The MTL4013 is a two-channel interface that lets safe-area loads be controlled by switches or proximity detectors in hazardous areas. It offers solid-state outputs, optional earth fault detection, and 5kHz operation.

Product Details

How Do You Reliably Control Safe-Area Loads from Hazardous-Area Switches?

In many process plants, the challenge is not just detecting a switch or proximity sensor in a hazardous area—it is doing so with a solution that is reliable, safe, and easy to integrate. The MTL4013 from MTL answers this challenge directly. This two-channel unit enables safe-area loads to be controlled by switches or proximity detectors located in Zone 0, IIC, T6 hazardous areas, or Div.1, Group A hazardous locations. It is also well-suited for use with positive displacement (PD) flowmeters and some turbine meters.

As a genuine MTL product, the MTL4013 is built for dependable performance in demanding industrial environments. At Mronexus, we supply genuine industrial automation parts at below-market prices, with worldwide shipping and fast delivery from stock. Whether you need a single unit or a complete bill of materials, Mronexus is your one-stop sourcing base for PLC, HMI, servo, sensor, and circuit breaker needs.

Figure 1: Front view of the MTL MTL4013 industrial automation component showing its physical design and enclosure.

Key Features and Technical Specifications

The MTL4013 offers a range of features designed for safety and reliability in hazardous-area signal interfaces. Below are the core technical parameters:

  • Number of channels: Two independent channels for flexible signal handling.
  • Input voltage to sensor: 7.0V – 9.0V dc from 1kΩ, compatible with NAMUR and DIN 19234 proximity detectors.
  • Output characteristics: Output on if >2.1mA (<2kΩ) in sensor circuit; output off if <1.2mA (>10kΩ); hysteresis 200µA (650Ω) nominal.
  • Operating frequency: dc to 5kHz, suitable for dynamic signals.
  • Maximum off-state voltage: 35V; maximum off-state leakage current: 10µA.
  • Maximum on-state current: 50mA; maximum on-state voltage drop: [1 + (0.1 x current in mA)] V.
  • Power requirement: 47.5mA at 24V dc, 45mA at 20V dc, 50mA at 35V dc.
  • Power dissipation: 1.15W at 24V, 1.75W at 35V.
  • Isolation: 250V ac between safe and hazardous area circuits.
  • Safety description per channel: 10.5V, 800Ω, 14mA; FM entity parameters: Voc = 10.5V dc, Isc = 14mA, Ca = 2.4µF, La = 165mH.
  • LED indicators: Amber LED per channel (ON when output circuit is closed); green LED for power indication.
  • Earth fault detection: Optional, via connection to MTL4220 earth leakage detector; fault on either line is proclaimed while the unit continues working.

One standout feature is the ‘no-fail’ earth fault protection. When connected to an MTL4220 earth leakage detector, the MTL4013 can detect earth faults on either line without interrupting operation. This is particularly valuable in continuous processes where downtime is costly. Note that if isolation between the two channels is required, separate earth leakage detectors are needed.

Applications and Use Cases

The MTL4013 is ideal for applications where switches or proximity detectors are located in hazardous areas and need to interface with safe-area control systems. Common use cases include:

  • Level detection using NAMUR proximity sensors in Zone 0 or Div.1 areas.
  • Flow measurement with positive displacement (PD) flowmeters and turbine meters, where the MTL4013’s frequency response up to 5kHz ensures accurate pulse transmission.
  • Valve position monitoring in hazardous locations, with the amber LED providing clear status indication.
  • General-purpose switch input interfacing for safety-critical loops, leveraging the unit’s earth fault detection capability.

In a typical PD flowmeter application, the MTL4013 reliably transmits pulses from the hazardous area to a safe-area counter or PLC, maintaining signal integrity even in the presence of earth faults.

Figure 2: Technical layout and connection details for the MTL MTL4013 industrial automation component.

Installation and Setup

Installing the MTL4013 is straightforward for engineers familiar with DIN-rail mounted interfaces. The unit is designed for backplane or standalone mounting, with clearly marked terminals. Key installation considerations:

  • Ensure power supply is within the specified range (20–35V dc) and observe polarity on terminals 13 (–ve) and 14 (+ve).
  • Connect hazardous-area switches or proximity detectors to input terminals 1–2 (channel 1) and 4–5 (channel 2), observing the voltage and current limits for NAMUR sensors.
  • For earth fault detection, link terminals 3 and 6 to an MTL4220 earth leakage detector as required.
  • Outputs are available on terminals 7–9; each output is Zener-diode protected against inductive loads, but external suppression may be needed for highly inductive loads.
  • Verify LED indicators: green for power, amber for output status.

Always refer to the official MTL4013 datasheet and relevant installation standards for detailed wiring diagrams and hazardous-area certification requirements.

Maintenance and Reliability

The MTL4013 is designed for long-term reliability with minimal maintenance. Regular inspection intervals should be established based on environmental conditions. Key maintenance points:

  • Check LED indicators periodically to confirm power and output status.
  • Inspect terminals for tightness and corrosion, especially in harsh environments.
  • Test earth fault detection functionality if connected to an MTL4220.
  • Ensure the operating temperature remains within the specified range (refer to datasheet).

By choosing genuine MTL parts like the MTL4013, you benefit from reliable performance and reduced downtime, which translates to cost savings over the lifecycle of your plant.

Compatibility and Integration

The MTL4013 is compatible with NAMUR and DIN 19234 proximity detectors, as well as mechanical switches. It integrates seamlessly with safe-area control systems such as PLCs and DCS via its solid-state outputs. The unit’s 250V ac isolation between safe and hazardous areas ensures safe signal transfer.

Integration Note: When wiring into fieldbus networks (e.g., PROFINET, EtherNet/IP), an external gateway or connection module may be required. Confirm cables and gateways with your supplier to ensure proper integration.

Frequently Asked Questions

Q: What is the maximum operating frequency of the MTL4013?

A: The MTL4013 operates from dc to 5kHz, making it suitable for pulse outputs from PD flowmeters and turbine meters.

Q: Can the MTL4013 detect earth faults?

A: Yes, optional earth fault detection is available by connecting terminals 3 and 6 to an MTL4220 earth leakage detector. The unit continues working even when a fault is proclaimed.

Q: What is the power supply requirement for the MTL4013?

A: The unit requires 24V dc nominal (20–35V dc range) with a current consumption of 47.5mA at 24V dc.

Q: Is the MTL4013 suitable for Zone 0 hazardous areas?

A: Yes, switches can be located in Zone 0, IIC, T6 hazardous areas, and proximity detectors in Zone 0, IIC, T4–6 if suitably certified.

Q: What is the output current rating?

A: Each output can handle a maximum on-state current of 50mA, with a maximum off-state voltage of 35V.

Product Support and Availability

The MTL4013 is in stock and ready to ship from Mronexus. As a trusted distributor of genuine industrial automation parts, we offer fast delivery worldwide and competitive pricing. Contact Mronexus for genuine industrial automation parts and experience our one-stop sourcing approach for all your automation needs.

Unmatched Customer Service

  • After Hours Shipping
  • Real Time Order Tracking
  • Flexible Delivery Options
  • Intact Technical Supports

Need a quote or technical support?

Send us your part numbers and we will get back within 24 hours.

Contact Us