22C-B033H103 | Allen-Bradley PowerFlex 400 7.5 kW Drive RS-485
PLC
- Brand: Allen-Bradley
- Part Number:
22C-B033H103 - Availability: Ask for quote
Evaluate the Allen-Bradley 22C-B033H103 PowerFlex 400 AC drive: 7.5 kW, 200–240V 3-phase, built-in RS-485 with Modbus RTU, Metasys N2 and P1-FLN, IP20 plate mount. A reliable choice for fan and pump control, available from Mronexus with fast delivery from stock.
Product Details
Product Introduction: A Fan-and-Pump Drive Built for Reliable Flow Control
When specifying an AC drive for fan and pump duty, engineers need a unit that combines proven motor control with straightforward integration and long-term reliability. The Allen-Bradley 22C-B033H103 from the PowerFlex 400 series is a 7.5 kW (10 HP) adjustable-frequency drive designed specifically for variable-torque applications. It accepts 200…240V AC three-phase input and delivers up to 33 A continuous output, making it a solid fit for centrifugal loads in HVAC, water treatment and process cooling systems.
This catalog number is built around a heatsinkless plate-mount design (IP20 / NEMA/UL Type Open), which allows the drive to be integrated into an enclosure or panel where space and heat management are carefully planned. The integral fixed keypad provides local configuration and monitoring, while the built-in RS-485 port supports Modbus RTU, Metasys N2 and P1-FLN protocols for direct connection to building automation and control networks.
As a genuine Allen-Bradley product, the 22C-B033H103 is part of a drive family rated from 2.2 to 250 kW, so it benefits from a consistent programming environment and a well-documented parameter set. Mronexus supplies this unit as part of its one-stop sourcing base for PLC, HMI, servo, sensor and circuit breaker needs, with worldwide shipping and fast delivery from stock.

Key Features and Technical Specifications
- Rated output power: 7.5 kW (10 HP) at 33 A continuous, suitable for fan and pump loads.
- Input voltage: 200…240V AC, 3-phase, ±10% tolerance, 48…63 Hz.
- Output voltage and frequency: 0…230V three-phase output, 0…320 Hz programmable.
- Control method: Sinusoidal PWM, Volts/Hertz with slip compensation for ±1% speed regulation.
- Overload capability: 110% for up to 1 minute; 180% hardware current limit.
- Operating temperature: -10…+50 °C (14…122 °F) without derating for IP20 open drives.
- Communication: Built-in RS-485 DSI port supporting Modbus RTU, Metasys N2 and P1-FLN.
- I/O: 7 digital inputs, 2 analog inputs, 2 Form C relay outputs, 1 opto output, 2 analog outputs.
- Enclosure: IP20 / NEMA/UL Type Open, heatsinkless plate mount, Frame C.
- Dimensions (H×W×D): 260 × 130 × 180 mm; weight 3.21 kg.
The built-in PID control loop and auxiliary motor control for up to three additional motors are particularly valuable in pump systems, where they enable staged operation and energy savings without an external controller. The drive also includes DC injection braking, programmable stop modes and a 100 ms power ride-through to maintain operation through short supply disturbances.
Applications and Use Cases
The 22C-B033H103 is engineered for variable-torque loads, and its feature set maps directly to common fan and pump applications. In HVAC systems, the drive can modulate supply and return fans based on duct pressure or temperature, using the built-in PID loop to maintain setpoints while reducing energy consumption at partial loads. For chilled-water and process pumps, the auxiliary motor control allows a single drive to manage a lead pump and up to three lag pumps, simplifying panel design and reducing component count.
In water treatment and irrigation, the drive’s Modbus RTU and Metasys N2 connectivity supports integration with SCADA and building management systems, enabling remote monitoring and control. The IP20 open enclosure is well suited for installation inside a larger control cabinet, where the plate-mount design helps manage heat dissipation. Because the drive is rated for 50 °C ambient without derating, it can be applied in mechanical rooms and industrial spaces where temperatures are elevated but controlled.
When evaluating this drive for a replacement or new project, consider the load type and duty cycle. The 110% overload rating for one minute covers most centrifugal fan and pump starting requirements, but positive-displacement loads or high-inertia fans may require a larger frame size or additional braking provisions.

Installation and Setup
Mounting the 22C-B033H103 requires a flat, thermally conductive surface because the drive relies on plate conduction rather than an integral heatsink. Ensure the enclosure provides adequate ventilation or cooling to maintain the surrounding air temperature within the -10…+50 °C range. The drive must be installed with branch short-circuit protection; the recommended input fuse is 45 A (UL Class J, CC, T or BS88), and a 140M-F8E-C45 manual self-protected combination motor controller is specified for this rating. A 100-C43 or 100-E40 contactor is recommended for line isolation.
For EMC compliance to EN 61800-3, an external 22-RF034-CS line filter is required because the drive is supplied unfiltered. Wiring should follow the published guidelines for shielding and grounding. The RS-485 port uses an RJ45 connector with only pins 4 and 5 active; use shielded twisted-pair cable and terminate the network at both ends. For multi-drop Modbus RTU networks, set the baud rate (default 9600 bit/s) and node address (default 100) via parameters C103 and C104. If the drive is installed in a Frame C enclosure and a communication adapter is added, a 22C-CCC adapter cover is required.
Maintenance and Reliability
Routine maintenance focuses on environmental conditions and thermal management. Inspect the mounting surface and enclosure filters regularly to prevent dust buildup, which can raise internal temperatures and reduce service life. Verify that the ambient atmosphere is free of corrosive gases, vapors or dust, as these are explicitly prohibited by the drive’s specifications. The cooling fan is the primary wear component; check for unusual noise or reduced airflow during scheduled inspections.
Because the drive operates at 97.5% efficiency at rated load, heat generation is moderate but still requires consideration in sealed enclosures. The published power dissipation for this rating is 359 W under IP20 open conditions, so enclosure cooling must be sized accordingly. The 100 ms power ride-through and 0.5 s logic control ride-through help the drive ride through short supply dips without nuisance trips, contributing to reliable operation in facilities with variable power quality.
Compatibility and Integration
The 22C-B033H103 integrates with control systems through its built-in RS-485 port, which supports Modbus RTU, Metasys N2 and P1-FLN. This makes it suitable for direct connection to building automation systems and PLCs without additional communication hardware. For other networks, the 22-COMM family of adapters provides BACnet MS/TP, DeviceNet, EtherNet/IP, PROFIBUS DP, ControlNet and LonWorks connectivity. When using fieldbus adapters, confirm cable and gateway requirements with the supplier, as wiring into such networks may require an external gateway or connection module.
The drive’s analog and digital I/O allow interfacing with pressure transmitters, flow meters and damper actuators. The two analog inputs accept 0…10V or 4…20 mA signals, and the two Form C relay outputs can be programmed for fault, run or alarm indication. For systems requiring encoder feedback, note that the PowerFlex 400 does not provide an encoder input; applications needing closed-loop vector control should consider a different drive family.
FAQ
Q: What is the input voltage and power rating of the 22C-B033H103?
A: The drive accepts 200…240V AC three-phase input with ±10% tolerance and delivers 7.5 kW (10 HP) at 33 A continuous output.
Q: Which communication protocols are built in?
A: The built-in RS-485 port supports Modbus RTU, Metasys N2 and P1-FLN. Optional 22-COMM adapters add BACnet, DeviceNet, EtherNet/IP, PROFIBUS DP, ControlNet and LonWorks.
Q: What is the operating temperature range without derating?
A: For IP20 open drives, the range is -10…+50 °C (14…122 °F). Above 1000 m altitude, derating applies at 3% per 305 m.
Q: Is an external EMC filter required?
A: Yes, for EN 61800-3 compliance, the 22-RF034-CS line filter is required because the drive is supplied unfiltered (emission class 0).
Product Support and Availability
The 22C-B033H103 is an active catalog number in the Allen-Bradley PowerFlex 400 family, with no discontinuation published. Mronexus maintains stock of genuine industrial automation parts and offers fast delivery from stock with worldwide shipping. For technical documentation, refer to publications 22C-TD001G-EN-P and 22C-UM001K-EN-E, or contact Mronexus for genuine industrial automation parts and application support.
Unmatched Customer Service
- After Hours Shipping
- Real Time Order Tracking
- Flexible Delivery Options
- Intact Technical Supports