3RW4423-1BC44 | Siemens SIRIUS Soft Starter 36A 18.5kW
PLC
- Brand: Siemens
- Part Number:
3RW4423-1BC44 - Availability: Ask for quote
Siemens 3RW4423-1BC44 SIRIUS soft starter: 36A, 18.5kW, 200-460V AC, inside-delta 62A/30kW. Reliable motor control with integrated protection and bypass.
Product Details
Introduction
For decades, industrial motor control has evolved from crude direct-on-line starters to sophisticated soft starters that protect equipment and extend service life. The Siemens 3RW4423-1BC44 SIRIUS soft starter represents this evolution, combining reliable engineering with advanced features for modern automation. As a genuine Siemens product, it delivers the performance and durability that engineers expect, and it is available from Mronexus at competitive prices with fast worldwide shipping from stock.

Product Overview
The 3RW4423-1BC44 is a SIRIUS soft starter designed for high-feature applications. It provides controlled acceleration and deceleration of three-phase motors, reducing mechanical stress and electrical disturbances. With a rated operating current of 36A at 40°C and a power rating of 18.5kW at 400V in standard circuit, it suits a wide range of motor control tasks. The integrated bridging contact system and thyristors ensure smooth starting, while built-in motor overload protection and thermal resistor evaluation safeguard the motor.
Key Features & Technical Specifications
- Operating voltage: 200-460V AC (standard circuit), with -15%/+10% tolerance.
- Control supply voltage: 230V AC at 50/60Hz, with -15%/+10% tolerance.
- Rated current: 36A at 40°C (standard), 62A at 40°C (inside-delta).
- Motor power: 18.5kW at 400V (standard), 30kW at 400V (inside-delta).
- Operating temperature: up to 60°C ambient, with current derating above 40°C.
- Integrated bridging contact system and thyristors for smooth starting.
- Motor overload protection with adjustable current limitation (7A minimum).
- 3 NO + 1 changeover auxiliary contacts for flexible control integration.
- Screw terminals for main and control circuits, accepting up to 70mm² conductors.
- Dimensions: 170 x 192 x 270 mm (W x H x D); IP00 protection.
The operating temperature range is particularly noteworthy: with derating, the soft starter can operate at up to 60°C, making it suitable for challenging industrial environments. The 230V AC control supply simplifies integration with standard control panels, and the communication protocol is via hardwired auxiliary contacts, ensuring reliable status feedback.

Applications & Use Cases
The 3RW4423-1BC44 excels in applications where controlled motor starting is critical. In pump systems, it reduces water hammer and extends pipe life. For conveyor belts, it minimizes mechanical shock and product damage. Fans and blowers benefit from reduced belt wear and smoother operation. In inside-delta configuration, it handles larger motors up to 30kW, making it ideal for heavy-duty compressors and mixers. The integrated bypass contactor reduces energy losses during running, contributing to lower operating costs.
Installation & Setup
Mount the soft starter on a vertical plane, allowing ±90° rotation and ±22.5° tilt for optimal access. Maintain clearances: 100mm above, 75mm below, and 5mm sideways to ensure proper heat dissipation. Connect main conductors to the box terminals using screw fixing; the terminals accept solid or stranded conductors up to 70mm². For control wiring, use the screw-type auxiliary terminals. Ensure the 230V AC control supply is stable and protected. The maximum cable length is 500m, supporting remote installation.
Compatibility & Integration
The 3RW4423-1BC44 integrates seamlessly with Siemens SIRIUS control systems and standard motor protection devices. The auxiliary contacts (3 NO + 1 changeover) provide status signals to PLCs or HMIs. For network integration, the soft starter can be combined with external gateways or connection modules to interface with PROFINET or EtherNet/IP; confirm cable and gateway compatibility with the supplier. The 230V AC control supply is common in industrial panels, simplifying retrofit projects.
Maintenance & Reliability
Regular inspection every 6-12 months is recommended, focusing on terminal tightness, dust accumulation, and cooling clearance. The thyristors and bridging contactor are robust, but environmental factors such as high temperature and humidity can affect longevity. Operating within the specified temperature range and ensuring proper ventilation will maximize service life. The integrated motor overload protection reduces the risk of motor burnout, lowering downtime and repair costs.
Frequently Asked Questions
Q: What is the operating temperature range of the 3RW4423-1BC44?
A: The soft starter operates up to 60°C ambient temperature, with current derating above 40°C. At 50°C, rated current is 32A; at 60°C, 29A. Storage temperature range is -25°C to +80°C.
Q: Can the 3RW4423-1BC44 be used in an inside-delta circuit?
A: Yes, it supports inside-delta connection with rated current 62A at 40°C and motor power up to 30kW at 400V. This allows handling larger motors with a smaller frame size.
Q: What input voltage does the 3RW4423-1BC44 require?
A: The main circuit accepts 200-460V AC (-15%/+10%), and the control supply requires 230V AC at 50/60Hz. Ensure the control voltage matches the available supply.
Q: Does the 3RW4423-1BC44 include motor overload protection?
A: Yes, it features intrinsic device protection, motor overload protection, and evaluation of thermal resistor motor protection. Adjustable current limitation and external reset are also included.
Product Support & Availability
The Siemens 3RW4423-1BC44 is in stock and ready to ship from Mronexus. As your one-stop sourcing base for genuine industrial automation parts, we offer fast delivery and competitive prices. Contact Mronexus for genuine industrial automation parts and experience reliable service.
Unmatched Customer Service
- After Hours Shipping
- Real Time Order Tracking
- Flexible Delivery Options
- Intact Technical Supports