2198-C4004-ERS | Allen-Bradley Kinetix 5300 Servo Drive 0.86 kW
PLC
- Brand: Allen-Bradley
- Part Number:
2198-C4004-ERS - Availability: Ask for quote
The Allen-Bradley 2198-C4004-ERS is a Kinetix 5300 single-axis servo drive delivering 0.86 kW at 400V AC with dual-port EtherNet/IP and hardwired Safe Torque Off for reliable integrated motion.
Product Details
Model: 2198-C4004-ERS
Brand: Allen-Bradley (Rockwell Automation)
Series: Kinetix 5300 Servo Drive
Kinetix 5300 single-axis EtherNet/IP servo drive, 380…480V AC, three-phase, 0.86 kW at 400V AC three-phase, 1.6 A continuous output current, Frame 1, IP20, hardwired Safe Torque Off and dual-port EtherNet/IP.
── Hardware ──
Product type: single-axis servo drive for integrated motion on EtherNet/IP — Kinetix 5300 (catalog prefix 2198-C) (per KNX-TD003N-EN-P p. 92)
Drive family: Kinetix 5300 (2198-Cxxxx-ERS), 0.22…14.70 kW, 110V, 230V and 400V classes (per KNX-TD003N-EN-P pp. 93…95)
Catalog number structure: 2198-C4004-ERS: drive 2198-C, power/frame code 4004, -ERS = EtherNet/IP servo drive with hardwired Safe Torque Off (per 2198-UM005E-EN-P p. 23, Table 3 — Kinetix 5300 Servo Drives). SUG-14: the 1004/2055-style suffix has no official per-digit structure chart; the suffix-to-rating grouping is inferred from the drive ratings table, i.e. (per drive ratings table grouping), not from a catalog-number explanation
Frame size: 1 (per 2198-UM005E-EN-P p. 23, Table 3)
Control: integrated motion on the EtherNet/IP network using the Studio 5000 Logix Designer application and Logix 5000 controllers (per KNX-TD003N-EN-P p. 92)
Feedback: motor feedback (MFB) connector plus auxiliary feedback connector; the drive also accepts high-resolution and incremental feedback types (per KNX-TD003N-EN-P p. 92 and 2198-UM005E-EN-P p. 18)
Communication: dual-port EtherNet/IP (PORT1 and PORT2 RJ45 connectors) with hardwired Safe Torque Off and standard inputs (per KNX-TD003N-EN-P p. 92)
AC line filter: 2198-DB08-F is the recommended filter for this catalog number for CE compliance (KNX-TD003N-EN-P AC Line Filter Selection, p. 107)
AC line filter specification: 2198-DB08-F — 528V AC three-phase 50/60 Hz voltage rating, maximum current 7.5 A at 50 °C (122 °F), power loss 3.6 W, leakage current 2.5 mA, weight 0.77 kg (1.70 lb), operating temperature 0…50 °C (32…122 °F) (per KNX-TD003N-EN-P p. 107, 2198-DBxxx-F AC Line Filter Specifications), footnote: applies to installations with single-phase or three-phase input power
Feedback connector kit: 2198-K53CK-D15M passes feedback signals straight through from the encoder to the drive MFB connector and accepts Hiperface high-resolution absolute (multi-turn and single-turn), Nikon (24-bit) high-resolution serial encoder, Tamagawa (17-bit) high-resolution serial encoder, Digital AqB (TTL) with UVW (incremental) and generic sin/cos with UVW (incremental); it is published for new installations with flying-lead motor/actuator cables and for upgrades of existing motor/actuator installations (per KNX-TD003N-EN-P p. 109)
24V DC shared-bus control power: the drive supports the zero-stack feature with the 24V shared-bus connection system to extend control power to multiple drives; the kit is 2198-TCON-24VDCIN36 input wiring connector (frames 1, 2 and 3) plus 2198-H040-P-T T-connector with two bus-bar connectors for Frame 1 drives, and the published IMPORTANT note requires the zero-stack tab and cutout to be engaged between adjacent drives (per KNX-TD003N-EN-P p. 108)
Replacement connector set: 2198-CONKIT-PWR20 — one shunt connector, AC input power, control power, motor power, motor brake, digital inputs and auxiliary feedback, safe torque-off connector and clamp spacer (published for Frame 1 and Frame 2 drives except 2198-C2030-ERS) (per KNX-TD003N-EN-P p. 110, Replacement Parts – Kinetix 5300 Servo Drives; connector sets are included with each drive)
Cooling: a cooling fan is shown on the Kinetix 5300 bottom view, which the document labels “frame 2 and 3 drives only” (per KNX-TD003N-EN-P p. 92); the fan “runs as part of the control power startup routine, when the inverter is enabled, and if the inverter temperature exceeds preset threshold” (per KNX-TD003N-EN-P p. 93, footnote 2). No cooling method is published for Frame 1 drives, so none is asserted here
── Drive Ratings ──
Continuous output power: 0.86 kW at 400V AC three-phase (per KNX-TD003N-EN-P p. 94…95, Input Power Specifications — Kinetix 5300, column 2198-C4004-ERS)
Continuous output current: 1.6 A (rms) (per KNX-TD003N-EN-P p. 94…95, Input Power Specifications — Kinetix 5300, column 2198-C4004-ERS)
Continuous output current (0-pk): 2.3 A (per KNX-TD003N-EN-P p. 94…95, Input Power Specifications — Kinetix 5300, column 2198-C4004-ERS)
Peak output current: 5.3 A (rms), allowed for up to 1.0 s (per KNX-TD003N-EN-P p. 94…95, Input Power Specifications — Kinetix 5300, column 2198-C4004-ERS, footnote 4)
Peak output current (0-pk): 7.5 A (per KNX-TD003N-EN-P p. 94…95, Input Power Specifications — Kinetix 5300, column 2198-C4004-ERS)
Main AC input current: 1.24 A (rms) (per KNX-TD003N-EN-P p. 94…95, Input Power Specifications — Kinetix 5300, column 2198-C4004-ERS)
Peak AC input current: 3.59 A (rms) (per KNX-TD003N-EN-P p. 94…95, Input Power Specifications — Kinetix 5300, column 2198-C4004-ERS)
Output voltage: no rated output voltage line is published for the Kinetix 5300 drive tables; the AC input voltage per class is published instead (per KNX-TD003N-EN-P p. 94…95, Input Power Specifications — Kinetix 5300, column 2198-C4004-ERS)
Output frequency: 0…590 Hz maximum (per 2198-UM005E-EN-P p. 191 — Output frequency, max)
Efficiency: 97 % (per KNX-TD003N-EN-P p. 94…95, Input Power Specifications — Kinetix 5300, column 2198-C4004-ERS)
Line loss ride-through: 20 ms (per KNX-TD003N-EN-P p. 94…95, Input Power Specifications — Kinetix 5300, column 2198-C4004-ERS)

Internal shunt resistor: 100 Ω, 30 W (per KNX-TD003N-EN-P p. 94…95, Input Power Specifications — Kinetix 5300, column 2198-C4004-ERS)
External shunt compatibility: 2097-R6, 2097-R7 — 2097-R6 75 Ω / 150 W / 0.3 kg; 2097-R7 150 Ω / 80 W / 0.2 kg (per KNX-TD003N-EN-P p. 106, Passive-shunt and Drive Compatibility and Shunt Module Specifications; shunt resistor selection is based on the needs of the actual hardware configuration)
Internal shunt on: 775V; internal shunt off: 765V (per KNX-TD003N-EN-P p. 94…95, Input Power Specifications — Kinetix 5300, column 2198-C4004-ERS)
Bus overvoltage limit: 810V (per KNX-TD003N-EN-P p. 94…95, Input Power Specifications — Kinetix 5300, column 2198-C4004-ERS)
Bus undervoltage limit: 275V (per KNX-TD003N-EN-P p. 94…95, Input Power Specifications — Kinetix 5300, column 2198-C4004-ERS)
DC bus capacitance: 165 µF (per KNX-TD003N-EN-P p. 94…95, Input Power Specifications — Kinetix 5300, column 2198-C4004-ERS)
Short-circuit current rating: 200,000 A (rms) symmetrical (per KNX-TD003N-EN-P p. 94…95, Input Power Specifications — Kinetix 5300, column 2198-C4004-ERS)
Overload: 110 % of motor rating with solid-state fold-back (UL61800-5-1 File E59272) (per KNX-TD003N-EN-P p. 105, cULus listing note)
── Control I/O ──
Digital inputs: 4 configurable 24V DC current-sinking fast inputs (IN1…IN4) on the digital inputs and auxiliary feedback connector; the drive has four configurable digital inputs and seven configurable functions to choose from in the Logix Designer application, and although any input can be configured as a registration input, only two can be registration inputs at any one time (per 2198-UM005E-EN-P p. 53, Tables 16 and 17). The published input specification table gives 2.5 mA typical input current, 15…26.4V DC typical ON voltage range, 5V DC maximum OFF voltage, IEC 61131-2 24V DC Type 1, optically isolated and reverse-voltage-protected inputs, and 24V DC ±10 % PELV external power supply (per 2198-UM005E-EN-P p. 55, Table 22)
Analog inputs: no analog input is published for the Kinetix 5300 — the control-signal specifications of 2198-UM005E-EN-P pp. 55…57 describe digital inputs, the motor holding-brake circuit, control power, Ethernet communication and feedback only, and no analog-input connector, range or resolution line appears anywhere in that publication or in the Kinetix 5300 pages of KNX-TD003N-EN-P, so none is asserted here
Motor brake output: the holding-brake option is a spring-set brake released through a solid-state relay from a customer-supplied 24V supply; the MBRK+ and MBRK– connections are rated 2.25 A @ +24V, the driver provides brake current-overload and brake overvoltage protection, the switching frequency must not exceed 15 cycles/min, and engage and release delays are set by the MechanicalBrakeEngageDelay and MechanicalBrakeReleaseDelay settings whose values come from the KNX-TD001 motor brake tables (per 2198-UM005E-EN-P pp. 55…56, Motor Holding-brake Circuit and Figure 29)
Relay outputs: no general-purpose relay output or relay-output rating table is published for the Kinetix 5300; the only relay element in the connector data is the solid-state motor holding-brake driver recorded above, so no relay output is asserted here (per 2198-UM005E-EN-P pp. 55…57)
Carrier frequency: no carrier-frequency or PWM-switching-frequency rating is published for the Kinetix 5300 — 2198-UM005E-EN-P refers to the PWM output waveform only in a device-compatibility caution (p. 27) and a wiring-practice note (p. 65), the Kinetix 5300 pages of KNX-TD003N-EN-P (pp. 92…110) contain no switching-frequency entry, and “carrier” appears in KNX-TD003N-EN-P only as the mechanical fan carrier of a replacement part, so no carrier frequency is stated here
Accel/decel: no fixed acceleration or deceleration time rating is published for the Kinetix 5300; velocity ramps come from the Logix Ramp Generator attributes — RampAcceleration and RampDeceleration are positive values defining the maximum increasing and decreasing speed of the velocity command output by the Ramp Generator, and RampJerk – Control sets the percentage of that time applied as a jerk-limited S-curve, half at the beginning and half at the end of the ramp, with 0 giving a linear ramp and 100 % a triangular profile (per 2198-UM005E-EN-P p. 221). The motor-test ramp uses these attributes and substitutes 10 seconds whenever the resulting time is shorter or unsupported (per 2198-UM005E-EN-P p. 209)
Speed regulation / frequency accuracy: no numeric speed-regulation or frequency-accuracy figure is published for the Kinetix 5300 — the only occurrence of “speed regulation” in 2198-UM005E-EN-P is the qualitative statement that sensorless vector control offers better torque production and speed regulation than basic volts/hertz (p. 194), and the published accuracy figures relate to the registration inputs: registration accuracy ±3 µs and registration repeatability 1.0 µs (per 2198-UM005E-EN-P pp. 55 and 194, Table 22)
Stop modes: Safe Torque Off turns off the inverter power transistors in response to a monitored digital input according to Stop Category 0 behaviour — “Stop Category 0 as defined in EN/IEC 60204-1 or Safe Torque Off as defined by EN/IEC 61800-5-2 is achieved with immediate removal of motion-producing power to the actuator” — and the STO circuit is used with other safety devices to achieve Stop Category 0 and protection-against-restart per EN/IEC 60204-1; the fault behaviour table assigns a Best Available Stopping Action per fault class, the default drive stop action is Current Decel & Disable, and a servo-off is commanded with the Motion Servo Off (MSF) instruction after decelerating to 0 rpm with Motion Axis Stop (MAS) (per 2198-UM005E-EN-P pp. 64, 154 and 160, Stop Category Definition, p. 143 Table 77 and p. 56)
Auxiliary feedback: AM, BM and IM differential inputs plus a 5V encoder power output (AUX_EPWR_5V) and auxiliary common on the digital inputs and auxiliary feedback connector (per 2198-UM005E-EN-P p. 53, Table 16)
Motor feedback: dedicated 15-pin MFB connector; 2198-K53CK-D15M is the published 15-pin motor-feedback connector kit for flying-lead cables (per 2198-UM005E-EN-P pp. 18 and 23, Table 4)
Safe Torque Off: dual-channel hardwired input on the STO connector; TÜV certified for functional safety when used as described in 2198-UM005E-EN-P — up to Performance Level (PL) d, Category 3 according to ISO 13849 and up to SIL CL2 according to IEC 61508, IEC 61800-5-2 and IEC 62061 (per KNX-TD003N-EN-P p. 105)
Status display: four-character status display with navigation pushbuttons, module and network status indicators and link / link-speed status indicators (per KNX-TD003N-EN-P p. 92 and 2198-UM005E-EN-P p. 51)
── Communication ──
Built-in ports: 2 × EtherNet/IP (RJ45, PORT1 and PORT2) (per KNX-TD003N-EN-P p. 92)
Protocol: EtherNet/IP with integrated motion; linear, Device Level Ring (DLR) and star topologies are supported, and a DLR supervisor is required for ring operation (per 2198-UM005E-EN-P pp. 13 and 20)
Embedded Ethernet switch: three-port cut-through switch with time correction on IEEE-1588 packets, limited filtering and Quality of Service with four priority levels; the drive auto-negotiates speed and duplex (100BASE-TX full-duplex recommended for maximum performance) with auto MDI/MDIX detection and correction; cyclic update period 1.0 ms minimum, port-to-port time synchronization variation 100 ns maximum, cabling CAT5e shielded up to 100 m (328 ft) (per 2198-UM005E-EN-P p. 57, Ethernet Communication Specifications)
Conformance: ODVA EtherNet/IP conformance tested and CIP Security conformance tested (per KNX-TD003N-EN-P p. 105)
No separate communication option-card slot: the network, input and Safe Torque Off connections are built into the drive housing listed on KNX-TD003N-EN-P p. 92
Serial / Modbus: no RS-485 port and no Modbus support line is published for the Kinetix 5300 series — EtherNet/IP is the only network interface of the 2198-Cxxxx-ERS catalog numbers (per 2198-UM005E-EN-P p. 23, Table 3 and KNX-TD003N-EN-P p. 92)
── Electrical ──
Input voltage: 342…528V rms three-phase (380…480V AC nominal) (per KNX-TD003N-EN-P p. 94…95, Input Power Specifications — Kinetix 5300, column 2198-C4004-ERS)
Input frequency: 47…63 Hz (per KNX-TD003N-EN-P p. 94…95, Input Power Specifications — Kinetix 5300, column 2198-C4004-ERS)

Control power input: 21.6…26.4V DC (24V DC nominal) (per KNX-TD003N-EN-P p. 94…95, Input Power Specifications — Kinetix 5300, column 2198-C4004-ERS)
Control power input current (non-brake motors): 0.4 A DC (per KNX-TD003N-EN-P p. 94…95, Input Power Specifications — Kinetix 5300, column 2198-C4004-ERS, footnote 3 — for motors with a holding brake see Control Power Current Specifications, p. 96)
Max inrush current: 15.5 A (0-pk) (per KNX-TD003N-EN-P p. 94…95, Input Power Specifications — Kinetix 5300, column 2198-C4004-ERS)
Power cycle limitation: drives are limited to one power cycle per minute (per KNX-TD003N-EN-P p. 94…95, Input Power Specifications — Kinetix 5300, column 2198-C4004-ERS, footnote 1)
Transistor type: no transistor-type or PWM-output specification line is published for the Kinetix 5300; the user manual refers to the output stage only as an IGBT circuit in the Safe Torque Off ATTENTION warning (“If there are two simultaneous faults in the IGBT circuit, permanent magnet motors can result in a rotation of up to 180 electrical degrees”) (per 2198-UM005E-EN-P p. 155)
Power dissipation (watts at 20 / 40 / 60 / 80 / 100 % of rated power output): 380…480V three-phase: 16 / 21 / 26 / 31 / 36 — published per nominal AC input class, for enclosure sizing and ventilation calculations; internal shunt power is not included and must be added based on utilization (per KNX-TD003N-EN-P p. 101, Power Dissipation Specifications, footnote 1)
── Environmental ──
Operating temperature: 0…50 °C (32…122 °F) operational range (per KNX-TD003N-EN-P p. 105, Environmental Specifications — Kinetix 5300 Servo Drives)
Storage temperature: -35…+70 °C (-31…+158 °F) storage range (nonoperating) (per KNX-TD003N-EN-P p. 105)
Relative humidity: 5…85 % non-condensing (operating); 5…95 % non-condensing (storage) (per KNX-TD003N-EN-P p. 105)
Degree of pollution: 2 (IEC 61800-5-1) (per KNX-TD003N-EN-P p. 105)
Altitude: 1000 m (3281 ft) for both the operational and the storage range (per KNX-TD003N-EN-P p. 105)
Vibration: 5…55 Hz at 0.35 mm (0.014 in.) double amplitude, continuous displacement; 55…500 Hz at 2.0 g peak constant acceleration, ten sweeps in each of three mutually perpendicular directions (per KNX-TD003N-EN-P p. 105)
Shock: 15 g, 11 ms half-sine pulse, 3 pulses in each direction of 3 mutually perpendicular directions; the published table states the limit without citing a test standard (per KNX-TD003N-EN-P p. 105)
Seismic / surge immunity: no seismic qualification and no surge-withstand rating is published for the Kinetix 5300 — the environmental table of KNX-TD003N-EN-P p. 105 lists temperature, humidity, pollution degree, altitude, vibration and shock only, and neither “seismic” nor “surge” appears anywhere in KNX-TD003N-EN-P or 2198-UM005E-EN-P, so no SEMI F47, IEC 61000-4-5 or seismic figure is stated here
Protection class and enclosure: IP20 (IEC 60529); the drive is intended for mounting inside a grounded enclosure (per KNX-TD003N-EN-P p. 105)
Three-proofing / coating: no conformal-coating class (IEC 60721-3-3) is published for the Kinetix 5300 series; only the IP20 protection class and pollution degree 2 are specified (KNX-TD003N-EN-P p. 105)
Input current harmonics: no per-catalog-number total harmonic distortion (THD) figure, harmonic spectrum or EN 61000-3-2 / IEC 61000-3-12 compliance statement is published for the Kinetix 5300 series; EN 61800-3 EMC compliance is shown against the CE entry and the external AC line filter selection in KNX-TD003N-EN-P p. 107
── Physical ──
Dimensions (H×W×D): 175.0 H × 50.0 W × 204.0 D mm (Frame 1 mounting dimensions, per KNX-TD003N-EN-P Dimensions – Kinetix 5300 Servo Drives, p. 103)
Weight: 1.34 kg (Frame 1; the official table column is headed “Weight, approx kg (lb)”, per KNX-TD003N-EN-P Weight Specifications, pp. 101…102)
Motor cable length: 30 m (98.4 ft) maximum for the drive limits table in 2198-UM005E-EN-P p. 191; the Kinetix 5300 maximum-cable-length table gives 50 m (164 ft) for absolute high-resolution feedback at ≤400V AC input and 20 m (65.6 ft) at 480V AC input, 30 m (98.4 ft) for incremental encoder feedback at ≤400V and 20 m (65.6 ft) at 480V (per KNX-TD003N-EN-P p. 102, Maximum Cable Lengths)
── Certifications ──
Agency certification: cULus — UL Listed to US and Canadian safety standards (UL61800-5-1, File E59272). The listing note states that solid-state motor overload protection provides dynamic fold-back of motor current when 110 % of the motor rating is reached, with a peak current limit based on the peak motor rating as investigated by UL to comply with UL61800-5-1 (per KNX-TD003N-EN-P p. 105). Footnote: UL has not evaluated the Safe Torque Off option in these products.
CE: EMC Directive 2004/108/EC (IEC 61800-3:2004 + A1:2012); Low Voltage Directive 2006/95/EC (IEC 61800-5-1:2007) — transcribed as published in the Kinetix 5300 certifications table; these are the superseded directive versions, which 2198-UM005E-EN-P does not restate (per KNX-TD003N-EN-P p. 105, Certifications — Kinetix 5300 Servo Drives)
Functional safety: TÜV certified for functional safety when used as described in the Kinetix 5300 Servo Drives User Manual, publication 2198-UM005. The 2198-Cxxxx-ERS (hardwired safety) drive ratings are up to Performance Level (PL) d, Category 3 according to ISO 13849, and up to SIL CL2 according to IEC 61508, IEC 61800-5-2 and IEC 62061 (per KNX-TD003N-EN-P p. 105)
RCM: Australian Radiocommunications Act, compliant with the Radiocommunications Act 1992 (including amendments up to 2017), the Radiocommunications (Electromagnetic Compatibility) Standard 2017, the Radiocommunications Labeling (Compliance Labelling — Incidental Emissions) Notice 2017 and AS/NZS CISPR 11:2002 (Group 1, Class A) (per KNX-TD003N-EN-P p. 105)
KC: Korean Registration of Broadcasting and Communications Equipment, compliant with Article 58-2 of the Radio Waves Act, Clause 3, registration number KCC-REM-RAA-2198 (per KNX-TD003N-EN-P p. 105)
ODVA: EtherNet/IP conformance tested and CIP Security conformance tested (per KNX-TD003N-EN-P p. 105)
Ecodesign: IE2 efficiency class per Ecodesign Regulation EU 2019/1781 (per KNX-TD003N-EN-P p. 105)
Noise: maximum audible noise from the servo drive system complies with OSHA standard 3074, Hearing Conservation (<85 dBA) (per KNX-TD003N-EN-P p. 105)
Cybersecurity: CIP Security conformance tested (per KNX-TD003N-EN-P p. 105, ODVA entry). 2198-UM005E-EN-P carries a dedicated CIP Security page in its front matter and describes “CIP Security-enabled Rockwell Automation products, for example, the product described in this publication”; it states that CIP Security “is a standard, open-source communication method that helps to provide a secure data transport across an EtherNet/IP network” and “lets CIP-connected devices authenticate each other before transmitting and receiving data”, using the security properties Device Identity and Authentication, Data Integrity and Authentication, and Data Confidentiality; the same page names the products Rockwell Automation uses to implement CIP Security — FactoryTalk Services Platform 6.11 or later with FactoryTalk Policy Manager and FactoryTalk System Services enabled, FactoryTalk Linx 6.11 or later, and Studio 5000 Design Environment 32.00.00 or later — and points to the CIP Security with Rockwell Automation Products Application Technique, publication SECURE-AT001 (per 2198-UM005E-EN-P p. 10). No Achilles Field Coupled Test Method certification level and no IEC 62443 security provision or capability level is published for the Kinetix 5300 series in either cited publication
Explosion protection (ATEX / IEC Ex): no ATEX, UKEX or IEC Ex hazardous-area certification is published for the Kinetix 5300 series — the p. 105 certification table lists cULus, CE, functional safety, RCM, KC, ODVA, OSHA and Ecodesign entries and no hazardous-area entry (per KNX-TD003N-EN-P p. 105)
Marine and other industry certifications: no Lloyd’s Register, DNV or other marine type approval is published for the Kinetix 5300 series in 2198-UM005E-EN-P or KNX-TD003N-EN-P — neither name occurs anywhere in either publication, and the certification content of 2198-UM005E-EN-P (Agency Compliance p. 24 and Certification p. 153) and KNX-TD003N-EN-P p. 105 lists cULus, CE, UKCA, functional safety and ODVA entries with no marine row
── Source Provenance ──
Source tier: Primary — manufacturer-published technical documentation only (Allen-Bradley / Rockwell Automation publications)
Publications cited by this record: 2 — KNX-TD003N-EN-P (Jun 2026, 150 pages); 2198-UM005E-EN-P (Sep 2024, 240 pages)
Document types: Technical Data publications, User Manuals
Cross-check: two or more independent official publications agree on this record
Specification lines: 84 (counted over the specification sections only; the 8 Data Notes lines and the lifecycle keys are excluded). Lines carrying both a publication code and a printed page, table or figure anchor: 83 of 84 (99 %); publication code without a page anchor: 0 (0 %); no publication code at all: 1 (1 %). Counting rule: a line is anchored when it matches a publication code and one of “p.
Published-but-absent items recorded as explicit negative findings: 14 (each names the publication and the pages searched)
Field-level attribution — vendor catalogue data: Rockwell Automation product data (official vendor product catalogue) supplies the catalog-number attributes and the lifecycle status. Fields that carry it: none. Every other field is attributed inside the line itself, in the form “(per
Non-official sources: none. No distributor listing, no reseller dataset, no encyclopaedic or community source and no vendor marketing copy is used.
Derivation policy: values are transcribed from published tables only; frame-level values are disclosed as frame-level rather than per-catalog; where two official publications state different values the record adopts one, states the adopted value, and gives the reason (page role, majority of sources, or rating-code agreement); typographical errors in the source are reproduced and flagged rather than corrected silently.
Cross-document conventions: no second publication restates a value of this record under a different rating label.
Reference date: verified 2026-10 against the current revision of every cited publication
── Data Notes ──
Power and current values are cross-checked between two official documents: the Kinetix 5300 servo drive table in 2198-UM005E-EN-P (Sep 2024), Table 3, p. 23 and the per-catalog columns of the Input Power Specifications tables in KNX-TD003N-EN-P (Jun 2026), pp. 93…95; both sources agree for every catalog number. The 110V single-phase, 230V single-phase and 230V three-phase columns are distinct ratings of the same catalog number, not separate models.
Peak output current is permitted for up to 1.0 s (KNX-TD003N-EN-P pp. 93…95, footnote 4).
Fields the official documents do not publish are recorded as unpublished rather than filled by analogy: the Kinetix 5300 tables contain no rated output-voltage line, no transistor-type or PWM-output line, and no cooling-method statement for Frame 1 drives; and, on the same basis, no analog input, no general-purpose relay output, no carrier or PWM switching frequency, no fixed accel/decel time rating, no numeric speed-regulation or frequency-accuracy figure, and no seismic or surge-withstand rating is published for the series — each of those is recorded as a verified absence naming the pages searched, while the related figures the documents do publish (registration timing accuracy, the solid-state motor-brake relay, the cyclic update period and the Stop Category 0 definition) are recorded as values.
Capacitive energy absorption is omitted for this catalog number: the KNX-TD003N-EN-P p. 95 continuation table prints three values (8.13 J / 13.79 J / 16.26 J) against the four 2198-C40xx-ERS columns, so the column mapping is ambiguous and no value is asserted.
Dimensions are from KNX-TD003N-EN-P (Jun 2026), Dimensions – Kinetix 5300 Servo Drives, p. 103. Weights are from the Kinetix 5300 weight table in KNX-TD003N-EN-P, pp. 101…102.
The AC line filter is selected per catalog number from KNX-TD003N-EN-P AC Line Filter Selection, p. 107; the drive is not supplied with an internal EMC filter.
Certification page: the published-value entries in the Certifications and Environmental sections above are from the Environmental Specifications and Certifications – Kinetix 5300 Servo Drives tables on p. 105 of KNX-TD003N-EN-P (Jun 2026); the KNX-TD003N document also contains separately certified Kinetix 5100, 5500 and 5700 tables, and those values are not used here. Control-signal, connector, stop-behaviour and Ethernet switch entries are from 2198-UM005E-EN-P (Sep 2024) pp. 53…57, 64, 143, 154, 160, 209 and 221.
Sources: 2198-UM005E-EN-P (Sep 2024) for drive ratings and control functions; KNX-TD003N-EN-P (Jun 2026) for dimensions, weights, AC line filters, environmental and certification data; Rockwell Automation product data (2026-10) for catalog-number attributes and lifecycle status.
Commercial data (price, stock, lead time, distributor, MOQ, HS code, country of origin) is outside the scope of this technical record and is intentionally absent.
── Lifecycle ──
Current: active catalog number in the official Rockwell Automation product data; no discontinuation date published (Last verified: 2026-10)
Replacement: No replacement classification (active product; no discontinuation published)
Discontinuation Date: N/A (active product)
Unmatched Customer Service
- After Hours Shipping
- Real Time Order Tracking
- Flexible Delivery Options
- Intact Technical Supports