3RW4434-6BC44 | Siemens SIRIUS Soft Starter 55kW/110kW
PLC
- Brand: Siemens
- Part Number:
3RW4434-6BC44 - Availability: Ask for quote
Siemens 3RW4434-6BC44 SIRIUS soft starter delivers 55kW standard or 110kW inside-delta motor control with 200-460V AC input, 230V AC control, and advanced protection features.
Product Details
When High Inrush Current Threatens Your Motor and Grid
Engineers commissioning a 110kW pump station often face a common challenge: direct-on-line starting draws up to 6-8 times rated current, causing voltage dips that trip sensitive equipment and accelerate motor winding degradation. The Siemens 3RW4434-6BC44 SIRIUS soft starter solves this by providing controlled voltage ramp-up, reducing mechanical stress and electrical disturbances. With its inside-delta circuit capability, it delivers 110kW performance from a compact 170mm-wide frame—ideal for retrofits where panel space is at a premium.

Key Features and Technical Specifications
- Operating voltage: 200–460V AC (standard circuit), with -15%/+10% tolerance for stable performance on varying supplies.
- Control supply: 230V AC at 50/60Hz, ensuring compatibility with common industrial control circuits.
- Rated current: 113A at 40°C (standard) or 196A inside-delta; derates to 88A/152A at 60°C.
- Motor power: 55kW at 400V standard, 110kW at 400V inside-delta.
- Integrated thyristors and bridging contact system for smooth, wear-free switching.
- Adjustable current limitation and intrinsic device protection reduce downtime risk.
- Three NO auxiliary contacts and one changeover contact for flexible control integration.
- Screw terminals and busbar connections accommodate conductor sizes from 16 to 70mm².
- Operating temperature range up to 60°C; storage from -25°C to +80°C.
- IP00 protection class for panel-mounted installation.
The standout feature is the inside-delta circuit, which allows the soft starter to be rated for the phase current rather than line current, effectively doubling the motor power it can handle without increasing frame size. This is particularly valuable in retrofit projects where existing cabinet dimensions are fixed.
Applications and Use Cases
The 3RW4434-6BC44 excels in pump, fan, and compressor applications where controlled acceleration prevents water hammer, belt slip, and pressure surges. In a typical wastewater treatment plant, this soft starter ramps a 110kW centrifugal blower over 20 seconds, eliminating the mechanical shock of direct-on-line starting and extending bearing life. For conveyor systems, the adjustable current limitation ensures smooth material handling without product spillage. Its inside-delta capability is especially beneficial in retrofit scenarios where a larger motor must be controlled without upsizing the electrical room footprint.

Installation and Setup
Mount the soft starter vertically on a screw-fixed panel, maintaining clearances: 100mm above, 75mm below, and 5mm to the sides for heat dissipation. The unit can be tilted ±22.5° forward or backward and rotated ±90° for flexible alignment. Connect main conductors to the busbar terminals (16–70mm²) and control wires to the screw terminals (0.5–2.5mm²). Ensure the 230V AC control supply is within -15%/+10% tolerance. For inside-delta configuration, verify motor winding connections per Siemens documentation. The IP00 rating requires installation inside a protective enclosure.
Compatibility and Integration
The 3RW4434-6BC44 integrates seamlessly with Siemens SIRIUS 3RU overload relays and 3RT contactors. Its auxiliary contacts (3 NO, 1 CO) interface with PLCs and control systems for status monitoring and remote reset. The soft starter supports thermal resistor motor protection evaluation, allowing direct connection of PTC sensors. For network integration, the unit does not include a native fieldbus interface; wiring into PROFINET or EtherNet/IP networks may require an external gateway or connection module. Confirm cable and gateway compatibility with your supplier before commissioning.
Maintenance and Reliability
Regular inspection every 6–12 months is recommended, focusing on terminal tightness and heatsink cleanliness. The thyristors and bridging contact system are wear-free under normal operation, but environmental factors like dust and humidity can affect performance. Maintain panel temperature below 40°C to avoid derating; at 60°C, the current capacity drops by 22%. The integrated overload protection and fault display enable quick diagnostics, reducing mean time to repair. By preventing high inrush currents, the soft starter extends motor insulation life and reduces downtime costs—a key value proposition for continuous-process industries.
Product Support and Availability
Mronexus stocks the Siemens 3RW4434-6BC44 and ships worldwide from available inventory. As your one-stop sourcing base for genuine industrial automation parts, we offer competitive prices and fast delivery. Contact Mronexus for genuine industrial automation parts and technical support.
Unmatched Customer Service
- After Hours Shipping
- Real Time Order Tracking
- Flexible Delivery Options
- Intact Technical Supports