintenance engineers, the Mitsubishi FX1S-14MT-001 PLC is a reliable choice for small-scale control tasks. As part of the FX1S series, it packs 14 I/O points (8 inputs, 6 relay outputs) into a compact 60×75×90 mm housing. Operating on AC100-240V, it handles input signals up to DC24V and offers 16,000 steps of program memory with EEPROM backup. Whether you’re upgrading an existing system or building a new one, this PLC delivers the genuine reliability you expect from Mitsubishi. At Mronexus, we supply genuine industrial automation parts at competitive prices, ensuring your operations stay up and running.

Key Features & Technical Specifications
- I/O Configuration: 8 input points and 6 relay output points (14 total) for versatile control.
- Power Supply: AC100-240V wide-range input for global compatibility.
- Input Signal: DC24V input voltage, compatible with standard industrial sensors.
- Output Type: Relay output, ideal for switching inductive loads directly.
- Program Memory: 16,000 steps, EEPROM (no battery required).
- Dimensions: 60 × 75 × 90 mm, compact footprint for tight spaces.
- Temperature Input: Supports platinum temperature resistance 3-wire (4 points) with 0.2~0.3°C resolution.
- Sensor Current: 1mA for stable temperature readings.
- Communication: Serial communication capability for data transmission.
The relay output type stands out for maintenance engineers—it allows direct switching of solenoids, contactors, and other inductive loads without additional interface relays, simplifying panel design and reducing component count.
Applications & Use Cases
The FX1S-14MT-001 excels in small mechanical equipment where space and cost are critical. Its relay outputs make it suitable for controlling motor starters, valves, and heating elements directly. In packaging machines, it can manage indexing and sealing operations with precise timing. For temperature-critical processes, the built-in platinum resistance input (3-wire, 4 points) enables direct connection of PT100 sensors, eliminating separate temperature controllers. Maintenance engineers appreciate the relay output’s robustness in high-cycle applications, as it can handle inrush currents that would damage transistor outputs. From conveyor control to small assembly stations, this PLC provides reliable, repeatable performance.

Installation & Setup
Mount the FX1S-14MT-001 on a standard DIN rail or panel using the provided mounting holes. Ensure the power supply is within AC100-240V and properly grounded. For input wiring, use shielded cables for noise immunity, especially when routing near variable frequency drives. The relay output terminals accept wire sizes up to 2.5 mm². Maintain at least 50 mm clearance above and below the unit for adequate ventilation. The screw terminal blocks are designed for quick connection and maintenance. Before power-up, verify that input signals do not exceed DC24V to prevent damage. For temperature sensor connections, use 3-wire PT100 sensors and configure the input type in the programming software.
Maintenance & Reliability
Regular maintenance is key to maximizing the FX1S-14MT-001’s service life. Inspect relay contacts every 6 months for wear, especially in high-cycle applications—replace the PLC if contact resistance increases significantly. Clean the ventilation slots annually to prevent overheating. Operating temperature should be kept within 0-55°C; avoid mounting near heat sources. The EEPROM memory eliminates battery replacement, reducing maintenance downtime. For reliable performance, use genuine Mitsubishi parts and follow the recommended inspection schedule. Mronexus offers fast delivery from stock, ensuring you get replacement units quickly when needed.
Compatibility & Integration
The FX1S-14MT-001 integrates seamlessly with Mitsubishi’s FX family. It is compatible with FX1N, FX2N, FX3U, and FX2NC series PLCs (via FX2NC-CNV-IF) and FX3UC (via FX2NC-CNV-IF or FX3UC-1PS-5V). For serial communication, it supports data transmission through standard RS-422/485 interfaces, allowing connection to HMIs and upper-level systems. When integrating into a fieldbus network such as PROFINET or EtherNet/IP, an external gateway or communication module may be required. Confirm cable and gateway compatibility with your supplier to ensure smooth integration.
FAQ
Q: What is the power supply requirement for the FX1S-14MT-001?
A: The PLC operates on AC100-240V, 50/60Hz. Ensure a stable power supply within this range to avoid malfunctions.
Q: Can I connect PT100 sensors directly to this PLC?
A: Yes, the FX1S-14MT-001 supports 3-wire platinum temperature resistance inputs (4 points) with a resolution of 0.2~0.3°C. Configure the input type in your programming software.
Q: What is the output type and its typical application?
A: It features relay outputs, suitable for directly switching inductive loads like solenoids and contactors. The relay contacts are rated for typical industrial loads.
Q: Does the PLC require a battery for memory backup?
A: No, it uses EEPROM memory, eliminating the need for battery maintenance.
Q: How many I/O points does the FX1S-14MT-001 have?
A: It provides 14 total points: 8 inputs and 6 relay outputs.
Product Support & Availability
The Mitsubishi FX1S-14MT-001 is in stock and ready to ship from Mronexus. As your one-stop sourcing base for industrial automation parts, we ensure fast delivery and genuine products. Contact Mronexus for genuine industrial automation parts and experience reliable, value-for-money service.
Unmatched Customer Service
- After Hours Shipping
- Real Time Order Tracking
- Flexible Delivery Options
- Intact Technical Supports




