IC200ALG266 | GE VersaMax 15-Ch Analog Input Module
PLC
- Brand: GE
- Part Number:
IC200ALG266 - Availability: Ask for quote
The IC200ALG266 is a GE VersaMax 15-channel analog input module with 15-bit resolution and 7.5 ms update, delivering reliable performance for distributed I/O systems.
Product Details
IC200ALG266: Cost-Effective Analog Input for VersaMax Systems
In distributed I/O architectures, every millivolt and every millisecond counts—especially when unplanned downtime can cost thousands per hour. The IC200ALG266 from GE (formerly GE Fanuc, now under Emerson Automation) is a 15-point analog voltage input module designed to deliver precise, reliable measurements without the overhead of external power supplies or complex wiring. With 15 single-ended channels accepting -10 to +10 VDC signals, this module integrates seamlessly into VersaMax systems, helping engineers reduce total cost of ownership through high channel density and robust diagnostics.

Key Technical Specifications
- 15 single-ended input channels in a single group, reducing per-point cost in compact installations.
- 15-bit resolution (0.3125 mV per count) enables accurate monitoring of low-level signals.
- Input signal range: -10 to +10 VDC accommodates a wide variety of industrial sensors.
- Update rate: 7.5 ms maximum for all channels, ensuring timely data for control loops.
- Accuracy: ±0.3% typical, ±1% maximum at 25°C, supporting reliable process control.
- Backplane current: 100 mA maximum at 5V (150 mA max total), minimizing power budget impact.
- Isolation: 250 VAC continuous; 1500 VAC for 1 minute protects against voltage transients.
- Filter response: 32 Hz ±20% with per-channel update, reducing noise without external filters.
- Operating temperature: 0 to 60°C (accuracy derated above 25°C), suitable for typical industrial environments.
- Diagnostics: Loss of internal power and A/D conversion error reported to CPU for fast fault detection.
Cost-Saving Performance in Demanding Applications
The IC200ALG266 shines in applications where accurate analog measurement directly impacts operational efficiency. In process monitoring, 15-bit resolution allows detection of small signal changes, enabling tighter control and reduced waste. For distributed I/O systems, the module’s single-slot width and backplane-powered design eliminate external power supplies and wiring, cutting installation time and material costs. In energy management, the 7.5 ms update rate ensures real-time data for load balancing, helping avoid peak demand charges. Even in legacy system upgrades, the IC200ALG266 offers a cost-effective drop-in replacement for existing VersaMax installations, minimizing downtime and requalification effort.

Installation and Setup Best Practices
Installing the IC200ALG266 is straightforward: it mounts in any VersaMax I/O rack and draws power from the backplane, so no external supply is needed. Use shielded twisted-pair cable for analog signals and route away from high-voltage lines to minimize noise. The module’s software-configurable fault response (default or last state) should be set according to your fail-safe strategy. For systems using fieldbus networks such as PROFINET or EtherNet/IP, note that direct connection may require an external gateway or communication module; confirm cable and gateway compatibility with your supplier before commissioning.
Maintenance and Reliability
The IC200ALG266 is designed for long service life with minimal maintenance. The OK LED provides at-a-glance status, while built-in diagnostics report channel faults to the CPU, enabling predictive maintenance. In high-temperature environments (above 25°C), accuracy degrades to ±1% maximum at 60°C, so ensure adequate panel ventilation. Periodic inspection of wiring connections and cleaning of dust from the module are recommended. By catching faults early, you avoid costly unplanned downtime and extend the module’s useful life.
Frequently Asked Questions
Q: What is the input voltage range of the IC200ALG266?
A: The module accepts -10 to +10 VDC single-ended inputs, with a resolution of 0.3125 mV per count (15 bits).
Q: Does the IC200ALG266 require an external power supply?
A: No, it is powered entirely from the backplane (5 VDC, 100 mA maximum). No external supply is needed for channel activation.
Q: How does the module handle fault conditions?
A: Each channel detects A/D conversion errors and loss of internal power. Faults are reported to the CPU, and the module can be configured to hold last state or go to default on CPU stop or module error.
Q: What is the operating temperature range and accuracy?
A: The module operates from 0 to 60°C. Accuracy is ±0.3% typical at 25°C, degrading to ±1% maximum at 60°C.
Q: Can I use the IC200ALG266 with PROFINET or EtherNet/IP?
A: The module itself does not have a fieldbus interface; it connects to a VersaMax CPU or bus controller. For fieldbus integration, an external gateway may be required. Consult your supplier for compatibility.
Ordering and Support
Mronexus supplies genuine industrial automation parts, including the IC200ALG266, at competitive prices. This module is in stock and ready to ship, ensuring fast delivery to minimize your downtime. As your one-stop sourcing base for PLC, HMI, servo, sensor, and circuit breaker needs, we help you streamline procurement. Contact Mronexus for genuine industrial automation parts and experience reliable, value-for-money service.