Siemens 3RW4426-1BC44 SIRIUS soft starter: 77A, 37kW at 400V, inside-delta 133A/75kW. Reliable motor control with integrated protection. In stock at Mronexus.

Product Details

Product Introduction

In industrial motor control, the cost of unplanned downtime and premature equipment failure can quickly erode profitability. The Siemens 3RW4426-1BC44 SIRIUS soft starter addresses these challenges head-on, offering reliable, genuine performance for high-feature applications. Designed for three-phase motors, this soft starter provides smooth acceleration and deceleration, reducing mechanical stress and extending motor life. With a rated operating current of 77 A at 40°C and a power rating of 37 kW at 400 V AC, it delivers robust control for demanding applications. The inside-delta circuit configuration further enhances flexibility, supporting up to 133 A and 75 kW, making it a versatile choice for various motor sizes. As part of the SIRIUS family, this soft starter integrates seamlessly into existing systems, ensuring fast-delivery and value-for-money for your automation needs.

Figure 1: Front view of the Siemens 3RW4426-1BC44 industrial automation component showing its physical design and enclosure.

Key Features & Technical Specifications

  • Operating voltage: 200–460 V AC, with -15%/+10% tolerance for stable performance.
  • Rated current: 77 A at 40°C (68 A at 50°C, 59 A at 60°C) for thermal flexibility.
  • Power rating: 37 kW at 400 V AC standard circuit; 75 kW in inside-delta configuration.
  • Control supply voltage: 230 V AC at 50/60 Hz, ensuring compatibility with standard control circuits.
  • Integrated motor overload protection and thermal resistor evaluation for enhanced safety.
  • Adjustable current limitation to reduce stress on the motor and power supply.
  • Ambient temperature range: up to 60°C during operation, with derating above 40°C.
  • Dimensions: 170 x 192 x 270 mm (W x H x D), compact for panel mounting.
  • Communication: screw terminals for main and control circuits; optional PROFINET/EtherNet/IP via gateway.
  • Integrated bridging contact system and thyristors for reliable switching.

Each specification translates directly into cost savings: the wide voltage tolerance reduces the need for additional voltage conditioning equipment, while the high current rating at elevated temperatures minimizes derating requirements and cabinet cooling costs. The integrated protection features eliminate the need for separate overload relays, saving panel space and wiring expenses.

Applications & Use Cases

The 3RW4426-1BC44 is ideal for applications requiring controlled motor starting and stopping, such as pumps, fans, compressors, and conveyors. In a typical wastewater treatment plant, this soft starter can smoothly ramp up large pumps, preventing water hammer and reducing pipe stress—a common failure mode that leads to costly repairs. For HVAC systems, it minimizes mechanical wear on fan belts and bearings, extending service intervals and lowering maintenance costs. In manufacturing lines, the inside-delta circuit allows the same starter to handle larger motors without upgrading the electrical infrastructure, providing a cost-effective solution for expanding production capacity. The integrated motor overload protection and thermal resistor evaluation ensure reliable operation even under varying load conditions, reducing the risk of unexpected downtime and production losses.

Figure 2: Technical layout and connection details for the Siemens 3RW4426-1BC44 industrial automation component.

Installation & Setup

Proper installation is critical for maximizing the soft starter’s lifespan and performance. Mount the device vertically on a panel, ensuring the specified clearances: 100 mm above, 75 mm below, and 5 mm on each side for adequate heat dissipation. Use screw terminals for main and control connections; the box terminals accept conductor cross-sections from 2.5 to 70 mm², accommodating a wide range of cable sizes. For inside-delta configuration, follow the wiring diagram carefully to ensure correct phase connections. The control supply voltage is 230 V AC, 50/60 Hz; verify the control circuit voltage before energizing. The soft starter supports installation altitudes up to 5,000 m; for altitudes above 2,000 m, derate the current accordingly. Always adhere to local electrical codes and ensure proper grounding.

Maintenance & Reliability

The 3RW4426-1BC44 is designed for low maintenance, but regular inspections are recommended to ensure optimal performance. Check for tightness of screw terminals annually, as loose connections can cause overheating and increased energy losses. Inspect the cooling path and clean any dust accumulation, especially in environments with high particulate levels. The integrated thyristors and bridging contact system are solid-state components with no moving parts, reducing wear and tear. However, the bypass contactor (if used) should be inspected for contact wear every 100,000 operations. The soft starter’s ambient temperature rating of 60°C means it can operate in harsh environments, but derating above 40°C is necessary to avoid reduced lifespan. By following these guidelines, you can avoid costly unplanned downtime and extend the unit’s service life, ensuring genuine value-for-money.

Compatibility & Integration

The 3RW4426-1BC44 integrates seamlessly with Siemens SIRIUS control systems and third-party PLCs via its control terminals. For network integration, the soft starter does not include native fieldbus communication; however, it can be connected to PROFINET or EtherNet/IP networks using an external gateway or connection module. When wiring into such networks, confirm the appropriate gateway and cabling with your supplier to ensure compatibility. The auxiliary contacts (3 NO, 1 changeover) provide status feedback to control systems, enabling remote monitoring and diagnostics. The soft starter is also compatible with Siemens SIMOCODE and other motor management systems, allowing centralized control and data acquisition.

FAQ

Q: What is the maximum motor power this soft starter can handle?

A: In standard circuit at 400 V AC, it handles up to 37 kW; in inside-delta configuration, up to 75 kW. Always verify motor full-load current against the starter’s rating.

Q: Can I use this soft starter with a 60°C ambient temperature?

A: Yes, but derating is required: at 60°C, the rated current drops to 59 A (standard) or 102 A (inside-delta). Ensure proper ventilation and consider the derating curve.

Q: Does it support fieldbus communication like PROFINET?

A: Not natively; an external gateway is required for PROFINET or EtherNet/IP integration. Consult Mronexus for compatible gateways and wiring accessories.

Q: What type of motor protection is integrated?

A: It includes electronic motor overload protection, thermal resistor evaluation, and adjustable current limitation, reducing the need for additional protective devices.

Product Support & Availability

The Siemens 3RW4426-1BC44 is in stock and ready to ship from Mronexus. As your one-stop sourcing base for genuine industrial automation parts, we offer fast delivery and competitive prices. Contact Mronexus for genuine industrial automation parts and technical support.

Unmatched Customer Service

  • After Hours Shipping
  • Real Time Order Tracking
  • Flexible Delivery Options
  • Intact Technical Supports

Need a quote or technical support?

Send us your part numbers and we will get back within 24 hours.