The BMXNOR0200 is a Modicon X80 RTU serial module with RS232/RS485 and Modbus RTU, designed for distributed I/O in M340 and M580 systems.
Product Details
Product Introduction
In distributed control systems, reliable remote I/O connectivity is critical to maintaining operational efficiency. The BMXNOR0200 from Schneider Electric is a Modicon X80 RTU serial module designed to provide robust serial communication for remote terminal units. As part of the Modicon X80 series, this module offers a compact, reliable solution for extending I/O in industrial automation architectures.
Engineered for seamless integration with Modicon M340 and M580 controllers, the BMXNOR0200 delivers Modbus RTU communication over RS232/RS485, making it an ideal choice for distributed I/O applications. Its active lifecycle status ensures long-term availability and support, backed by Schneider Electric’s reputation for quality and reliability.

Key Features & Technical Specifications
- Communication Protocol: Modbus RTU over 1× RS232/RS485 serial port for flexible integration.
- Application Channels: 1 channel for remote terminal unit (RTU) functionality.
- Supply Voltage: 24 V DC via backplane, with power consumption of 1.9 W.
- Bus Current: 80 mA @ 24 V DC, ensuring efficient power usage.
- Operating Temperature: 0°C to +60°C, suitable for standard industrial environments.
- Storage Temperature: -25°C to +70°C for safe storage.
- Relative Humidity: 5% to 95% (non-condensing) for reliable operation in varying conditions.
- Protection Rating: IP20, providing basic protection against solid objects.
- Dimensions (H×W×D): 100 × 28 × 93 mm, compact design for space-constrained panels.
- Weight: 0.15 kg, lightweight for easy installation.
- Backplane: X-bus for secure and stable connection.
- Slot Occupation: 1 slot, optimizing rack space.
The BMXNOR0200 stands out for its integrated RTU functionality, enabling distributed I/O architectures without the need for additional communication hardware. This reduces complexity and cost in remote monitoring and control applications.
Comparison with Similar Modules
When selecting a serial communication module for Modicon X80 platforms, engineers often compare the BMXNOR0200 with other options. The table below highlights key differences:
- BMXNOR0200: RTU serial module, Modbus RTU, RS232/RS485, 1 channel, 1.9 W.
- BMXNOM0200: Serial link module, Modbus RTU/ASCII, RS232/RS485, 2 channels, 1.5 W.
- BMXNOE0100: Ethernet TCP/IP module, 1 port, 10/100 Mbps, 2.5 W.
The BMXNOR0200 is specifically designed for RTU applications, offering a dedicated solution for distributed I/O with Modbus RTU. Its power consumption and single-channel design make it a cost-effective choice for point-to-point serial communication.

Applications & Use Cases
The BMXNOR0200 excels in applications requiring reliable remote I/O connectivity. In water treatment plants, it enables monitoring and control of remote pumps and valves via Modbus RTU, ensuring efficient operation. In manufacturing lines, it facilitates communication with legacy serial devices, bridging the gap between modern PLCs and older equipment. For oil and gas installations, the module’s robust design ensures dependable performance in harsh environments. Additionally, in building automation, it integrates HVAC and lighting controls into a central management system, enhancing energy efficiency.
Installation & Setup
Installing the BMXNOR0200 is straightforward. It occupies one slot on the X-bus backplane of Modicon M340 or M580 racks. Ensure the system is powered off before insertion. Connect the RS232/RS485 cable to the built-in port, and configure the module in the PLC programming software. The module supports hot-swap in compatible racks, minimizing downtime during replacement.
Maintenance & Reliability
The BMXNOR0200 is designed for long-term reliability with minimal maintenance. Regular inspection of connections and environmental conditions is recommended. Operating within the specified temperature and humidity ranges ensures optimal performance. The module’s low power consumption reduces heat generation, extending component life. For maximum uptime, keep spare modules on hand—Mronexus stocks genuine BMXNOR0200 units for fast delivery.
Compatibility & Integration
The BMXNOR0200 is compatible with Modicon M340 and M580 PLCs via the X-bus backplane. It communicates using Modbus RTU, a widely supported protocol in industrial automation. For integration into larger networks, such as those using PROFINET or EtherNet/IP, an external gateway may be required. Consult with Mronexus for assistance with cables and gateways to ensure seamless integration.
Frequently Asked Questions
Q: What is the operating temperature range of the BMXNOR0200?
A: The BMXNOR0200 operates within 0°C to +60°C, suitable for standard industrial environments.
Q: Can the BMXNOR0200 be used with both M340 and M580 PLCs?
A: Yes, it is part of the Modicon X80 shared I/O platform, compatible with both M340 and M580 controllers.
Q: What communication protocol does the BMXNOR0200 support?
A: It supports Modbus RTU over its RS232/RS485 serial port, enabling integration with various Modbus devices.
Q: What is the power consumption of the BMXNOR0200?
A: The module consumes 1.9 W and draws 80 mA from the 24 V DC backplane supply.
Product Support & Availability