The MTL3073 converts low-level DC signals from temperature sensors in hazardous areas to 4-20mA for safe-area loads. Supports eight thermocouple types and 2-, 3-, and 4-wire RTDs.
Product Details
Reliable Temperature Conversion for Hazardous Areas
In industrial processes where temperature sensors are located in hazardous areas, reliable signal conversion is critical for safe and accurate monitoring. The MTL3073 temperature converter from MTL is engineered to convert low-level DC signals from thermocouples and RTDs into a robust 4-20mA output for safe-area loads. With its intrinsic safety certification, it ensures reliable operation in Zone 0, IIC, T4 hazardous areas and Div. 1, Group A locations.
Engineers often face challenges with signal integrity, temperature drift, and configuration flexibility. The MTL3073 addresses these by offering software-selectable linearisation, ranging, and monitoring for eight thermocouple types and 2-, 3-, and 4-wire RTDs. Whether you’re upgrading an existing system or building a new one, this converter delivers genuine reliability at competitive prices.

Key Features and Technical Specifications
- Accepts eight thermocouple types (J, K, T, E, R, S, B, N) and 2-, 3-, or 4-wire RTDs.
- 4-20mA output with maximum load resistance of 600Ω.
- Input signal range: –75 to +75mV or 0 to 400Ω; span 3 to 150mV or 10 to 400Ω.
- Calibration accuracy: ±15µV or ±0.05% for mV/THC inputs; ±80mΩ for RTD inputs.
- Temperature drift as low as ±0.003% of input value/°C for mV/THC.
- 250V AC isolation between safe- and hazardous-area circuits.
- Power consumption: 57mA at 24V; 1.2W dissipation at 24V with 20mA signal.
- Green LED for power and status indication.
- Configuration via PC with PCL45 interface and PCS45 software.
- Compact and lightweight: 170g.
A standout feature is the automatic cold junction compensation (CJC) with an integral sensor, ensuring accurate thermocouple readings without external hardware. The CJC error is ≤1.0°C, enhancing measurement reliability in critical processes.
Applications and Use Cases
The MTL3073 is ideal for chemical, petrochemical, and pharmaceutical plants where temperature sensors reside in hazardous zones. It reliably transmits signals from thermocouples or RTDs to control systems in safe areas, ensuring accurate process monitoring. In a typical scenario, a reactor temperature is measured by a Type K thermocouple in Zone 1; the MTL3073 converts the low-level signal to 4-20mA, which is then fed to a PLC for precise control. Its high common mode rejection (120dB) and series mode rejection (40dB) minimise noise, making it suitable for electrically noisy environments.

Installation and Setup
Installation requires mounting the module in a safe area, connecting hazardous-area sensor wiring to terminals 5-8, and safe-area output to the load. Ensure power supply is within 20-35V DC range. Configuration is straightforward using a PC with PCL45 interface and PCS45 software; default settings include Type K thermocouple, 0-250°C range, and upscale burnout alarm. For detailed wiring diagrams and safety parameters, consult the official datasheet.
Maintenance and Reliability
The MTL3073 is designed for long-term reliability with minimal maintenance. Regular inspection of wiring connections and sensor integrity is recommended. The replaceable 100mA fuse protects against faults. Operating temperature range and environmental factors should be within specifications to ensure optimal performance. With its robust isolation and drift characteristics, the converter minimises downtime and maintenance costs, contributing to overall operational efficiency.
Compatibility and Integration
The MTL3073 integrates seamlessly with most PLCs and control systems via its 4-20mA output. For fieldbus networks such as PROFINET or EtherNet/IP, an external gateway or connection module may be required. It is advisable to confirm cable and gateway compatibility with the supplier. The module’s intrinsic safety parameters allow direct connection to sensors in hazardous areas without additional barriers, simplifying system design.
Comparison with Similar Products
- MTL3073 vs. MTL3072: The MTL3073 offers wider input range and supports more thermocouple types, enhancing flexibility.
- MTL3073 vs. generic temperature transmitters: The MTL3073 provides certified intrinsic safety and superior accuracy, ensuring reliable operation in hazardous areas.
- MTL3073 vs. loop-powered isolators: The MTL3073 includes advanced features like CJC and software configuration, reducing setup time and errors.
Frequently Asked Questions
Q: What is the operating temperature range of the MTL3073?
A: The MTL3073 is designed for operation in ambient temperatures typically from -20°C to +60°C. For precise limits, refer to the official MTL datasheet.
Q: Can the MTL3073 be used with 3-wire RTDs?
A: Yes, the MTL3073 supports 2-, 3-, and 4-wire platinum RTDs to BS 1904/DIN 43760 (100Ω at 0°C).
Q: What is the maximum load resistance for the 4-20mA output?
A: The maximum load resistance is 600Ω, ensuring compatibility with a wide range of safe-area loads.
Q: How is the MTL3073 configured?
A: Configuration is done via a PC using the PCL45 interface and PCS45 software, allowing selection of input type, ranging, linearisation, and alarms.
Product Support and Availability
The MTL3073 is in stock and ready to ship from Mronexus. As your one-stop sourcing base for genuine industrial automation parts, we ensure fast delivery and competitive prices. Contact Mronexus for genuine industrial automation parts and experience reliable service.