MTL3045 | MTL Isolator 4-20mA 800Ω Load
PLC
- Brand: MTL
- Part Number:
MTL3045 - Availability: Ask for quote
The MTL3045 is a reliable single-channel isolator that drives I/P converters and actuators in hazardous areas, supporting up to 800Ω loads with high accuracy and low drift.
Product Details
Reliable Signal Isolation for Hazardous-Area Actuators
When a control signal must reach an I/P converter or position actuator inside a hazardous area, signal integrity and safety are non-negotiable. The MTL3045 from MTL is a single-channel, fully floating isolator designed to pass 4/20mA or 0/20mA signals from a safe-area controller to loads up to 800Ω in Zone 0, IIC, T4–6 or Div 1, Group A locations. From a maintenance engineer’s perspective, this module stands out for its robust output drive, low temperature drift, and straightforward serviceability—making it a dependable choice for critical loop control.

Key Features and Technical Specifications
- Number of channels: One, fully floating for complete galvanic isolation.
- Input resistance: ≤200Ω (4V drop at 20mA) minimises burden on the controller loop.
- Output drive: 16V at 20mA allows driving loads up to 800Ω, ideal for I/P converters and positioners.
- Transfer accuracy: Better than 20µA at 20°C ensures precise signal reproduction.
- Temperature drift: <1µA/°C maintains stability across wide ambient temperature swings.
- Ripple: <40µA peak-to-peak keeps noise low for sensitive actuators.
- Response time: Settles to within 10% of final value in typically 55ms.
- Power requirement: 65mA typical at 24V; 90mA maximum at 20 to 35V.
- Power dissipation: 1.5W typical at 24V with 20mA signal; 2.3W maximum at 35V.
- Replaceable fuse: 125mA, 5x20mm glass, semi-time-lag (M) to DIN 41571.
- Safety description: 28V, 300Ω, 93mA, Um = 250V rms or dc; FM entity parameters Voc = 28V, Isc = 93mA, Ca = 0.13µF, La = 4.0mH.
- Weight: 150g.
The high output capability of 16V at 20mA, combined with the low 4V input drop, makes the MTL3045 particularly suited for driving current-to-pressure converters that demand a substantial voltage margin. The excellent accuracy and low drift directly translate to reduced recalibration frequency and fewer nuisance trips.
Applications and Use Cases
In a typical process plant, the MTL3045 isolates and transmits a 4/20mA control signal from a DCS or PLC to an I/P converter mounted in a hazardous area. This is common in flow control loops where a valve positioner must receive a reliable signal despite long cable runs and noisy environments. The module’s 800Ω load capacity provides headroom for the I/P converter’s coil resistance and any additional cable resistance, ensuring the actuator receives the full commanded current. Additionally, when paired with the MTL3046B, the MTL3045 can transfer measurement or control signals through a hazardous area separating two safe areas—useful for interconnecting separate control rooms or marshalling cabinets. In all these scenarios, the maintenance engineer benefits from the module’s low drift, which reduces the need for periodic calibration and helps maintain loop performance over time.

Installation and Setup
The MTL3045 is designed for panel mounting in a safe area, with field wiring to the hazardous area passing through the isolator. For proper installation, ensure the module is mounted in a location that provides adequate ventilation to dissipate the typical 1.5W (maximum 2.3W) of heat. Connect the input terminals to the controller output, observing polarity, and connect the output terminals to the hazardous-area load. The replaceable 125mA fuse protects the output circuit; use only a fuse of the same type and rating. Verify that the safety description parameters (28V, 300Ω, 93mA) are compatible with the hazardous-area certification of the connected equipment. Always follow local wiring codes and the manufacturer’s datasheet for detailed terminal assignments and earthing requirements.
Maintenance and Reliability
From a maintenance perspective, the MTL3045 offers several features that simplify servicing. The replaceable fuse allows quick recovery from output short circuits without replacing the entire module. The low temperature drift of <1µA/°C means that calibration intervals can be extended in stable ambient conditions, reducing routine maintenance effort. Periodic inspection should include checking the fuse continuity, verifying output current with a calibrated meter, and ensuring that the module's ventilation paths are clear of dust and debris. Because the module is fully floating, there is no need for periodic isolation testing beyond standard loop checks. In environments with significant temperature variation, the drift specification provides confidence that the signal will remain within tolerance, minimising the risk of unplanned shutdowns. For long-term reliability, keep spare fuses on hand and avoid operating the module above 35V, which would increase power dissipation and internal heating.
Compatibility and Integration
The MTL3045 is compatible with standard 4/20mA and 0/20mA control systems and can be integrated into new or existing loops. It does not require any communication protocol; it is a pure analog isolator. When used in conjunction with the MTL3046B, it enables signal transfer between two safe areas through a hazardous area. For installations where the MTL3045 is part of a larger fieldbus segment, note that it does not directly interface with PROFINET, EtherNet/IP, or other fieldbus networks—those require separate gateways or connection modules. Always confirm cable and gateway compatibility with the supplier when integrating into a networked architecture.
Troubleshooting Common Issues
If the output signal is absent or low, first check the replaceable fuse; a blown fuse often indicates an output short circuit or overload. Verify that the input current from the controller is within the 0–20mA range and that the input resistance is not excessive. If the output current is unstable, inspect for loose terminal connections or excessive ripple on the input supply. High ambient temperature can cause the module to drift; ensure adequate ventilation and consider derating if the enclosure temperature exceeds 60°C. When driving an I/P converter, confirm that the total load resistance (including cable) does not exceed 800Ω. For persistent issues, refer to the official MTL documentation or contact Mronexus for genuine replacement parts.
Frequently Asked Questions
Q: What is the maximum load resistance the MTL3045 can drive?
A: The MTL3045 can drive loads up to 800Ω, thanks to its 16V output at 20mA. This provides ample headroom for I/P converters and position actuators.
Q: Can the MTL3045 be used in Zone 0 hazardous areas?
A: Yes, when suitably certified, the MTL3045 can be installed in Zone 0, IIC, T4–6 hazardous areas or Div 1, Group A locations. Always verify the safety description and entity parameters against your area classification.
Q: How often should the fuse be replaced?
A: The fuse is a replaceable 125mA glass type; replace it only when blown. Regular inspection is recommended, but no scheduled replacement interval is specified. Keep spare fuses (DIN 41571 sht.2, semi-time-lag) on hand for quick servicing.
Q: What is the temperature drift of the MTL3045?
A: The temperature drift is less than 1µA/°C, ensuring stable signal transmission across varying ambient temperatures.
Q: Does the MTL3045 require any special configuration?
A: No configuration is needed; it is a fixed-gain isolator. Simply wire the input and output according to the datasheet, and ensure the load and supply voltage are within specified limits.
Product Support and Availability
The MTL3045 is in stock and ready to ship from Mronexus. As your one-stop sourcing base for genuine industrial automation parts, we offer fast delivery and competitive prices on MTL isolators and related components. Contact Mronexus for genuine industrial automation parts and expert support.
Unmatched Customer Service
- After Hours Shipping
- Real Time Order Tracking
- Flexible Delivery Options
- Intact Technical Supports